MODEL_2433R
AC clamp meter 40/400mA/400A with selectable frequency

- Frequency response
- 20Hz to 1kHz [40Hz to 1kHz:400A]
- Response time
- Approx. 2 seconds
- Conductor size
- φ 40mm max.
- Dimension
- 185(L) × 81(W) × 40(D)mm
AC clamp meter 40/400mA/400A with selectable frequency
Kyoritsu MODEL 2433R clamp meter for AC current measurement up to 400 A, with three ranges 40/400mA/400A and a frequency selector switch to eliminate the effect of harmonics.
Kyoritsu MODEL 2433R. clamp meter for AC current measurement. This instrument in the clamp meter category offers three ranges, 40 mA, 400 mA and 400 A.
Main characteristics. Minimum resolution of 0.01 mA, response time of approximately 2 seconds and maximum conductor size of 40 mm. Weight is approximately 270 g including battery.
Accuracy. In AC 50/60 Hz, accuracy is ±1% of reading ±5 digits on the 40/400 mA ranges and on the 0 to 300 A range, and ±2% of reading on the 300.1 to 399.9 A range. In WIDE mode, the frequency response is 20 Hz to 1 kHz (40 Hz to 1 kHz for 400 A), with accuracy of ±2.5% of reading ±10 digits on the 40/400 mA ranges and on the 0 to 300 A range, and ±5% of reading on the 300.1 to 399.9 A range.
Frequency selector. The frequency selector switch eliminates the effect of harmonics on the measurement.
Compatibility and magnetic influence. The effect of an external stray magnetic field is approximately 10 mA AC in proximity to a 15 mm conductor carrying 100 A AC.
Power and environment. The instrument is powered by two R03 (DC 1.5 V) batteries. It complies with IEC 61010-1 CAT III 300 V, pollution degree 2, and with IEC 61010-2-032. Dimensions: 185 × 81 × 40 mm.
Typical uses. AC current measurement on conductors up to 40 mm in diameter, particularly where harmonics are present. Supplied with carrying case 9097, two R03 batteries and an instruction manual.
No published question about this part yet. Questions are reviewed before publication.
Every characteristic recorded for MODEL_2433R, with where it comes from. Use the filters to find one quickly.
| Characteristic | Value |
|---|---|
| Response time | Approx. 2 seconds |
| AC A (50/60Hz) | 40/400mA/400A; ±1%rdg±5dgt (40/400mA); ±1%rdg±5dgt (0 to 300A); ±2%rdg (300.1 to 399.9A) |
| AC A (WIDE) | 40/400mA/400A; ±2.5%rdg±10dgt [20Hz to 1kHz] (40/400mA); ±2.5%rdg±10dgt [40Hz to 1kHz] (0 to 300A); ±5%rdg [40Hz to 1kHz] (300.1 to 399.9A) |
| Accessories | 9097 (Carrying Case); R03 (1.5V) × 2; Instruction Manual |
| Applicable Standards | IEC 61010-1 CAT III 300V Pollution Degree 2; IEC 61010-2-032 |
| Conductor size | φ 40mm max. |
| Dimension | 185(L) × 81(W) × 40(D)mm |
| Effect of External Stray Magnetic Field | Approx. 10mA AC in proximity to a 15mm; conductor carrying 100A AC |
| Frequency response | 20Hz to 1kHz [40Hz to 1kHz:400A] |
| Power Source | R03 (DC1.5V) × 2 |
| Three ranges | 40/400mA/400A |
| Weight | Approx. 270g (including battery) |
No specification matches.
Last verification : 2026-11-03
Official documents and the technical data recorded for MODEL_2433R. For a missing document or a specific revision, our experts send it to you.
Kyoritsu MODEL 2433R clamp meter for AC current measurement up to 400 A, with three ranges 40/400mA/400A and a frequency selector switch to eliminate the effect of harmonics.
| Parameter | Value |
|---|---|
| Response time | Approx. 2 seconds |
| AC A (50/60Hz) | 40/400mA/400A; ±1%rdg±5dgt (40/400mA); ±1%rdg±5dgt (0 to 300A); ±2%rdg (300.1 to 399.9A) |
| AC A (WIDE) | 40/400mA/400A; ±2.5%rdg±10dgt [20Hz to 1kHz] (40/400mA); ±2.5%rdg±10dgt [40Hz to 1kHz] (0 to 300A); ±5%rdg [40Hz to 1kHz] (300.1 to 399.9A) |
| Accessories | 9097 (Carrying Case); R03 (1.5V) × 2; Instruction Manual |
| Applicable Standards | IEC 61010-1 CAT III 300V Pollution Degree 2; IEC 61010-2-032 |
| Conductor size | φ 40mm max. |
| Dimension | 185(L) × 81(W) × 40(D)mm |
| Effect of External Stray Magnetic Field | Approx. 10mA AC in proximity to a 15mm; conductor carrying 100A AC |
| Frequency response | 20Hz to 1kHz [40Hz to 1kHz:400A] |
| Power Source | R03 (DC1.5V) × 2 |
| Three ranges | 40/400mA/400A |
| Weight | Approx. 270g (including battery) |
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
AC clamp meter 40/400mA/400A with selectable frequency

KEW 2413R

KAIWEETS HT208D 1000A AC/DC Inrush Clamp Meter

KAIWEETS KC602 Smart Digital Clamp Meter

Describe your application and constraints in a request.
What is recorded about the regulatory status and the life of this part.
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
| Current status | Status not stated |
| Key dates | Not recorded |
| Manufacturer part number | MODEL_2433R |
| Manufacturer | Kyoritsu |
Clamp Meters
AC clamp sensor for digital multimeter · Ref. : KEW_8161
Price on request
Clamp Meters
2-Phase Clamp Voltammeter with Phase Diagram Display · Ref. : UT265B
Price on request
Clamp Meters
AC DC Clamp Digital Multimeter 750 V 600 A · Ref. : DMC-100
Price on request
Clamp Meters
AC clamp meter with 500 mV output for KEW 5050 leakage · Ref. : KEW_8178
Price on request