MODEL 5406A – RCD tester for standard, selective, AC and A breakers

RCD tester for standard, selective, AC and A breakers

Installation and Earth Testers

  • 10/20/30/200/300/500mA
  • 1000ms, 200ms (×5)
  • ±0.6%rdg±4dgt
  • 1ms
Manufacturer part number
MODEL_5406A
Manufacturer
Kyoritsu
Rated Tripping Current
10/20/30/200/300/500mA
Trip Current Duration
1000ms, 200ms (×5)

The Kyoritsu MODEL 5406A is an RCD tester that checks tripping time and tripping current of standard, selective, AC and A residual current breakers. It complies with IEC 61557.

Product overview

Kyoritsu MODEL 5406A RCD tester. The Kyoritsu MODEL 5406A is an RCD tester for checking electrical installations. It measures the tripping time and tripping current of residual current devices.

Main characteristics. The tester uses a custom microprocessor and constant current source circuitry, so that a fluctuating mains voltage does not affect measurement accuracy. Trip time accuracy is ±0.6%rdg ±4dgt, with a lowest resolution of 1 ms. Rated tripping currents are 10, 20, 30, 200, 300 and 500 mA, with trip current durations of 1000 ms and 200 ms (×5). Fault condition settings include × 1/2, × 1, × 5, × DC and AUTO RAMP. A 0 and 180 degree phase angle switch permits quick tests and consistent readings.

Tests and wiring check. The MODEL 5406A tests standard, selective, AC and A (DC sensitive) breakers. Three LEDs indicate the correct wiring status, and a visual indication shows reversed phase and neutral wiring at the socket. The tripping time is shown on a large digital readout.

Power, environment and standards. It operates on 230V +10 to 15% (195 to 253V) 50Hz. Its rating is IP54. It complies with IEC 61557-1 and -6, IEC 61010-1 (CAT III 300V, pollution degree 2), IEC 61010-2-031 and IEC 60529. Dimensions: 167 × 186 × 89 mm; weight approx. 800 g.

Accessories. The tester is supplied with a molded plug test lead, a shoulder strap (9121), a cord case (9147) and the instruction manual. Distribution board test leads (7121B) are available as an optional accessory. The instruction manual is offered in several languages, including English.

Use. This tester suits the maintenance and verification of electrical installations fitted with residual current devices. The product is available on quotation from Atlas Electronics.

See all specifications

Highlights

  • Dimension: 167(L) × 186(W) × 89(D)mm
  • Lowest Resolution: 1ms
  • Optional Accessories: 7121B (Distribution board test leads)
  • Rated Tripping Current: 10/20/30/200/300/500mA
  • Test of a large kind of RCDs: Standard, Selective, AC and A(DC sensitive breakers)
  • Trip Current Duration: 1000ms, 200ms (×5)

Technical questions

Ask a question

No published question about this part yet. Questions are reviewed before publication.