MODEL 6020/6030 – Multifunction installation tester with earth resistance test

Multifunction installation tester with earth resistance test

Installation and Earth Testers

  • 0-40º C
  • 1mA DC +20%-0%
  • 1.3mA DC approx.
  • General
Manufacturer part number
MODEL_6020_6030
Manufacturer
Kyoritsu
Operating Temperature Range
0-40º C
Rated test current
1mA DC +20%-0%

The Kyoritsu MODEL 6020/6030 is a multifunction installation tester for measuring insulation resistance, earth resistance and AC voltage, and checking phase sequence.

Product overview

Overview. The Kyoritsu MODEL 6020/6030 multifunction installation tester is a measuring instrument for verifying electrical installations, with insulation, earth resistance, AC voltage and phase checks. The manufacturer lists this product as discontinued. Main characteristics — True RMS sensing, 3 1/2 digit (1999 count) large LCD display, automatic power-off after about 30 minutes without button presses, display back-light and illuminated test probes. Water resistance IP57 according to IEC 60529. Measuring ranges are insulation resistance from 0 to 199.9 MΩ in three ranges, earth resistance from 0 to 1999 Ω in two ranges and AC voltage from 0 to 600 V. Connectivity and accessories — Test leads are stored in a cord reel module. The MODEL 6020 offers test voltages of 125 V, 250 V and 1000 V, the MODEL 6030 offers 250 V, 500 V and 1000 V. An LED phase check indicates correct or reversed phase sequence and open phase for 100 to 600 V AC. Optional accessories include the 2417 water proof leakage clamp meter and the 9080 aluminum carrying case. Power and environment — Powered by 1.5 V LR6 alkaline batteries, 8 for the main body and 1 for the probe, operating temperature range 0 to 40 °C, safety standard IEC 61010-1 CAT III 600 V, pollution degree 2. Typical uses — Inspection and verification of electrical installations, measurement of earth electrode and auxiliary earth spike resistance, insulation testing of circuits. Integration — Delivered with all accessories in a single carrying case. Available on quotation from Atlas Electronics.

See all specifications

Highlights

  • Display: 3 1/2(1999)digit large LCD
  • Earth Resistance Test Specifications: Earth Resistance Test Specifications
  • General: General
  • Input Impedance: 2M&Omega
  • Insulation Test Specifications: Insulation Test Specifications
  • Measuring Method: By constant current inverter 820Hz approx. 2mA approx.

Good to know before integrating

  • Thermal: rated operating range 0-40º C — check it against the installation environment.

Technical questions

Ask a question

No published question about this part yet. Questions are reviewed before publication.

Request a quote