| Accessories | 7141B (Voltage test lead set),; 7148 (USB Cable),; 7170 (Power cord),; 8307 (Compact Flash card 128MB),; 8319 (CF Card reader),; 9125 (Carrying bag),; PC Software, Batteries × 6, Quick manual |
| Accuracy | ±0.3%rdg±0.2%f.s. (sine wave, 45 - 65Hz) |
| Activa power accuracy | ±0.5%rdg±0.2%f.s. + Accuracy of Clamp sensor; (Power factor 1, Sine wave, 45 - 65Hz) |
| Allowable input | 10 - 110% of each range |
| CF card Interface | Compact flash card; (Standard type 32 / 64 / 128 / 256 / 512MB / 1 / 2 / 4 / 8GB); *The CF card larger than 2GB is usable, however, the possible; stored size will be limited to 2GB. For example, when the CF; card of 4GB or 8GB is used, the maximum stored size will be 2GB. |
| Consists of:; MODEL 6300 × 1; MODEL 8124(Φ 68) × 3 | Consists of:; MODEL 6300 × 1; MODEL 8124(Φ 68) × 2 |
| Consists of:; MODEL 6300 × 1; MODEL 8125(Φ 40) × 3 | Consists of:; MODEL 6300 × 1; MODEL 8125(Φ 40) × 2 |
| Consists of:; MODEL 6300 × 1; MODEL 8126(Φ 40) × 3 | Consists of:; MODEL 6300 × 1; MODEL 8126(Φ 40) × 2 |
| Consists of:; MODEL 6300 × 1; MODEL 8127(Φ 24) × 3 | Consists of:; MODEL 6300 × 1; MODEL 8127(Φ 24) × 2 |
| Consists of:; MODEL 6300 × 1; MODEL 8128(Φ 24) × 3 | Consists of:; MODEL 6300 × 1; MODEL 8128(Φ 24) × 2 |
| Dimension | 175(L)×120(W)×65(D) mm |
| Display ranges | 5 - 120% of each range |
| Display update period | 1 second |
| Effect of power factor | Active power : ±1.0% rdg cos θ =±0.5 (PF=1) |
| Frequency meter accuracy | ±3dgt |
| Frequency meter range | 40 - 70Hz |
| Integration time for; recording function | 1/2/5/10/15/20/30 Seconds 1/2/5/10/15/20/30/60 Minutes |
| Measurements and; parameters | Voltage, Current, Active power, Apparent power, Reactive power,; Active energy, Apparent energy, *Reactive energy,; Power factor (cos θ ), Neutral current, Frequency meter. |
| MODEL 6300-01 | MODEL 6300-02 |
| MODEL 6300-03 | MODEL 6300-04 |
| MODEL 6300-05 | MODEL 6300-06 |
| MODEL 6300-07 | MODEL 6300-08 |
| MODEL 6300-09 | MODEL 6300-10 |
| Operating temperature; and humidity ranges | 0 - +50º C, less than 85% RH (without condensation) |
| Optional Accessories | 8124,8125,8126,8127,8128 (Load Current Clamp Sensor).; 8129/8130 (Flexible Clamp Sensor).; 8312 (Power supply adaptor); 8322 (Compact flash card 256MB); 8323 (Compact flash card 1GB); 9132 (Carrying case with magnet); Wide range of clamp sensor up to 1000A on request. |
| Over load protection | Voltage : 720V AC rms; Current : 600A AC rms (with Clamp sensor MODEL 8125) |
| PC communication; Interface | USB |
| Power consumption | 10VA (MAX) |
| Power supply | AC Line : 100 - 240V±10% (50/60Hz); DC Battery 9V : LR6×6(Battery life approx. 7h) |
| Product Catalog | MODEL 6300 Product Catalog (English)(477.53 KB) |
| Quick Manual | MODEL 6300 Quick Manual (English)(2.02 MB) MODEL 6300 Quick Manual (Spanish)(2.00 MB) |
| Ranges [RMS] | 150 / 300 / 600V (CF: 2.5 or less) |
| Safety Standard | IEC 61010-1 CAT III 600V |
| Storage temperature; and humidity ranges | -20 - +60º C, less than 85% RH (without condensation) |
| Weight | Approx. 800g (including batteries) |
| Wiring connections | 1P 2W, 3P 4W, 3P 3W, 1P 3W |