DN750MM
Doppler ultrasonic flow meter, clamp-on

- Operating Temperature
- -20℃ to +60℃
- Flow velocity range
- 0.05- 12 m/s
- Pipe diameter range
- 40- 4 000 mm
- Accuracy
- 0.5% -- 2.0% F.S.
Doppler ultrasonic flow meter, clamp-on
Lanry DF6100-EC Doppler ultrasonic flow meter with clamp-on transducers, designed to measure the volumetric flow of liquids containing air bubbles or suspended solids in a full closed conduit.
Lanry DF6100-EC. The Lanry DF6100-EC wall-mounted Doppler ultrasonic flow meter measures the volumetric flow of liquids in a closed, full conduit, provided the liquid contains a certain amount of air bubbles or suspended solids.
Main characteristics. Flow velocity range from 0.05 to 12 m/s and pipe diameter range from 40 to 4 000 mm. Accuracy of 0.5% to 2.0% of full scale, repeatability of 0.2% of reading and resolution of 0.25 mm/s. Clamp-on transducers, installable without shutting down the pipe flow.
Display and configuration. 2-line by 8-character LCD, with rate or 8-digit resettable totalizer, 4-button keypad and units user-configurable in English and metric.
Interfaces and connectivity. 4-20mA, relay and OCT outputs.
Power and environment. AC 85-265V or DC 24V/500mA power supply. Operating temperature from -20°C to +60°C, IP66 protection according to EN60529, fiberglass housing.
Typical use. Flow measurement of liquids in pipelines, including industrial wastewater, with signal transmission to a supervision system through the 4-20mA output.
Available on quotation from Atlas Electronics.
No published question about this part yet. Questions are reviewed before publication.
Every characteristic recorded for DN750MM, with where it comes from. Use the filters to find one quickly.
| Characteristic | Value |
|---|---|
| Response time | 2-60s for optional |
| Accuracy | 0.5% -- 2.0% F.S. |
| Cable Length | Std: 10m |
| Communication | 4-20mA, Relay and OCT output |
| Degree of protection | IP66 according to EN60529 |
| Display | 2 line × 8 characters LCD, 8-digit rate or 8-digit total (resettable) |
| Enclosure Type | Wall-mounted |
| Flow velocity range | 0.05- 12 m/s |
| Housing Material | Fiberglass |
| Keypad | 4 pcs buttons |
| Liquid Types Supported | Liquids containing 100ppm of reflectors and at least 20% of the reflectors are larger than 100 micron. |
| Material of transducer | Aluminum for standard temp.sensor and peek for high temp.sensor |
| Measurement Principle | Doppler ultrasonic |
| Next | wetted type stainless steel insertion ultrasonic flow meter wall mounting |
| Operating Temperature | -20℃ to +60℃ |
| Pipe diameter range | 40- 4 000 mm |
| Power supply | AC: 85-265V DC: 24V/500mA |
| Previous | Doppler Pipeline Ultrasonic Flow Meter for insdutrial wastewater |
| Rate | Rate and Velocity Display |
| Repeatability | 0.2% of reading |
| Resolution | 0.25mm/s |
| Size | 244(h)*196(w)*1 1 4(d)mm |
| Suited Liquid Temperature | Std. Temp.: -35℃~85℃ for short periods up to 120℃ |
| Totalized | gallons, ft³, barrels, lbs, liters, m³,kg |
| Transducer Size | 60(h)*34(w)*3 2 (d)mm |
| Transducers Type | Clamp-on |
| Units | User Configured (English and Metric) |
| Weight | 2.4kg |
No specification matches.
Last verification : 2026-11-03
Official documents and the technical data recorded for DN750MM. For a missing document or a specific revision, our experts send it to you.
Lanry DF6100-EC Doppler ultrasonic flow meter with clamp-on transducers, designed to measure the volumetric flow of liquids containing air bubbles or suspended solids in a full closed conduit.
| Parameter | Value |
|---|---|
| Response time | 2-60s for optional |
| Accuracy | 0.5% -- 2.0% F.S. |
| Cable Length | Std: 10m |
| Communication | 4-20mA, Relay and OCT output |
| Degree of protection | IP66 according to EN60529 |
| Display | 2 line × 8 characters LCD, 8-digit rate or 8-digit total (resettable) |
| Enclosure Type | Wall-mounted |
| Flow velocity range | 0.05- 12 m/s |
| Housing Material | Fiberglass |
| Keypad | 4 pcs buttons |
| Liquid Types Supported | Liquids containing 100ppm of reflectors and at least 20% of the reflectors are larger than 100 micron. |
| Material of transducer | Aluminum for standard temp.sensor and peek for high temp.sensor |
| Measurement Principle | Doppler ultrasonic |
| Next | wetted type stainless steel insertion ultrasonic flow meter wall mounting |
| Operating Temperature | -20℃ to +60℃ |
| Pipe diameter range | 40- 4 000 mm |
| Power supply | AC: 85-265V DC: 24V/500mA |
| Previous | Doppler Pipeline Ultrasonic Flow Meter for insdutrial wastewater |
| Rate | Rate and Velocity Display |
| Repeatability | 0.2% of reading |
| Resolution | 0.25mm/s |
| Size | 244(h)*196(w)*1 1 4(d)mm |
| Suited Liquid Temperature | Std. Temp.: -35℃~85℃ for short periods up to 120℃ |
| Totalized | gallons, ft³, barrels, lbs, liters, m³,kg |
| Transducer Size | 60(h)*34(w)*3 2 (d)mm |
| Transducers Type | Clamp-on |
| Units | User Configured (English and Metric) |
| Weight | 2.4kg |
Points to check before using DN750MM in a design. They are derived from the recorded characteristics, not from the manufacturer's application circuits.
| Power supply | AC: 85-265V DC: 24V/500mA |
Check the exact pin assignment and the application circuit in the datasheet, or ask our experts.
Answers to the questions that the recorded characteristics of DN750MM can answer. A question is not asked when nothing is recorded to answer it.
-20℃ to +60℃ (source: Operating Temperature).
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
Doppler ultrasonic flow meter, clamp-on

Insertion Doppler Ultrasonic Flowmeter

Handheld Doppler Ultrasonic Flowmeter

Portable Doppler Ultrasonic Flowmeter

Describe your application and constraints in a request.
What is recorded about the regulatory status and the life of this part.
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
| Current status | Status not stated |
| Key dates | Not recorded |
| Manufacturer part number | DN750MM |
| Manufacturer | Lanry |
Ultrasonic Flow Meters
Portable ultrasonic flow meter with clamp-on transducers
Price on request
Ultrasonic Flow Meters
Non-contact ultrasonic flow meter for industrial pipelines
Price on request
Ultrasonic Flow Meters
Portable dual-channel transit-time ultrasonic flow meter · Ref. : ORIGINAL-FACTORY-PORTABLE-ULTRASONIC-FLOW-METER-DUAL-CHANNEL-TRANSIT-TIME-CLAMP
Price on request
Ultrasonic Flow Meters
High-temperature ultrasonic flow transducer · Ref. : US0081
Price on request
No advertising or analytics cookies. A single, strictly necessary cookie is set only if you sign in to your account. Your quote basket and comparison stay in your browser. Details