PORTABLE-ULTRASONIC-SENSOR-LIQUID-FLOW-METER
Portable ultrasonic transit-time liquid flow meter

- Operating Temperature
- -20℃ to +60℃
- Flow velocity range
- 0.01 to 12 m/s, bi-directional
- Response time
- 0.5s
- Cable Length
- Std: 5m
Portable ultrasonic transit-time liquid flow meter
Portable ultrasonic flow meter with non-intrusive clamp-on transducers for measuring liquid flow in fully filled pipes. Suited to maintenance, control and calibration tasks.
Overview. The TF1100-CH portable ultrasonic flow meter from Lanry works on the transit-time principle, with transducers clamped on the external surface of the pipe. Measurement is non-invasive and requires no cutting of the pipeline.
Main characteristics. Flow velocity range of 0.01 to 12 m/s, bi-directional. Accuracy of ±1.0% of reading at rates above 0.3 m/s and ±0.003 m/s of reading below 0.3 m/s. Repeatability of 0.2% of reading, resolution of 0.25 mm/s and response time of 0.5 s. Backlit graphic LCD display of 4 lines by 16 characters, user-selectable damping from 0 to 99 s, units user-configured in English and Metric.
Pipe sizes and liquids. Pipe diameter ranges of 20 to 50 mm (type S), 40 to 1000 mm (type M) and 1000 to 6000 mm (type L). Works with clean and somewhat dirty liquids with turbidity below 10000 ppm. Suited liquid temperature of -35 °C to 85 °C, up to 120 °C for short periods.
Functions and connectivity. Data logging, totalization in gallons, ft³, barrels, lbs, liters, m³ and kg, with OCT and RS-232 communication. Keypad and system lockout for operational security.
Power and environment. AC power supply 85 to 265 V and rechargeable internal batteries providing up to 14 h of operation. IP65 degree of protection according to EN60529, operating temperature of -20 °C to +60 °C, ABS housing (UL 94HB) measuring 212 × 100 × 36 mm for 0.5 kg.
Typical uses. Checking installed flow meters, flow rate calibration, data comparison and verification of meter running status, supporting service and maintenance activities.
No published question about this part yet. Questions are reviewed before publication.
Every characteristic recorded for PORTABLE-ULTRASONIC-SENSOR-LIQUID-FLOW-METER, with where it comes from. Use the filters to find one quickly.
| Characteristic | Value |
|---|---|
| Response time | 0.5s |
| Accuracy | ±1.0% of reading at rates >0.3 m/s); ±0.003 m/s of reading at rates<0.3 m/s |
| Cable Length | Std: 5m |
| Communication | OCT, RS232,Logged data |
| Damping of displayed value | 0-99s(selectable by user) |
| Degree of protection | IP65 according to EN60529 |
| Display | 4 line×16 English letters LCD graphic display, backlit |
| Enclosure Type | Handheld |
| Flow velocity range | 0.01 to 12 m/s, bi-directional |
| Housing Material | ABS( UL 94HB) |
| Liquid Types Supported | both clean and somewhat dirty liquids with turbidity <10000 ppm |
| Material of transducer | Aluminum for standard temp. s ensor, and peek for high temp. sensor |
| Measurement Principle | Ultrasonic transit-time difference correlation principle |
| Operating Temperature | -20℃ to +60℃ |
| Pipe diameter range | 20-50mm for type S, 40-1000mm for type M, 1000-6000mm for type L |
| Power supply | AC: 85-265V Up to 14 h with fully charged internal batteries |
| Rate | Rate and Velocity Display |
| Repeatability | 0.2% of reading |
| Resolution | 0.25mm/s |
| Security | Keypad lockout, system lockout |
| Sensitivity | 0.003m/s |
| Size | 212*100*36mm |
| Suited Liquid Temperature | Std. Temp.: -35℃~85℃ for short periods up to 120℃ |
| Totalized | gallons, ft³, barrels, lbs, liters, m³,kg |
| Transducer Size | Type S 48 (h)*28(w)*2 8 (d)mm |
| Units | User Configured (English and Metric) |
| Weight | 0.5kg |
No specification matches.
Last verification : 2026-11-03
Points to check before using PORTABLE-ULTRASONIC-SENSOR-LIQUID-FLOW-METER in a design. They are derived from the recorded characteristics, not from the manufacturer's application circuits.
| Power supply | AC: 85-265V Up to 14 h with fully charged internal batteries |
Check the exact pin assignment and the application circuit in the datasheet, or ask our experts.
Answers to the questions that the recorded characteristics of PORTABLE-ULTRASONIC-SENSOR-LIQUID-FLOW-METER can answer. A question is not asked when nothing is recorded to answer it.
Yes — recorded under "Communication": OCT, RS232,Logged data.
-20℃ to +60℃ (source: Operating Temperature).
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
Portable ultrasonic transit-time liquid flow meter

Analog 4~20mA Flowmeter Digital RS485 Clamp on Ultrasonic Water Liquid Flow Meter Sensor

Hydraulic digital ultrasonic water sensor liquid flow meter

Rs485 Ultrasonic Module Flow Sensor Heat Sensor Ultrasonic Fow Meter

Describe your application and constraints in a request.
What is recorded about the regulatory status and the life of this part.
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
| Current status | Status not stated |
| Key dates | Not recorded |
| Manufacturer part number | PORTABLE-ULTRASONIC-SENSOR-LIQUID-FLOW-METER |
| Manufacturer | Lanry |
Ultrasonic Sensors
Ultrasonic distance sensor module for WisBlock · Ref. : 100042
Price on request
Ultrasonic Sensors
IP67 waterproof transceiver ultrasonic distance sensor · Ref. : DYP-A06
Price on request
Ultrasonic Sensors
Ultrasonic distance sensor 300 to 5000 mm, multiple outputs · Ref. : SEN0269
Price on request
Ultrasonic Sensors
HC-SR04 Ultrasonic Distance Sensor for Arduino · Ref. : EL-SM-003
Price on request
With your consent, we use Google cookies to measure the site’s audience and our advertising. Your quote basket and comparison stay in your browser either way. Details