Lifud RDP202-01 main control board for mode 2 EV chargers, with adjustable output up to 16 A and 3.6 kW max. Meets EU and China GB standards.
Temperature range at; storage-40 ℃~ +85 ℃
Man-machine interaction — Screen/indicator light/key interfaceUsed with RDC201-02
O utput current — 16A max.6A-16A adjustable
Overcurrent> current value set +2A
Stand-by power; consumption — < 5WPower in non-charging state
Your current locationHome page
Product overview
Lifud RDP202-01 mode 2 EV charger control board — The RDP202-01 main control board from manufacturer Lifud is designed to manage a mode 2 electric vehicle charging station, in accordance with GB and IEC mode 2 standards.
Main characteristics. Adjustable output current from 6 A to 16 A, output power 3.6 kW max., output voltage equal to the input voltage of 100 to 240 Vac. The charging logic can be adjusted by software, with Plug & charge function.
Protections. Overcurrent protection (triggered above the set current +2 A), overvoltage protection (alarm and immediate relay disconnection if 270 Vac is maintained for 2 seconds), undervoltage protection (alarm and disconnection if 100 Vac is maintained for 2 seconds), plug over-temperature protection (output turned off when the NTC exceeds 70 °C), ground protection, and surge protection rated ±2000 V L-N and ±4000 V L/N-PE. Type A+DC6mA residual current detection.
Interfaces and communication. Serial digital interface, mainly used for external WIFI or Bluetooth modules, with a reserved input plug over-temperature protection interface. The human-machine interface (screen, indicator lights and keys) is used together with the RDC201-02 module.
Power and environment. Standby consumption below 5 W. Operating temperature -30 °C to +50 °C, storage temperature -40 °C to +85 °C, humidity 5% to 95% without condensation, operating altitude below 3000 m. Input frequency 50/60 Hz. Dimensions 144 x 60 x 29.5 mm, weight 135 g.
Certifications and safety. CE and TUV certified for the complete system. Insulating strength 2U+1200 V for 60 s, insulation resistance above 5 MΩ at 500 Vdc.
Integration. Board intended to be integrated into a mode 2 EV charger whose electrical characteristics must match those of the board. Available on quotation from Atlas Electronics.
No published question about this part yet. Questions are reviewed before publication.
Complete specifications
Every characteristic recorded for RDP202-01, with where it comes from. Use the filters to find one quickly.
All specifications (29)
Characteristic
Value
Ambient temperature; range — -30 ℃~ +50 ℃
Ultimate temperature for the test of the matching housing (relay Tc<110 ℃ )
Certification — CE — TUV
Complete system testing
Charger-enable — Plug & charge
The charging logic can be adjusted via software
Communication mode — Serial digital interface
Mainly used for external WIFI/Bluetooth modules
Emergency plug; disconnection
Return to standby mode after emergency; disconnection
Ground — With ground protection function
The screen displays the corresponding fault, and the emergency charging state is entered through manual control. Re-powering on can restore the error report
Humidity during operation
5%-95%, no condensation
Input Frequency
50/60Hz
Input voltage — 100-240Vac
Limit 90-264V; Protection is implemented beyond this range
If 270Vac is maintained for 2 seconds, an alarm will be triggered and the relay will be disconnected immediately. Normal operation is restored until the voltage is identified to be less than 260Vac for 2 consecutive seconds
Plug over-temperature — NTC temp. >70 ℃
Turn off the output
Product Weight
135g
Relay welding
The screen displays the corresponding fault
Size
144*60*29.5mm
Stand-by power; consumption — < 5W
Power in non-charging state
Surge
L-N: ± 2000V L/N-PE: ± 4000V
Temperature range at; storage
-40 ℃~ +85 ℃
Undervoltage — Input voltage ≤ 100Vac
If 100Vac is maintained for 2 seconds, an alarm will be triggered and the relay will be disconnected immediately. Normal operation is restored until the voltage is identified to be greater than 110Vac for 2 consecutive seconds
Your current location
Home page
No specification matches.
Last verification : 2026-11-02
Technical documentation
Official documents and the technical data recorded for RDP202-01. For a missing document or a specific revision, our experts send it to you.
Lifud RDP202-01 main control board for mode 2 EV chargers, with adjustable output up to 16 A and 3.6 kW max. Meets EU and China GB standards.
Temperature range at; storage-40 ℃~ +85 ℃
Man-machine interaction — Screen/indicator light/key interfaceUsed with RDC201-02
O utput current — 16A max.6A-16A adjustable
Overcurrent> current value set +2A
Stand-by power; consumption — < 5WPower in non-charging state
2. Datasheet extract (recorded values)
Parameter
Value
Ambient temperature; range — -30 ℃~ +50 ℃
Ultimate temperature for the test of the matching housing (relay Tc<110 ℃ )
Certification — CE — TUV
Complete system testing
Charger-enable — Plug & charge
The charging logic can be adjusted via software
Communication mode — Serial digital interface
Mainly used for external WIFI/Bluetooth modules
Emergency plug; disconnection
Return to standby mode after emergency; disconnection
Ground — With ground protection function
The screen displays the corresponding fault, and the emergency charging state is entered through manual control. Re-powering on can restore the error report
Humidity during operation
5%-95%, no condensation
Input Frequency
50/60Hz
Input voltage — 100-240Vac
Limit 90-264V; Protection is implemented beyond this range
If 270Vac is maintained for 2 seconds, an alarm will be triggered and the relay will be disconnected immediately. Normal operation is restored until the voltage is identified to be less than 260Vac for 2 consecutive seconds
Plug over-temperature — NTC temp. >70 ℃
Turn off the output
Product Weight
135g
Relay welding
The screen displays the corresponding fault
Size
144*60*29.5mm
Stand-by power; consumption — < 5W
Power in non-charging state
Surge
L-N: ± 2000V L/N-PE: ± 4000V
Temperature range at; storage
-40 ℃~ +85 ℃
Undervoltage — Input voltage ≤ 100Vac
If 100Vac is maintained for 2 seconds, an alarm will be triggered and the relay will be disconnected immediately. Normal operation is restored until the voltage is identified to be greater than 110Vac for 2 consecutive seconds
Your current location
Home page
Applications and use cases
Architectures in which RDP202-01 can play a role, derived from its category. This is not a compatibility statement: check the specifications against your requirements.
Solar production, storage and charging points on one site are often managed separately. Inverters, batteries, MPPT controllers, meters and chargers form a local energy system that shares production between users
To check
Regulatory framework for collective self-consumption in the country
Energy management system steering storage and charging
Metering accuracy for sharing between participants
Associated system blocks
ProductionStorageMeteringCharging
Need a complete solution?
Send a request for RDP202-01 and the other parts of your project.
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
No advertising or analytics cookies. A single, strictly necessary cookie is set only if you sign in to your account. Your quote basket and comparison stay in your browser. Details