Three-phase DIN rail energy meter for measuring grid parameters in photovoltaic and energy storage installations, with RS485 Modbus-RTU output.
Product overview
Overview. The Livoltek LHE34C three-phase energy meter is a multifunction DIN rail meter with external current transformers. It measures active and reactive energy, voltage, current, power, power factor and frequency.
Main characteristics. Accuracy class 1 for active energy and class 2 for reactive energy. Open-type current transformers 120A/48mA and 250A/50mA, supporting two three-phase loops. Dimensions 101 mm x 72 mm x 67 mm.
Interfaces and connectivity. RS485 communication port with Modbus-RTU protocol, configurable baud rates from 1200 to 115200. Quick-plug terminals for RS485 and RJ45 external CT port. Instantaneous refresh of 100 ms for voltage, current, active power, reactive power and power factor. The 12 V 2.5 W power supply allows expansion with Bluetooth or Wi-Fi communication modules.
Power and environment. Nominal voltage 3×120/210 V, 3×230/400 V or 3×240/415 V, operating range 70% to 130% of Un. Frequency 50 Hz or 60 Hz.
Typical uses. Monitoring of production and consumption in photovoltaic installations and energy storage power stations. Real-time data sent over RS485 lets inverters and other devices adapt their response.
Integration. Standard DIN rail mounting. Available on quotation from Atlas Electronics.
Open-type CT: 120A/48mA; 250A/50mA Supports two three-phase loops
Dimension (HxWxD)
101mmx72mmx67mm
Frequency
50Hz/60Hz
Voltage
Nominal Voltage: 3×120/210V, 3×230/400V, 3×240/415V Operating Voltage Range: 70%Un~130%Un
Applications and use cases
Architectures in which LHE34C can play a role, derived from its category. This is not a compatibility statement: check the specifications against your requirements.
Energy bills give one total for the whole site. Submetering places meters and current sensors on each circuit or usage and collects their readings through a gateway, so consumption can be followed per building, floor or machine
To check
Number of circuits and phases to meter, and the current range of each
Wired Modbus bus or wireless LoRaWAN, depending on cabling access in the switchboards
Accuracy class required for internal allocation or for billing
A building’s energy, comfort and occupancy data sit in separate systems. Sensors, meters and gateways feed one model of the building, room by room, to compare scenarios and steer the installations
To check
Data model and building plans available
Software platform hosting the twin
Sensor density needed for a useful model
Associated system blocks
SensorsMetersGateways
Need a complete solution?
Send a request for LHE34C and the other parts of your project.
Answers to the questions that the recorded characteristics of LHE34C can answer. A question is not asked when nothing is recorded to answer it.
1Does it support RS-485?
Yes — recorded under "Communication port": RS485 communication port, Modbus-RTU Protocol Baud rate:1200、2400、4800、9600、19200、38400、115200(configurable).
2Does it support Modbus?
Yes — recorded under "Communication port": RS485 communication port, Modbus-RTU Protocol Baud rate:1200、2400、4800、9600、19200、38400、115200(configurable).
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
Current productLivoltek
LHE34C
Three-phase energy meter 3P4W/3P3W with external current transformers
What is recorded about the regulatory status and the life of this part.
Regulatory compliance
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
With your consent, we use Google cookies to measure the site’s audience and our advertising. Your quote basket and comparison stay in your browser either way. Details