| Dimensions | Main Body: 112mm (L) x 88.19mm (W) x 32mm (H) |
| Antenna Type | Built-in antenna |
| Available Frequency | EU863-870, US902-928, AU915-928, KR920-923, AS923-1, AS923-2, AS923-3, IN865-867, CN470-510 Note: Optional, configured before shipment |
| Available LoRaWAN Band | EU863-870, US902-928, AU915-928, KR920-923, AS923-1, AS923-2, AS923-3,; IN865-867, CN470-510; (Note: optional, to be configured before shipment) |
| Battery Life | 4.8 years (conditions: ambient temperature 25 °C, 15 min report once, txpower = 20dBm, LoRa spreading factor SF = 10) |
| Battery Lifespan | 4.8 years; (when the temperature = 25℃, report once every 15 minutes,; TX power = 20dBm, and LoRa spreading factor SF = 10) |
| Battery Measurement Accuracy | ±0.1V |
| Communication Distance | 10 km (line of sight); (Note: The actual transmission distance depends on the environment.) |
| Communication Range | 10km (line of sight) Note: The actual transmission distance depends on the environment. |
| Data Transfer Rate | LoRa: 0.3kbps – 50kbps; FSK: 1.2kbps – 300kbps |
| Environment Humidity Range | <90%RH (No condensation) |
| Environment Temperature Range | -20°C – 55 °C |
| Frequency Range | 863MHz-928MHz 470MHz-510MHz |
| Input power | 2 x 3.6V ER14505 AA size lithium batteries (3.6V2400mah/section) |
| Low Battery Voltage Threshold | 3.2V |
| Measurement Accuracy | ±1.5℃ (0℃ ≤ T ≤ 600℃); 2 ±0.0025 * T ℃ (600℃ < T ≤ 1400℃) 2 2 Note: (1) Temperature range of the main body: 0℃ ≤ T ≤ 55℃. 1 (2) T : the temperature of the main body; T : temperature of the thermocouple 1 2 |
| Measurement Range | 0℃ ≤ t ≤ 1400℃ |
| Modulation | LoRa/FSK (Note: One modulation method is required.) |
| Modulation Method | LoRa/FSK Note: One modulation method is required. |
| Operating Voltage | 3.1V – 3.65V |
| Probe length | 500mm (customizable) |
| RF Receiving Current (max) | 11mA/3.3V |
| RF Transmitting Current (max) | 120mA/3.3V |
| RX Sensitivity | -136dBm(LoRa, Spreading Factor=12,Bit Rate=293bps); -121dBm (FSK, Frequency deviation=5kHz, Bit Rate=1.2kbps) |
| Standby Current | 34uA |
| Storage Temperature | -40℃–85℃ |
| Storage Temperature Range | -40℃–85℃ |
| Thermocouple Measurement Accuracy | ±1.5℃ (0℃ ≤ T2 ≤ 600℃); ±0.0025 * T2℃ (600℃ < T2 ≤ 1400℃) |
| Thermocouple Measurement Range | 0℃ ≤ t ≤ 1400℃ |
| Tx Power | US915 20dbm; AS923 16dbm; AU915 20dbm; CN470 19.15dbm; EU868 16dbm; KR920 14dbm; IN865 20dbm |
| Wake-up Current | 7.33mA (typical value); 0.8mA–20 mA (without transmitting /receiving LoRa data) |
| Wakeup Current | 7.33mA (typical value); 0.8mA–20 mA (without transmitting /receiving LoRa data) |
| Wire length | 2m |
| Wire Material | Platinum rhodium |