Netvox R718N1100DE single-phase wireless current meter with a detachable 1000A clamp-on current transformer, measuring alternating current on a conductor and transmitting data over LoRaWAN.
Ambient temperature range-20°C to +55 °C
Clamp-On CT Operating Temperature-20 ℃ to +50 ℃
Operating Temperature-20 ℃ to +50 ℃
Storage Temperature Range-40°C to +85°C
Ambient Humidity Range<90%RH (No condensation)
Current Measurement Range10A – 1000A
Product overview
Overview. The Netvox R718N1100DE is a single-phase current meter that measures alternating current up to 1000A. The clamp-on current transformer is fitted around a conductor, measurement is made without direct contact, and data is sent to the gateway through an integrated LoRaWAN module.
Main characteristics. Measurement range from 10A to 1000A, accuracy of 0.5%, resolution of 1mA and saturation current of 1000A. The transformer ratio is 2000:1 with a rated secondary current of 500mA.
Interfaces and connectivity. SX1276 LoRaWAN-compatible module with built-in antenna and a communication range of 10 km line of sight. LoRa or FSK modulation, receiving sensitivity of -136dBm in LoRa, available bands EU863-870, US902-928, AU915-928, KR920-923, AS923, IN865-867 and CN470-510, to be configured before shipment. Third-party platforms Actility/ThingPark, TTN and MyDevices/Cayenne are supported.
Power and environment. DC 3.3V/1A power supply, power consumption of 0.5W or less. Main body rated IP53, sensor IP30. Operating temperature from -20 °C to +50 °C, ambient humidity below 90% RH without condensation, flame-retardant UL 94-V0 case material. RoHS compliant, CE and UL certified.
Mounting. Screw or magnet mounting, detachable sensor cable of about 1200mm, main body weight of about 141g. Main body dimensions 112 mm x 88.19 mm x 32 mm.
Netvox R718N1100DE single-phase wireless current meter with a detachable 1000A clamp-on current transformer, measuring alternating current on a conductor and transmitting data over LoRaWAN.
Ambient temperature range-20°C to +55 °C
Clamp-On CT Operating Temperature-20 ℃ to +50 ℃
Operating Temperature-20 ℃ to +50 ℃
Storage Temperature Range-40°C to +85°C
Ambient Humidity Range<90%RH (No condensation)
2. Datasheet extract (recorded values)
Parameter
Value
Dimensions
Main body:112mm (L) x 88.19mm (W) x 32mm (H); Sensor: 119mm x 97mm x 59.5mm
Accuracy
0.5%
Ambient Humidity Range
<90%RH (No condensation)
Ambient temperature range
-20°C to +55 °C
Antenna Type
Built-in antenna
Available LoRaWAN Band
EU863-870, US902-928, AU915-928, KR920-923, AS923-1, AS923-2, AS923-3,; IN865-867, CN470-510; (Note: optional, to be configured before shipment)
Case Material
Flame Retardant Grade 94-V0 UL Material
Clamp-On CT Accuracy
0.5%
Clamp-On CT Case Material
Flame Retardant Grade 94-V0 UL Material
Clamp-On CT Electrical Strength
2000V/0.3mA/3S
Clamp-On CT Environmentally Friendly
ROHS compliant, CE/UL certified
Clamp-On CT Load Resistance
0.36Ω
Clamp-On CT Operating Temperature
-20 ℃ to +50 ℃
Clamp-On CT Rated Primary Current
1000A, 50Hz – 60Hz
Clamp-On CT Rated Secondary Current
500mA
Clamp-On CT Ratio
2000: 1
Clamp-On CT Saturation Current
1000A
Communication Distance
10 km (line of sight)
Communication Range
10km (line of sight) Note: The actual communication range may vary due to the environment.
Current Measurement Accuracy
<±1%
Current Measurement Range
10A – 1000A
Current Resolution
1mA
Data Transfer Rate
LoRa: 0.3kbps – 50kbps; FSK: 1.2kbps – 300kbps
Dimension
Main body: 112mm (L) x 88.19mm (W) x 32mm (H) Sensor: 119mm x 97mm x 59.5mm
Electrical Strength
2000V/0.3mA/3S
Environmentally Friendly
ROHS compliant, CE/UL certified
Frequency Range
863MHz-928MHz 470MHz-510MHz
Load Resistance
0.36Ω
Main body Weight
About 141g
Modulation
LoRa/FSK (Note: One modulation method is required.)
Mounting
Screw / Magnet
Mounting Method
Screw / Magnet
Operating Temperature
-20 ℃ to +50 ℃
Power consumption
≤ 0.5W
Power supply
DC 3.3V/1A
Rated Primary Current
1000A, 50Hz – 60Hz
Rated Secondary Current
500mA
Ratio
2000: 1
Receiving Sensitivity
-136dBm(LoRa, Spreading Factor=12,Bit Rate=293bps );; -121dBm (FSK, Frequency deviation=5kHz, Bit Rate=1.2kbps)
RF emission current
127 mA / 3.3 V
RF Receiving Current
11 mA / 3.3V
RX Sensitivity
-136dBm (LoRa, Spreading Factor = 12, Bit Rate = 293bps) -121dBm (FSK, Frequency deviation = 5kHz, Bit Rate = 1.2kbps)
Points to check before using R718N1100DE in a design. They are derived from the recorded characteristics, not from the manufacturer's application circuits.
1Thermalrated operating range -20 ℃ to +50 ℃ — check it against the installation environment.
2Thermalrated operating range -20 ℃ to +50 ℃ — check it against the installation environment.
Check the exact pin assignment and the application circuit in the datasheet, or ask our experts.
Implementation checklist
Thermal : rated operating range -20 ℃ to +50 ℃ — check it against the installation environment.
Thermal : rated operating range -20 ℃ to +50 ℃ — check it against the installation environment.
Applications and use cases
Architectures in which R718N1100DE can play a role, derived from its category. This is not a compatibility statement: check the specifications against your requirements.
Diseases and water stress are noticed once the crop is already affected. A weather station, soil probes and sensor nodes in the field report conditions through an outdoor gateway
To check
Crops, plots and measurement depth of the soil probes
A LoRaWAN project needs sensors, gateways, a network server and an application that work together. Sensor nodes report to indoor or outdoor gateways, which forward the data to the network server and the customer’s platform
To check
Regional frequency plan (EU868, US915 and others)
Network server: public, private or embedded in the gateway
Milesight sensors, LoRaWAN gateways and cellular routers can be brought together on the Milesight Development Platform, which manages the devices and passes their data to other applications through an API and webhooks
To check
Development Platform for device management, API and webhooks, or another network server and application
Devices provisioned through Milesight RPS must have that provisioning removed before being added to the Development Platform
Data flows to the customer’s own application through webhooks
RAKwireless WisGate gateways run WisGateOS 2 and are managed from WisDM, RAKwireless’ cloud device management platform with a built-in network server, alongside RAK sensor nodes, radio modules and concentrators
To check
WisDM built-in network server, or a third-party one (ChirpStack, TTN/TTS, AWS IoT Core, Actility)
Remote configuration and updates of the gateways from WisDM
Regional frequency plan of the gateways and nodes
Associated system blocks
GatewaysSensors and modulesDevelopment boardsMounting
Seeed SenseCAP sensors connect to Seeed’s SenseCAP cloud platform and app, and Seeed edge computers, camera modules, Grove and XIAO boards complete the chain for custom devices and local processing
To check
SenseCAP cloud platform and app, or the customer’s own network server
Prototype on Grove and XIAO, then move to industrial versions
Local processing on the edge computers or in the cloud
Associated system blocks
SensorsEdge computingDevelopment boards
Need a complete solution?
Send a request for R718N1100DE and the other parts of your project.
Answers to the questions that the recorded characteristics of R718N1100DE can answer. A question is not asked when nothing is recorded to answer it.
1Does it support LoRaWAN?
Yes — recorded under "Available LoRaWAN Band": EU863-870, US902-928, AU915-928, KR920-923, AS923-1, AS923-2, AS923-3,; IN865-867, CN470-510; (Note: optional, to be configured before shipment).
2What is the operating temperature range?
-20 ℃ to +50 ℃ (source: Clamp-On CT Operating Temperature).
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
Current productNetvox
R718N1100DE
Single-Phase Wireless Current Meter with 1000A Clamp
What is recorded about the regulatory status and the life of this part.
Regulatory compliance
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
With your consent, we use Google cookies to measure the site’s audience and our advertising. Your quote basket and comparison stay in your browser either way. Details