R900A03AO1 – Wireless water leak detector with rope sensor

Wireless water leak detector with rope sensor

Environmental Sensor Nodes

  • -20℃ to +55℃
  • -20°C ~ 55°C
  • 75°C
  • 12mA @3.3V
Manufacturer part number
R900A03AO1
Manufacturer
Netvox
Operating Temperature
-20°C ~ 55°C
Max operating temperature
75°C

Netvox R900A03AO1 wireless water leak detector with a 3000 mm rope sensor and a 3.3 V digital output, for LoRaWAN-based leak detection.

Product overview

Overview. The Netvox R900A03AO1 is a wireless water leak detector from Netvox, fitted with a 3000 mm orange rope sensor and a 3.3 V digital output. It signals the presence of water along the cable and sends the alarm by radio.

Main characteristics. The rope sensor, made of conductive polyethylene and alloy wire, measures 5.5 mm in diameter and has a breaking strength of 60 kg. The recommended maximum length is 300 meters (theoretical value). The host body measures 115.5 mm x 60 mm x 54 mm.

Interfaces and connectivity. The device communicates over LoRaWAN® (Class A) with LoRa or FSK modulation, on the EU863-870, US902-928, AU915-928, KR920-923, AS923-1, AS923-2, AS923-3, IN865-867 and CN470-510 bands, configured before shipment. Range reaches 10 km in line of sight and depends on the environment.

Power and environment. It runs on 2 x ER18505 3.6 V 4000 mAh lithium batteries, with a battery lifespan of 5.69 years under the manufacturer's reference conditions. It operates between -20 °C and +55 °C, with humidity below 90 %RH without condensation.

Installation. Mounting by screws, double-sided tape or standard bracket, with optional DIN rail, magnetic or swivel bracket.

See all specifications

Highlights

  • Dimensions: L: 115.57mm x W:60mm x H: 54.19mm
  • Ambient Humidity: <90%RH (no condensation)
  • Ambient Operating Temperature: -20℃ to +55℃
  • Ambient Storage Temperature: -40℃ to +85℃
  • Antenna Type: Built-in antenna
  • Battery Low Voltage Alarm: 3.3V

Typical applications

Derived from the part category, not a compatibility statement.

Good to know before integrating

  • Thermal: rated operating range -20℃ to +55℃ — check it against the installation environment.
  • Thermal: rated operating range -20°C ~ 55°C — check it against the installation environment.
  • Thermal: rated operating range 75°C — check it against the installation environment.