| Air Temperature — -40 to 80°C — ±0.5°C | 0.1°C |
| Average power consumption | Approx. 1 W with particulate matter sensor |
| Barometric Pressure — 10–1100 hPa — ±1.5 hPa | 0.1 hPa |
| Barometric Pressure — Atmospheric pressure | Meteorological and aviation monitoring |
| Baud rate | 9600 bps |
| Cable | Use suitable outdoor cable protection and strain relief. |
| Communication Item | Specification |
| Complete Remote Monitoring Station | Add a compatible data logger, communication gateway, power system and mounting structure |
| Device Address Range | 0–255 |
| Humidity — Atmospheric relative humidity | Agriculture and environmental monitoring |
| Illuminance | Unit: Lux; Typical Application: Visible light and ambient lighting monitoring |
| Illuminance — 0–200,000 Lux — ±7% | 10 Lux |
| Installation Item | Recommendation |
| Interface | RS485 |
| IP65 Protection | Designed for outdoor environmental monitoring |
| Measured Parameters | Wind Speed, Wind Direction, Temperature, Humidity, Pressure, Rainfall, PM2.5, PM10 + Solar Radiation or Illuminance |
| Minimum Communication Interval | 1000 ms |
| Mounting | Install the sensor securely on a stable vertical mounting pipe. |
| Noise | Yes |
| Noise Required | Select a configuration that specifically includes environmental noise measurement |
| North Alignment | Align the sensor's north reference point with geographic north. |
| Operating Humidity | 0–95% RH |
| Operating Temperature | -40 to 80°C |
| PAR / PPFD | Unit: µmol/m²/s; Typical Application: Requires a dedicated PAR sensor |
| PAR / PPFD Required | Add a dedicated PAR sensor |
| Parity | None |
| Piezoelectric Rainfall | Integrated rainfall measurement without a mechanical tipping mechanism |
| PM10 — 0–2000 µg/m³ — ±10% | 1 µg/m³ |
| PM10 — 0–2000 µg/m³ — 1 µg/m³ | Dust and ambient particulate monitoring |
| PM10 — Coarse inhalable particulate matter | Dust and environmental monitoring |
| PM2.5 — 0–1000 µg/m³ — ±10% | 1 µg/m³ |
| PM2.5 — 0–1000 µg/m³ — 1 µg/m³ | Fine particulate monitoring |
| PM2.5 — Fine airborne particulate matter | Ambient air-quality monitoring |
| PM2.5 + PM10 | Adds particulate matter monitoring to meteorological measurements |
| PM Monitoring | Allow representative ambient air to reach the particulate sensing section without obstruction. |
| Power supply | DC 9–24V or DC 12–24V |
| Product Type | 9-in-1 Ultrasonic Weather & Environmental Sensor |
| Products | Weather Stations |
| Project Requirement | Recommended Selection |
| Protection rating | IP65 |
| Protocol | Modbus RTU |
| Radar / Radio Equipment | Avoid the same plane as radar scanning equipment and maintain suitable separation from strong radio sources. |
| Rainfall | No in standard 81GUWS configuration |
| Rainfall — 0–8 mm/min — ±10% | 0.01 mm |
| Rainfall Exposure | Keep the rainfall sensing surface unobstructed and directly exposed to precipitation. |
| Rainfall Measurement | Piezoelectric Raindrop Impact Detection |
| Rainfall — Piezoelectric rainfall measurement | Weather, agriculture and hydrometeorological monitoring |
| Regulatory PM Monitoring Required | Confirm required reference method, calibration and certification before selection |
| Relative Humidity — 0–100% RH — ±5% RH | 0.1% RH |
| RS485 Modbus RTU | Digital integration with compatible PLCs, data loggers and IoT gateways |
| Signal Output | RS485 |
| Solar / Light Exposure | Avoid unintended shading when solar radiation or representative illuminance measurement is required. |
| Solar Radiation | Unit: W/m²; Typical Application: Meteorology, solar energy, evapotranspiration and agricultural monitoring |
| Solar Radiation* — 0–1500 W/m² — ±10% | 1 W/m² |
| Solar Radiation / Illuminance | Select one according to the monitoring requirement |
| Solar Radiation / Illuminance — Solar irradiance in W/m² or visible light intensity in Lux | Agriculture, solar and environmental monitoring |
| Temperature — Ambient air temperature | Agriculture, weather and environmental monitoring |
| Typical Selection | Weather + PM + noise monitoring |
| Ultrasonic Wind Measurement | No conventional rotating wind cups or mechanical wind vane |
| Vibration | Avoid strong mechanical vibration sources. |
| Weather + Rainfall + PM2.5 + PM10 + Illuminance | NBL-W-91GUWS with Illuminance |
| Weather + Rainfall + PM2.5 + PM10 + Solar Radiation | NBL-W-91GUWS with Solar Radiation |
| wind direction — 0-359° — ±3° | 1° |
| Wind Direction — Direction from which the wind is blowing | Meteorology and pollutant dispersion monitoring |
| Wind Exposure | Avoid nearby trees, poles, walls and buildings that may disturb airflow. |
| Wind Measurement Principle | Ultrasonic Transit-Time Measurement |
| Wind Speed — 0–60 m/s — ±0.3 m/s + 3% F.S. | 0.01 m/s |
| Wind Speed — Wind velocity up to 60 m/s | Weather stations, aviation, ports and transportation |
| Wind + Temperature + Humidity + Pressure | Yes |