Niubol NBL-S-TMC soil probe measuring soil temperature, volumetric moisture and electrical conductivity in one unit, with RS485 Modbus RTU output.
InterfaceRS485 Modbus RTU
Observed trendWhat to investigate
ProductsWeather Stations
Product overview
The Niubol NBL-S-TMC is a soil probe combining soil temperature, volumetric moisture and electrical conductivity (EC) in one RS485 Modbus RTU sensor. Main characteristics — The sensor measures volumetric soil moisture from 0 to 100% with 0.1% resolution and a specified accuracy of 5%, soil temperature from -40 to 80 °C with 0.1 °C resolution and ±0.5 °C accuracy, and soil EC from 0 to 10000 microSiemens/cm with 1 microSiemens/cm resolution and ±5% accuracy within this range. EC temperature compensation is built in, with a specified compensation range of 0 to 50 °C. Methods — Moisture is measured by FDR reflectometry and conductivity by AC bridge measurement. Connectivity and power — The output is RS485 Modbus RTU and the supply is 5 to 24 VDC or 12 to 24 VDC depending on the ordered configuration. Construction and environment — The electrodes are corrosion-resistant, the probe is sealed in black flame-retardant epoxy, its protection rating is IP68 and its operating environment ranges from -40 to 85 °C. Dimensions — The probe measures 45 x 15 x 135 mm, with a 50 mm electrode section and a 5 m standard cable. Typical uses — The RS485 Modbus interface allows connection to a PLC or data acquisition system to monitor soil moisture, temperature and conductivity in an irrigation project. Integration — For representative placement, consider installation depth, soil texture and distance to emitters, since measured conductivity depends on electrode contact and water continuity in the soil.
No published question about this part yet. Questions are reviewed before publication.
Complete specifications
Every characteristic recorded for SOIL-CONDUCTIVITY-SENSOR-EC, with where it comes from. Use the filters to find one quickly.
All specifications (16)
Characteristic
Value
Construction
Corrosion-resistant electrodes; black flame-retardant epoxy sealing
Dimensions and cable
45 x 15 x 135 mm; 50 mm electrode section; 5 m standard cable
Dry soil gives a low EC value
Check continuity of the soil-water path and probe contact. Do not conclude that low conductivity proves low salt content.
EC remains elevated at comparable moisture on later visits
Check repeated events, sensor position, temperature treatment and a suitable soil analysis when a management limit is involved.
EC Temperature Compensation
Built-in; specified compensation range 0-50 degrees C
Housing protection and environment
IP68; operating environment -40 to 85 degrees C
Interface
RS485 Modbus RTU
Methods
FDR moisture measurement; AC bridge conductivity measurement
Moisture and EC rise together after irrigation
Review wetting, irrigation-water chemistry and any applied nutrient solution before assigning the EC increase to salt accumulation.
Observed trend
What to investigate
One point differs from neighboring probes
Compare depth, texture, emitter distance and disturbed soil before assuming the probe requires a calibration offset.
Products
Weather Stations
Soil EC
0-10000 microSiemens/cm; 1 microSiemens/cm resolution; +/-5% accuracy within this range
Soil temperature
-40 to 80 degrees C; 0.1 degree C resolution; +/-0.5 degree C accuracy
Supply
5-24 VDC or 12-24 VDC depending on the ordered configuration
Volumetric soil moisture
0-100%; 0.1% resolution; specified accuracy 5%
No specification matches.
Last verification : 2026-11-02
Technical documentation
Official documents and the technical data recorded for SOIL-CONDUCTIVITY-SENSOR-EC. For a missing document or a specific revision, our experts send it to you.
Niubol NBL-S-TMC soil probe measuring soil temperature, volumetric moisture and electrical conductivity in one unit, with RS485 Modbus RTU output.
InterfaceRS485 Modbus RTU
Observed trendWhat to investigate
ProductsWeather Stations
2. Datasheet extract (recorded values)
Parameter
Value
Construction
Corrosion-resistant electrodes; black flame-retardant epoxy sealing
Dimensions and cable
45 x 15 x 135 mm; 50 mm electrode section; 5 m standard cable
Dry soil gives a low EC value
Check continuity of the soil-water path and probe contact. Do not conclude that low conductivity proves low salt content.
EC remains elevated at comparable moisture on later visits
Check repeated events, sensor position, temperature treatment and a suitable soil analysis when a management limit is involved.
EC Temperature Compensation
Built-in; specified compensation range 0-50 degrees C
Housing protection and environment
IP68; operating environment -40 to 85 degrees C
Interface
RS485 Modbus RTU
Methods
FDR moisture measurement; AC bridge conductivity measurement
Moisture and EC rise together after irrigation
Review wetting, irrigation-water chemistry and any applied nutrient solution before assigning the EC increase to salt accumulation.
Observed trend
What to investigate
One point differs from neighboring probes
Compare depth, texture, emitter distance and disturbed soil before assuming the probe requires a calibration offset.
Products
Weather Stations
Soil EC
0-10000 microSiemens/cm; 1 microSiemens/cm resolution; +/-5% accuracy within this range
Soil temperature
-40 to 80 degrees C; 0.1 degree C resolution; +/-0.5 degree C accuracy
Supply
5-24 VDC or 12-24 VDC depending on the ordered configuration
Volumetric soil moisture
0-100%; 0.1% resolution; specified accuracy 5%
Applications and use cases
Architectures in which SOIL-CONDUCTIVITY-SENSOR-EC can play a role, derived from its category. This is not a compatibility statement: check the specifications against your requirements.
Diseases and water stress are noticed once the crop is already affected. A weather station, soil probes and sensor nodes in the field report conditions through an outdoor gateway
To check
Crops, plots and measurement depth of the soil probes
Power of the field devices (battery, solar)
Gateway coverage over the farm
Associated system blocks
Weather stationSoil and field sensorsGateway
Need a complete solution?
Send a request for SOIL-CONDUCTIVITY-SENSOR-EC and the other parts of your project.
Answers to the questions that the recorded characteristics of SOIL-CONDUCTIVITY-SENSOR-EC can answer. A question is not asked when nothing is recorded to answer it.
1Does it support RS-485?
Yes — recorded under "Interface": RS485 Modbus RTU.
2Does it support Modbus?
Yes — recorded under "Interface": RS485 Modbus RTU.
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
Current productNiubol
SOIL-CONDUCTIVITY-SENSOR-EC
Soil Temperature, Moisture and EC Sensor with RS485 Interface
What is recorded about the regulatory status and the life of this part.
Regulatory compliance
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
No advertising or analytics cookies. A single, strictly necessary cookie is set only if you sign in to your account. Your quote basket and comparison stay in your browser. Details