15913103-00
Electromagnetic Heat Meter Flow Transmitter

- Flow-rate range
- 0.5-10m/s
- Accuracy
- ±0.5%R, ±1%R (below DN200)
- Ambient Humidity
- 5%~95%
- Ambient temperature
- Sensor; Integrated type
Electromagnetic Heat Meter Flow Transmitter
NYLD-CH electromagnetic heat meter from Nuoying, measuring the heat carried by a heat transfer fluid in heating or air conditioning systems.
Overview. The Nuoying NYLD-CH is an electromagnetic flow meter designed as a heat meter, measuring the heat released by a heat transfer fluid in a thermal transfer system.
Main characteristics. Flow measurement is performed by an electromagnetic sensor with an accuracy of ±0.5%R, ±1%R below DN200. The flow rate range is 0.5 to 10 m/s and the nominal diameter 15 to 800 mm. The standard nominal pressure is 1.0 MPa. The measuring pipe has no resistance parts and no pressure loss.
Interfaces and connectivity. The signal output is 4-20 mA. The unit supports MODBUS, HART, GPRS and PROFIBUS digital communication, and a password protection function prevents modification of the operating parameters. The large backlit LCD display, in Chinese, is readable in strong light and in darkness, and shows cumulative heat and flow, instantaneous heat and flow rates, and inlet and outlet water temperatures simultaneously.
Power and environment. Protection is IP68 for the separate type and IP65 as stated in the data. Permissible ambient humidity ranges from 5% to 95%. The standard housing is carbon steel, stainless steel on request. Grounding rings are stainless steel or molybdenum-containing stainless steel. The unit carries an explosion-proof certification.
Typical uses. Measurement of heat consumption in central heating, heating and air conditioning networks of residential, office and institutional buildings.
Integration. Temperature is measured with a PT1000 platinum resistance sensor. The meter applies an enthalpy-based thermal correction suited to variations in water temperature. The product is available on quotation from Atlas Electronics.
No published question about this part yet. Questions are reviewed before publication.
Every characteristic recorded for 15913103-00, with where it comes from. Use the filters to find one quickly.
| Characteristic | Value |
|---|---|
| Accuracy | ±0.5%R, ±1%R (below DN200) |
| Ambient Humidity | 5%~95% |
| Ambient temperature | Sensor; Integrated type |
| Certification | Explosion-proof certificate |
| Flow-rate range | 0.5-10m/s |
| Grounding ring material | Stainless steel, molybdenum-containing stainless steel |
| Highest medium; temperature | Integrated type |
| Housing Material | Standard carbon steel, stainless steel needs to be customized |
| Model Number | NYLD-CH |
| Nominal diameter | 15~800mm |
| NOMINAL PRESSURE | Standard 1.0MPa |
| Protection Grade | Separate type IP68, IP65 |
| Signal Output | 4-20mA, |
No specification matches.
Last verification : 2026-11-02
Official documents and the technical data recorded for 15913103-00. For a missing document or a specific revision, our experts send it to you.
NYLD-CH electromagnetic heat meter from Nuoying, measuring the heat carried by a heat transfer fluid in heating or air conditioning systems.
| Parameter | Value |
|---|---|
| Accuracy | ±0.5%R, ±1%R (below DN200) |
| Ambient Humidity | 5%~95% |
| Ambient temperature | Sensor; Integrated type |
| Certification | Explosion-proof certificate |
| Flow-rate range | 0.5-10m/s |
| Grounding ring material | Stainless steel, molybdenum-containing stainless steel |
| Highest medium; temperature | Integrated type |
| Housing Material | Standard carbon steel, stainless steel needs to be customized |
| Model Number | NYLD-CH |
| Nominal diameter | 15~800mm |
| NOMINAL PRESSURE | Standard 1.0MPa |
| Protection Grade | Separate type IP68, IP65 |
| Signal Output | 4-20mA, |
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
Electromagnetic Heat Meter Flow Transmitter

Stainless Steel Electromagnetic Flow Transmitter 15mm - 800mm NYLL-CH

IP68 Intelligent Electromagnetic Flow Meter 0.1-10m/S 4-20mA

NYLD Tubular Electromagnetic Flow Meter High Reliability Modbus Protocol

Describe your application and constraints in a request.
What is recorded about the regulatory status and the life of this part.
| Current status | Status not stated |
| Key dates | Not recorded |
| Manufacturer part number | 15913103-00 |
| Manufacturer | Nuoying |
Electromagnetic Flow Meters
Insertion Electromagnetic Flowmeter
Price on request
Electromagnetic Flow Meters
Intelligent Electromagnetic Flowmeter DN10 to DN2000 · Ref. : AF-EMF89
Price on request
Electromagnetic Flow Meters
DN25 to DN400 Electromagnetic Heat Flowmeter · Ref. : MFE600H
Price on request
Electromagnetic Flow Meters
Electromagnetic flow meter
Price on request
With your consent, we use Google cookies to measure the site’s audience and our advertising. Your quote basket and comparison stay in your browser either way. Details