18957798-00
Low Pressure Differential Transmitter for Gas 0-10 V

- Operating Temperature
- -20℃~+60℃
- Pressure range
- 100pa-30kpa
- Measuring Range
- 100pa-40kpa
- Inherent frequency
- 5kHz~650kHz
Low Pressure Differential Transmitter for Gas 0-10 V
Low pressure differential transmitter for gases such as oxygen, air and wind, with 4-20 mA, 1-5 V, 0-10 V and RS485 outputs.
Overview. The NP-93420-DP differential pressure transmitter from Nuoying is a low pressure differential sensor designed for measuring gases, including oxygen, air and wind. It is a gas pressure transmitter built around an OEM silicon piezoresistive differential pressure core, housed in an aluminium alloy case.
Main characteristics. The pressure range runs from 100 Pa to 30 kPa for differential measurement, and measurement can be gauge or absolute pressure. Accuracy is 0.1 %, 0.25 % or 0.5 % of full scale depending on the version. Long-term stability is 0.2 % of full scale or less per year, and overload tolerance is 200 % of full scale.
Interfaces and connectivity. The transmitter provides 4-20 mA, 1-5 V, 0-10 V and RS485 outputs. Both pressure ports are M8 threaded and designed for an 8 mm inner diameter air pipe.
Power and environment. The supply voltage is 12 to 36 VDC, with a full load power of 2 W. The operating temperature is -20 °C to +60 °C, the medium temperature -40 °C to +80 °C and the environment temperature -40 °C to +85 °C. The protection grade is IP65 and the product carries the CE certification.
Typical uses. This transmitter suits pressure control in power and coal industry processes, such as boiler air supply and underground ventilation.
Integration. The high pressure is connected to the long tube and the low pressure to the short tube. For gauge pressure measurement, only the long tube is used.
No published question about this part yet. Questions are reviewed before publication.
Every characteristic recorded for 18957798-00, with where it comes from. Use the filters to find one quickly.
| Characteristic | Value |
|---|---|
| Pressure range | 100pa-30kpa |
| Accuracy | 0.1%F.S, 0.25%F.S, 0.5%F.S (standard) |
| Certification | CE |
| Compensation Temperature | -10~70℃ |
| Environment Temperature | -40~85℃ |
| Full Load Power: | 2W For Dp Pressure Transmitter For Oxygen |
| Inherent frequency | 5kHz~650kHz |
| Long-term stability | ≤ 0.2%F.S/year |
| Measuring media | Gaseous |
| Measuring medium | Gas Wind Oxygen Air |
| Measuring Range | 100pa-40kpa |
| Medium temperature | -40~80℃ |
| Model Number | NP-93420-DP |
| Operating Temperature | -20℃~+60℃ |
| Output signal | 4~20mA,1~5V, 0~10V, RS485 |
| Overload | 200%F.S |
| Power supply | 12-36VDC |
| Pressure Type | Gauge pressure, Absolute pressure |
| Protection Grade | IP65 |
| Sensitivity Temperature Drift | ±0.03%F.S/℃ |
| Warrenty | 1 years |
| Zero tempe drift | ±0.03%F.S/℃ |
No specification matches.
Last verification : 2026-11-02
Official documents and the technical data recorded for 18957798-00. For a missing document or a specific revision, our experts send it to you.
Low pressure differential transmitter for gases such as oxygen, air and wind, with 4-20 mA, 1-5 V, 0-10 V and RS485 outputs.
| Parameter | Value |
|---|---|
| Pressure range | 100pa-30kpa |
| Accuracy | 0.1%F.S, 0.25%F.S, 0.5%F.S (standard) |
| Certification | CE |
| Compensation Temperature | -10~70℃ |
| Environment Temperature | -40~85℃ |
| Full Load Power: | 2W For Dp Pressure Transmitter For Oxygen |
| Inherent frequency | 5kHz~650kHz |
| Long-term stability | ≤ 0.2%F.S/year |
| Measuring media | Gaseous |
| Measuring medium | Gas Wind Oxygen Air |
| Measuring Range | 100pa-40kpa |
| Medium temperature | -40~80℃ |
| Model Number | NP-93420-DP |
| Operating Temperature | -20℃~+60℃ |
| Output signal | 4~20mA,1~5V, 0~10V, RS485 |
| Overload | 200%F.S |
| Power supply | 12-36VDC |
| Pressure Type | Gauge pressure, Absolute pressure |
| Protection Grade | IP65 |
| Sensitivity Temperature Drift | ±0.03%F.S/℃ |
| Warrenty | 1 years |
| Zero tempe drift | ±0.03%F.S/℃ |
Points to check before using 18957798-00 in a design. They are derived from the recorded characteristics, not from the manufacturer's application circuits.
| Full Load Power: | 2W For Dp Pressure Transmitter For Oxygen |
| Power supply | 12-36VDC |
Check the exact pin assignment and the application circuit in the datasheet, or ask our experts.
Answers to the questions that the recorded characteristics of 18957798-00 can answer. A question is not asked when nothing is recorded to answer it.
Yes — recorded under "Output signal": 4~20mA,1~5V, 0~10V, RS485.
-20℃~+60℃ (source: Operating Temperature).
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
Low Pressure Differential Transmitter for Gas 0-10 V

NY3051 Adjustable Pressure Sensor Transmitter 0.1 - 16s 24VDC IP67

NP - 93420 Flange Pressure Sensor Transmitter High Sensitivity 20mA

3051 Intelligent Pressure Sensor Transmitter Liquid Gas Steam High Precision

Describe your application and constraints in a request.
What is recorded about the regulatory status and the life of this part.
| Current status | Status not stated |
| Key dates | Not recorded |
| Manufacturer part number | 18957798-00 |
| Manufacturer | Nuoying |
Pressure Sensor Modules
LoRaWAN pressure sensor, SS316 transducer
Price on request
Pressure Sensor Modules
High pressure sensor with digital I²C output · Ref. : MPM283I
Price on request
Pressure Sensor Modules
Thin film hydraulic pressure sensor 0-5 to 2000 bar · Ref. : HPT906
Price on request
Pressure Sensor Modules
Zigbee temperature, humidity and air pressure sensor · Ref. : 6979033600706
Price on request
With your consent, we use Google cookies to measure the site’s audience and our advertising. Your quote basket and comparison stay in your browser either way. Details