NYLD – Intelligent 4-20mA electromagnetic flow meter, high precision

Intelligent 4-20mA electromagnetic flow meter, high precision

Electromagnetic Flow Meters

  • 0.1-10m/s
  • Less than 20W
  • 5%~95%
  • -25~+60℃
Manufacturer part number
35635949-00
Manufacturer
Nuoying
Flow-rate range
0.1-10m/s
Total Power Consumption
Less than 20W

NYLD intelligent electromagnetic flow meter by Nuoying, made of a sensor and a converter, for measuring the volume flow of conductive liquids.

Product overview

Overview. The NYLD intelligent electromagnetic flow meter by Nuoying consists of a sensor and a converter. Based on Faraday's law of electromagnetic induction, it measures the volume flow of conductive liquids with a conductivity greater than or equal to 5 µs/cm.

Main characteristics. Flow range of 0.1 to 10 m/s, range ratio 20:1, positive and negative flow direction, and repeatability error of ±0.1% of the measured value. Accuracy grade 0.5 or 1.0 for the pipe type, 1.5 or 2.0 for the plug-in type.

Interfaces and connectivity. 4-20mA signal output (load resistance 0 to 750 Ω), pulse/frequency and control level output, RS485 communication with MODBUS protocol and HART communication interface.

Power and environment. Power supply 220 VAC or 24 VDC, total power consumption less than 20 W, protection grade IP65 customizable up to IP68, ambient temperature −25 to +60 °C, ambient humidity 5% to 95%. Lining options: normal rubber −20 to +60 °C, high temperature rubber −20 to +90 °C, PTFE −30 to +100 °C, high temperature tetrafluoro −20 to +180 °C. Explosion-proof grade Exd IIC T6, certified CE, ATEX and SIL.

Typical uses. Flow measurement of conductive liquids, including strongly corrosive liquids and uniform liquid-solid suspensions, in the petroleum, chemical, metallurgy, textile, papermaking, environmental protection and food industries, as well as municipal management and water conservancy.

Installation. Flange connection conforming to standard GB/T 9115.1. Required straight pipe length of 5 DN upstream and 2 DN downstream. Rated operating pressure of 1.6 MPa up to DN150, decreasing to 0.25 MPa for DN450 to DN2200, higher pressure available on request.

See all specifications

Highlights

  • Ambient Humidity: 5%~95%
  • Ambient temperature: -25~+60℃
  • Certification: CE,ATEX,SIL
  • Communication output: Rs485 communication MODBUS protocol, HART communication interface
  • Explosion-proof grade: ExdllСT6
  • Flow Direction:: Positive and negative