53386705-00
Electromagnetic flow meter for hot water and cool water

- Measuring Range
- ≤ 10 m/ s
- Storage Temperature
- -40~60℃
- Ambient temperature
- - 25℃ ~/+ 60℃
- Caliber
- DN 3~DN 600
Electromagnetic flow meter for hot water and cool water
Nuoying stainless steel flanged electromagnetic flow meter for hot water and cool water monitoring in DN 3 to DN 600 pipes.
Overview. The manufacturer Nuoying designs the NYLD-S, a flanged electromagnetic flow meter for hot water and cool water metering in DN 3~DN 600 pipelines. Operating from internal 3.6 V batteries, it measures fluid velocities up to 10 m/ s.
Measurement Performance. The meter features ± 0.5% accuracy for bidirectional flow with an internal 8-bit totalizer. Measurement readings are transmitted via an RS 485 communication link.
Materials and Protection. Fitted with 316 L electrodes and an IP68 submersible sensor withstand rating of 1.0M Pa, it supports fluid temperatures from - 25℃ ~/+ 80℃.
No published question about this part yet. Questions are reviewed before publication.
Every characteristic recorded for 53386705-00, with where it comes from. Use the filters to find one quickly.
| Characteristic | Value |
|---|---|
| alarm information | Battery-powered type electromagnetic flow meter can monitor the following alarms: air traffic control alarm, sensor fault (excitation open circuit), reverse flow, upper and lower flow alarm, and battery depletion.After programming the alarm, the instrument can display the corresponding alarm information after the above alarm and can indicate the alarm information to the computer computer through the communication interface. |
| Ambient temperature | - 25℃ ~/+ 60℃ |
| Battery Life | Over 5 years (2 batteries with 1 / 5 Hz response) |
| Caliber | DN 3~DN 600 |
| Certification | Explosion-proof certificate |
| Communication mode | RS 485 Communications |
| Conductivity | ≥ 20μ S/ cm |
| Data parameters | Instrument parameters and measurement data are stored in non-volatile memory (generally stored for 10 years)For the use requirements of measurement and settlement, the instrument has mechanical seal and electronic seal two devices can effectively prevent it; Parameters that determine measurement measurements are not modified by unauthorized persons. |
| Electrical Connection | M 20 X 1.5 Seal sleeve, G 1 / 2,1 / 2 NPT |
| Electrode material | 316 L, Harbin alloy, titanium, tantalum, platinum-iridium alloy, stainless steel coated with tungsten carbide |
| environmental effect | <±0. 1 %/ 10℃ |
| flange | Meet GB 9119 standard (standard), carbon steel (optional stainless steel), other standards to negotiate |
| Flow Direction: | Forward And Reverse |
| Installation Mode | DN40-DN300 (pipe Flange Type) |
| Internal cumulative calculator | For the total forward flow, the total and net reverse flow can achieve an 8-bit cumulative calculation. |
| intrinsic error | ± 0.5% of values value |
| Levels of Protection | IP 65 / IP 68 ( selectable) |
| lining material | Natural rubber, neoprene, polyurethane rubber, PFA, F 46, PTFE polytetrafluoroethylene, ETFE |
| Measuring Range | ≤ 10 m/ s |
| Medium temperature | - 25℃ ~/+ 80℃ |
| Model Number | NYLD-S |
| Power Supply Voltage | Built-in 2 to 519 Ah batteries, voltage of 3.6 V (battery exhausted and replaceable) |
| Pressure rating | DN3~DN600 1.0,1.6,2.5,4.0 Mpa |
| Programming | If the data is provided to the Company upon ordering, the relevant data will be prepared inside the converter before leaving the factory.When necessary, it is easy to reprogram the converter through the communication interface by the upper computer or the operator authorized by the user, and it will not affect the technical performance of the converter. |
| Protection against the external environment | One body size reaches IP67, divided into body size converter IP67, sensor IP68 |
| Protection Grade | IP68 |
| Rated Pressure | 1.0M Pa (special Pressure Can Be Customized) |
| Reactive mode | Excitation frequency of 1 / 15Hz; 2.5Hz excitation frequency; other optional |
| Repeatability Error | ≤ ±0. 25 % |
| show | Three lines of display: using 120 segment code display, can realize the flow speed, flow, total amount, billing, alarm information, battery power and other data and information display.Display content is selectable and can be switched without the magnetic spring switch to operating authentication. |
| Storage Temperature | -40~60℃ |
| Temperature | Operating environment temperature: -25℃ ~60℃ ;; Storage temperature: -25℃ ~60℃ |
No specification matches.
Last verification : 2026-11-02
Official documents and the technical data recorded for 53386705-00. For a missing document or a specific revision, our experts send it to you.
Nuoying stainless steel flanged electromagnetic flow meter for hot water and cool water monitoring in DN 3 to DN 600 pipes.
| Parameter | Value |
|---|---|
| alarm information | Battery-powered type electromagnetic flow meter can monitor the following alarms: air traffic control alarm, sensor fault (excitation open circuit), reverse flow, upper and lower flow alarm, and battery depletion.After programming the alarm, the instrument can display the corresponding alarm information after the above alarm and can indicate the alarm information to the computer computer through the communication interface. |
| Ambient temperature | - 25℃ ~/+ 60℃ |
| Battery Life | Over 5 years (2 batteries with 1 / 5 Hz response) |
| Caliber | DN 3~DN 600 |
| Certification | Explosion-proof certificate |
| Communication mode | RS 485 Communications |
| Conductivity | ≥ 20μ S/ cm |
| Data parameters | Instrument parameters and measurement data are stored in non-volatile memory (generally stored for 10 years)For the use requirements of measurement and settlement, the instrument has mechanical seal and electronic seal two devices can effectively prevent it; Parameters that determine measurement measurements are not modified by unauthorized persons. |
| Electrical Connection | M 20 X 1.5 Seal sleeve, G 1 / 2,1 / 2 NPT |
| Electrode material | 316 L, Harbin alloy, titanium, tantalum, platinum-iridium alloy, stainless steel coated with tungsten carbide |
| environmental effect | <±0. 1 %/ 10℃ |
| flange | Meet GB 9119 standard (standard), carbon steel (optional stainless steel), other standards to negotiate |
| Flow Direction: | Forward And Reverse |
| Installation Mode | DN40-DN300 (pipe Flange Type) |
| Internal cumulative calculator | For the total forward flow, the total and net reverse flow can achieve an 8-bit cumulative calculation. |
| intrinsic error | ± 0.5% of values value |
| Levels of Protection | IP 65 / IP 68 ( selectable) |
| lining material | Natural rubber, neoprene, polyurethane rubber, PFA, F 46, PTFE polytetrafluoroethylene, ETFE |
| Measuring Range | ≤ 10 m/ s |
| Medium temperature | - 25℃ ~/+ 80℃ |
| Model Number | NYLD-S |
| Power Supply Voltage | Built-in 2 to 519 Ah batteries, voltage of 3.6 V (battery exhausted and replaceable) |
| Pressure rating | DN3~DN600 1.0,1.6,2.5,4.0 Mpa |
| Programming | If the data is provided to the Company upon ordering, the relevant data will be prepared inside the converter before leaving the factory.When necessary, it is easy to reprogram the converter through the communication interface by the upper computer or the operator authorized by the user, and it will not affect the technical performance of the converter. |
| Protection against the external environment | One body size reaches IP67, divided into body size converter IP67, sensor IP68 |
| Protection Grade | IP68 |
| Rated Pressure | 1.0M Pa (special Pressure Can Be Customized) |
| Reactive mode | Excitation frequency of 1 / 15Hz; 2.5Hz excitation frequency; other optional |
| Repeatability Error | ≤ ±0. 25 % |
| show | Three lines of display: using 120 segment code display, can realize the flow speed, flow, total amount, billing, alarm information, battery power and other data and information display.Display content is selectable and can be switched without the magnetic spring switch to operating authentication. |
| Storage Temperature | -40~60℃ |
| Temperature | Operating environment temperature: -25℃ ~60℃ ;; Storage temperature: -25℃ ~60℃ |
Answers to the questions that the recorded characteristics of 53386705-00 can answer. A question is not asked when nothing is recorded to answer it.
Yes — recorded under "Communication mode": RS 485 Communications.
Yes — recorded under "alarm information": Battery-powered type electromagnetic flow meter can monitor the following alarms: air traffic control alarm, sensor fault (excitation open circuit), reverse flow, upper and lower flow alarm, and battery depletion.After programming the alarm, the instrument can display the corresponding alarm information after the above alarm and can indicate the alarm information to the computer computer through the communication interface..
Built-in 2 to 519 Ah batteries, voltage of 3.6 V (battery exhausted and replaceable) (source: Power Supply Voltage).
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
Electromagnetic flow meter for hot water and cool water

Flange Type Electromagnetic Flow Meter 1Mpa Forward Reverse

NYLD Intelligent Integrated Electromagnetic Flowmeter Water Flow Sensor 0.5% Accuracy for Waterworks Salt Water Flowmeter

NYLD Direct

Describe your application and constraints in a request.
What is recorded about the regulatory status and the life of this part.
| Current status | Status not stated |
| Key dates | Not recorded |
| Manufacturer part number | 53386705-00 |
| Manufacturer | Nuoying |
Electromagnetic Flow Meters
Insertion Electromagnetic Flowmeter
Price on request
Electromagnetic Flow Meters
Intelligent Electromagnetic Flowmeter DN10 to DN2000 · Ref. : AF-EMF89
Price on request
Electromagnetic Flow Meters
DN25 to DN400 Electromagnetic Heat Flowmeter · Ref. : MFE600H
Price on request
Electromagnetic Flow Meters
Electromagnetic flow meter
Price on request
No advertising or analytics cookies. A single, strictly necessary cookie is set only if you sign in to your account. Your quote basket and comparison stay in your browser. Details