PCAN-XL STARTER BUNDLE
Bus interface 16 channels

- Feature
- Connection with up to 16 CAN channels
- Feature
- Windows® 11 (x64/ARM64), 10 (x64)
- Feature
- CAN FD data bit rates up to 8 Mbit/s
- Feature
- Time stamp resolution 1 µs
Bus interface 16 channels
CAN and LIN Interface Adapters
Interface linking the host USB port to the equipment bus.
PCAN-XL Starter Bundle signal path. PEAK-System’s PCAN-XL Starter Bundle is a bus interface for CAN FD communication.
Operating characteristics. USB provides the host-side connection.
Bus diagnostics and isolation. The entry lists 16 channels. Galvanic isolation is specified up to 500 V.
No published question about this part yet. Questions are reviewed before publication.
Every characteristic recorded for PCAN-XL STARTER BUNDLE, with where it comes from. Use the filters to find one quickly.
| Characteristic | Value |
|---|---|
| Feature | CAN interface for High-speed USB 2.0 (compatible to USB 3.0) |
| Feature | Galvanic isolation between CAN and USB up to 500 V |
| Feature | Extended operating temperature range from -40 to +85 °C (-40 to +185 °F) |
| Feature | Connection with up to 16 CAN channels |
| Feature | Support for the CAN specifications CAN CC (classic CAN 2.0), CAN FD, and CAN XL (ISO 11898-1 2024) |
| Feature | Creating CAN XL send messages with selection of an SDT (service data unit type) according to CiA® 611-1, such as tunneling of CAN FD frames |
| Feature | Windows® 11 (x64/ARM64), 10 (x64) |
| Feature | IPEH-005001: One PCAN-USB XL interface unit |
| Feature | IPEH-005002: Two PCAN-USB XL interface units |
| Feature | Device drivers for Windows® 11 (x64/ARM64), 10 (x64) |
| Feature | Professional CAN analysis software PCAN-Explorer 7 Early Access for Windows® with copy protection dongle |
| Feature | High-speed CAN connection (ISO 11898-2 2024) Complies with CAN specifications CAN CC (classic CAN 2.0), CAN FD, and CAN XL (ISO 11898-1 2024) |
| Feature | CAN bit rates from 20 kbit/s up to 1 Mbit/s |
| Feature | CAN FD data bit rates up to 8 Mbit/s |
| Feature | CAN XL data bit rates up to 8 Mbit/s, CAN FD compatible transmission mode |
| Feature | CAN XL data bit rates up to 20 Mbit/s by using the transceiver mode switch |
| Feature | CAN bus connection via D-Sub, 9-pin (in accordance with CiA® 106) |
| Feature | Time stamp resolution 1 µs |
| Feature | CAN SIC XL transceiver TI TCAN6062V |
No specification matches.
Last verification : 2026-11-25
Official documents and the technical data recorded for PCAN-XL STARTER BUNDLE. For a missing document or a specific revision, our experts send it to you.
Interface linking the host USB port to the equipment bus.
| Parameter | Value |
|---|---|
| Feature | CAN interface for High-speed USB 2.0 (compatible to USB 3.0) |
| Feature | Galvanic isolation between CAN and USB up to 500 V |
| Feature | Extended operating temperature range from -40 to +85 °C (-40 to +185 °F) |
| Feature | Connection with up to 16 CAN channels |
| Feature | Support for the CAN specifications CAN CC (classic CAN 2.0), CAN FD, and CAN XL (ISO 11898-1 2024) |
| Feature | Creating CAN XL send messages with selection of an SDT (service data unit type) according to CiA® 611-1, such as tunneling of CAN FD frames |
| Feature | Windows® 11 (x64/ARM64), 10 (x64) |
| Feature | IPEH-005001: One PCAN-USB XL interface unit |
| Feature | IPEH-005002: Two PCAN-USB XL interface units |
| Feature | Device drivers for Windows® 11 (x64/ARM64), 10 (x64) |
| Feature | Professional CAN analysis software PCAN-Explorer 7 Early Access for Windows® with copy protection dongle |
| Feature | High-speed CAN connection (ISO 11898-2 2024) Complies with CAN specifications CAN CC (classic CAN 2.0), CAN FD, and CAN XL (ISO 11898-1 2024) |
| Feature | CAN bit rates from 20 kbit/s up to 1 Mbit/s |
| Feature | CAN FD data bit rates up to 8 Mbit/s |
| Feature | CAN XL data bit rates up to 8 Mbit/s, CAN FD compatible transmission mode |
| Feature | CAN XL data bit rates up to 20 Mbit/s by using the transceiver mode switch |
| Feature | CAN bus connection via D-Sub, 9-pin (in accordance with CiA® 106) |
| Feature | Time stamp resolution 1 µs |
| Feature | CAN SIC XL transceiver TI TCAN6062V |
Answers to the questions that the recorded characteristics of PCAN-XL STARTER BUNDLE can answer. A question is not asked when nothing is recorded to answer it.
Yes — recorded under "Feature": CAN interface for High-speed USB 2.0 (compatible to USB 3.0).
Yes — recorded under "Feature": CAN interface for High-speed USB 2.0 (compatible to USB 3.0).
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
Bus interface 16 channels


USB to CAN Analyzer Adapter with USB Cable

Kvaser

Describe your application and constraints in a request.
What is recorded about the regulatory status and the life of this part.
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
| Current status | Status not stated |
| Key dates | Not recorded |
| Manufacturer part number | PCAN-XL STARTER BUNDLE |
| Manufacturer | PEAK-System |
CAN and LIN Interface Adapters
USB interface for CAN/CAN FD 1 channel M12
Price on request
CAN and LIN Interface Adapters
Bus interface CAN FD / CAN XL / USB
Price on request
CAN and LIN Interface Adapters
USB interface for CAN/CAN FD 1 channel D-SUB 9
Price on request
CAN and LIN Interface Adapters
Bus interface CAN FD / USB
Price on request
No advertising or analytics cookies. A single, strictly necessary cookie is set only if you sign in to your account. Your quote basket and comparison stay in your browser. Details