MANUFACTURER
PEAK-System
PEAK-System is a manufacturer. Atlas Electronics lists PEAK-System products in 4 categories, including Industrial Protocol Converters, CAN and LIN Interface Adapters, Mixed Signal I/O Modules. 177 manufacturer documents (datasheets, manuals, certificates) are linked to the product pages. Prices and lead times on quotation.
Product families
Technologies
Matched from product names, summaries and categories.
Products
| Quote basket | Action | |||||||||
|---|---|---|---|---|---|---|---|---|---|---|
| PCAN-GPS FD | PEAK-System | PCAN-GPS FD | NXP LPC54618 microcontroller with Arm® Cortex® M4 core | 3.3 V supply for active GPS antennas | Electronic three-axis magnetic field sensor IIS2MDC from ST | Gyroscope and three-axis accelerometer ISM330DLC from ST | 8 MByte QSPI flash | Status not stated | Quote | |
| PCAN-MICROMOD MIX 3 | PEAK-System | PCAN-MicroMod Mix 3 | High-speed CAN connection (ISO 11898-2) Bit rates from 10 kbit/s up to 1 Mbit/s | Protection against under- and overvoltage | Low pass behavior | 8 digital inputs: Schmitt trigger behavior, inverting | Threshold High = 4.8 V, Low = 1.2 V | Status not stated | Quote | |
| PCAN-REPEATER | PEAK-System | PCAN-Repeater | Two High-speed CAN ports (ISO 11898-2) Comply with CAN specifications CAN CC (classic CAN 2.0) and CAN FD (ISO and non-ISO) | Transit delay about 175 ns, which corresponds to a cable length of approximately 35 m | Voltage supply from 10 to 30 V | Plastic housing (width: 27 mm) for mounting on a DIN rail (EN 50022 standard) | Extended operating temperature range from -40 to +85 °C (-40 to +185 °F) | Status not stated | Quote | |
| PCAN-MICROMOD FD | PEAK-System | PCAN-MicroMod FD | Plug-in board with 2 double pin strips of 50 pins each, 50 mil pitch (1.27 mm) | 8 digital outputs | 2 frequency outputs | Selective configuration of up to 16 devices in a CAN network based on the module ID | Voltage supply 3.3 V | Status not stated | Quote | |
| PCAN-ETHERNET GATEWAY DR | PEAK-System | PCAN-Ethernet Gateway DR | Two High-speed CAN channels (ISO 11898-2) Comply with CAN specifications 2.0 A/B | Software update via the web interface | Reboot and reset of the device to factory defaults with a reset button | Plastic casing (width: 22.5 mm) for mounting on a DIN rail (DIN EN 60715 TH35) | LEDs for device status and power supply | Status not stated | Quote | |
| PCAN-MICROMOD FD DR CANOPEN DIGITAL 1 | PEAK-System | PCAN-MicroMod FD DR CANopen Digital 1 | I/O module for CANopen® and CANopen FD® Communication profiles according to CiA® 301 version 4.2.0 and CiA® 1301 version 1.1.0 | Input characteristics: Type 3 | 2 groups of 4 inputs to be used either as sourcing or sinking inputs | Galvanic isolation of the digital inputs 0 to 3 and 4 to 7 each up to 100 V against the module supply | 8 digital outputs 500 mA load per High-side output | Status not stated | Quote | |
| PCAN-DIAG FD J1939 ADD-IN | PEAK-System | PCAN-Diag FD J1939 Add-in | Support of the SAE J1939 standard | – | – | – | – | Status not stated | Quote | |
| PCAN-MINIDISPLAY | PEAK-System | PCAN-MiniDisplay | CAN connections via two High-speed CAN channels (ISO 11898-2) Bit rates from 40 kbit/s up to 1 Mbit/s | Display of bitmap images with transparency | Signal-dependent display of image lists | Presentation of multiple signal curves in plotters | Configurable access to key and buzzer functions as well as display brightness via CAN | Status not stated | Quote | |
| PCAN-RS-232 | PEAK-System | PCAN-RS-232 | NXP LPC21 series microcontroller (16/32-bit ARM CPU) | Extended operating temperature range from -40 to +85 °C (-40 to +185 °F) | New firmware can be loaded via CAN interface | – | – | Status not stated | Quote | |
| PCAN-ROUTER PRO FD | PEAK-System | PCAN-Router Pro FD | 6 High-speed CAN channels (ISO 11898-2) Comply with CAN specifications 2.0 A/B and FD | 2 digital I/Os, each usable as digital input or output with Low-side switch | 1 analog input (0 to 32 V) | Recording of CAN data and error frames | Internal memory: 16 GByte pSLC eMMC | Status not stated | Quote | |
| PCAN-DIAG FD | PEAK-System | PCAN-Diag FD | High-speed CAN connection (ISO 11898-2) Complies with CAN specifications 2.0 A/B and FD | Power supply via the internal rechargeable batteries or the provided supply unit (low-voltage socket on unit) | Charging of the batteries is carried out with external supply, even during operation | Charging station with quick-charging function available as an option (IPEH-003068) | Internal memory card for saving projects. Can also be used as a USB mass storage device when connected to a PC | Status not stated | Quote | |
| PCAN-MICROMOD DIGITAL 1 & 2 | PEAK-System | PCAN-MicroMod Digital 1 & 2 | High-speed CAN connection (ISO 11898-2) Bit rates from 10 kbit/s up to 1 Mbit/s | Threshold High = 4.8 V, Low = 1.2 V | Low pass behaviour | Parallel connection of frequency inputs at 4 digital inputs for alternative use (e.g. on rapid state changes, counting) | 5 digital outputs: PCAN-MicroMod Digital 1: 4 Low-side switch, max. 45 V, 0.35 A | Status not stated | Quote | |
| PCAN-MICROMOD ANALOG 1 & 2 | PEAK-System | PCAN-MicroMod Analog 1 & 2 | High-speed CAN connection (ISO 11898-2) Bit rates from 10 kbit/s up to 1 Mbit/s | Measuring range extension optional | Pull-down circuit | Protection against under- and overvoltages | Parallel connection of a digital input each for alternative use (e.g. push buttons) | Status not stated | Quote | |
| PCAN-GPS PRO FD | PEAK-System | PCAN-GPS Pro FD | STM32H745 microcontroller with Arm® Cortex® M7 and M4 dual core and 2 MByte flash | Simultaneous reception of 4 navigation systems | Maximum update rate 25 Hz | Configurable supply of active GPS antennas with 3.3 V or 5 V | Optional direct access to the u-blox via USB | Status not stated | Quote | |
| PCAN-ROUTER FD | PEAK-System | PCAN-Router FD | NXP LPC4078 microcontroller (ARM Cortex M4 with FPU, 120 MHz) | Connections via two 9-pin D-Sub connectors or one 10-pole screw-terminal strip (Phoenix) | RS-232 connector for serial data transfer | I/O connection: One digital input (Low-active) | One digital output (Low-side switch, max. 600 mA) | Status not stated | Quote | |
| PCAN-DIAG 2 | PEAK-System | PCAN-Diag 2 | High-speed CAN (ISO 11898-2) Complies with CAN specifications 2.0 A/B | Selection of the bit rate from a preset list or from 8 user-defined values | Automatic bit rate detection based on a fixed value list | Switchable listen-only mode | Switchable silent startup function (listen-only mode at wrong bit rate) | Status not stated | Quote | |
| PCAN-MICROMOD FD ECU | PEAK-System | PCAN-MicroMod FD ECU | Module with integrated PCAN-MicroMod FD | Measuring range adjustable: ±2.5 V, ±5 V, ±10 V, ±20 V | 4 of the analog inputs alternatively usable as analog output Resolution 12 bit | Voltage range adjustable: 0 to 5 V or 0 to 10 V | 2 frequency outputs Low-side switches (3 A) | Status not stated | Quote | |
| PAE-MEDIA CONVERTER | PEAK-System | PAE-Media Converter | Standard Ethernet connection: 100BASE-TX / 1000BASE-T according to IEEE 802.3u / 802.3ab | Aluminum profile housing with flange, front and rear panels made of composite materials | LEDs for device status and power supply | Extended operating temperature range from -40 to +85 °C (to +70 °C for product version 1.0 ) | – | Status not stated | Quote | |
| PCAN-MICROMOD FD ANALOG 1 | PEAK-System | PCAN-MicroMod FD Analog 1 | Board with plugged on PCAN-MicroMod FD | Measuring range adjustable: ±2.5 V, ±5 V, ±10 V, ±20 V | 4 analog inputs Resolution 12 bit | Measuring range 0 to 10 V | 4 analog outputs Resolution 12 bit | Status not stated | Quote | |
| MU-THERMOCOUPLE1 CAN FD | PEAK-System | MU-Thermocouple1 CAN FD | 8 Mini sockets for thermocouple types J, K, or T | CAN FD bit rates for the data field (64 bytes max.) from 25 kbit/s up to 10 Mbit/s | CAN bit rates from 25 kbit/s up to 1 Mbit/s | NXP TJA1044GT CAN transceiver | Galvanic isolation up to 500 V | Status not stated | Quote | |
| PCAN-ROUTER | PEAK-System | PCAN-Router | NXP LPC21 series microcontroller (16/32-bit ARM CPU) | Voltage supply from 8 to 30 V | Extended operating temperature range from -40 to +85 °C (-40 to +185 °F) | New firmware can be loaded via CAN interface | – | Status not stated | Quote | |
| PCAN-REPEATER DR | PEAK-System | PCAN-Repeater DR | Two High-speed CAN ports (ISO 11898-2) Compliant with CAN specifications 2.0A (11-bit ID) and 2.0B (29-bit ID) | Voltage supply from 8 to 30 V | Plastic housing (width: 22.5 mm) for mounting on a DIN rail (DIN EN 60715 TH35) | Extended operating temperature range from -40 to +85 °C (-40 to +185 °F) | – | Status not stated | Quote | |
| PCAN-ROUTER DR | PEAK-System | PCAN-Router DR | NXP LPC21 series microcontroller (16/32-bit ARM CPU) | CAN 1 is isolated up to 5 kV against CAN 2, RS-232, and the power supply (compliant with IEC 60601-1) | CAN 2 and RS-232 are isolated with 500 V against each other and against the power supply | Plastic casing (width: 22.5 mm) for mounting on a DIN rail (DIN EN 60715 TH35) | Voltage supply from 8 to 30 V | Status not stated | Quote | |
| MU-THERMOCOUPLE1 CAN | PEAK-System | MU-Thermocouple1 CAN | 8 Mini sockets for thermocouple types J, K, and T | Galvanic isolation up to 500 V | NXP TJA1040 CAN transceiver | Complies with CAN specifications 2.0 A/B | Basic configuration with the Windows® software Thermocouple Configuration | Status not stated | Quote | |
| PCAN-MINIDIAG FD | PEAK-System | PCAN-MiniDiag FD | High-speed CAN connection (ISO 11898-2) Complies with CAN specifications 2.0 A/B and FD | Operation via membrane keypad with four keys | Plastic casing with increased Ingress Protection IP42 | Dimensions: 122 x 69 x 44 mm | Operating temperature range from -10 to +50 °C (14 to 122 °F) | Status not stated | Quote | |
| PCAN-MICROMOD FD DIGITAL 1&2 | PEAK-System | PCAN-MicroMod FD Digital 1&2 | Board with plugged on PCAN-MicroMod FD | 8 digital outputs Digital 1: Low-side switches | Digital 2: High-side switches | PWM mode: resolution duty cycle 16 bit, adjustable frequency range from 0 to 20 kHz | 3 analog inputs Resolution 12 bit | Status not stated | Quote | |
| PCAN-ETHERNET GATEWAY FD DR | PEAK-System | PCAN-Ethernet Gateway FD DR | Two High-speed CAN channels (ISO 11898-2) Comply with CAN specifications 2.0 A/B and FD | Monitoring and configuration of the devices via the web interface or JSON interface | Software update via the web interface | Reboot or reset of the device to a previous software version with a reset button | Plastic casing (width: 45.2 mm) for mounting on a DIN rail (DIN EN 60715 TH35) | Status not stated | Quote | |
| PCAN-OPTOADAPTER | PEAK-System | PCAN-Optoadapter | Plug-on adapter for decoupling a CAN bus for PEAK CAN interfaces | Extended operating temperature range from -40 to +85 °C (-40 to +185 °F) | – | – | – | Status not stated | Quote | |
| PCAN-USB XL | PEAK-System | PCAN-USB XL | CAN interface for High-speed USB 2.0 (compatible to USB 3.0) | CAN SIC XL transceiver TI TCAN6062V | Galvanic isolation between CAN and USB up to 500 V | CAN termination can be activated through solder jumpers | Voltage supply via USB | Status not stated | Quote | |
| PCAN-MICROMOD | PEAK-System | PCAN-MicroMod | High-speed CAN connection (ISO 11898-2) Bit rates from 10 kbit/s up to 1 Mbit/s | – | – | – | – | Status not stated | Quote | |
| PCAN-ROUTER PRO | PEAK-System | PCAN-Router Pro | 4 High-speed CAN channels (ISO 11898-2) Comply with CAN specifications 2.0 A/B | Status LEDs for CAN channels, CompactFlash card, microcontroller, and power supply | NXP microcontroller LPC2294 | Aluminum casing with flange. DIN rail fixing option available on request | 8 to 27 V power supply, protection against overvoltage and reverse polarity | Status not stated | Quote | |
| PCAN-MICROMOD MIX 1 & 2 | PEAK-System | PCAN-MicroMod Mix 1 & 2 | High-speed CAN connection (ISO 11898-2) Bit rates from 10 kbit/s up to 1 Mbit/s | Measuring range extension optional | Pull-down circuit | Protection against under- and overvoltages | 2 temperature inputs: 2 connections for NTC resistors (type EC95F103W) | Status not stated | Quote | |
| PCAN-RS-232 FD | PEAK-System | PCAN-RS-232 FD | NXP LPC54618 microcontroller with Arm® Cortex® M4 core | 8 MByte QSPI flash | 2 digital I/Os, each usable as input (High-active) or output with Low-side switch | 2-color LED for status signaling | Connection via a 10-pole terminal strip (Phoenix) | Status not stated | Quote | |
| PCAN-USB FD | PEAK-System | PCAN-USB FD | CAN interface for High-speed USB 2.0 (compatible to USB 1.1 and USB 3.0; available with USB-A or USB-C connector) | NXP TJA1044GT CAN transceiver | Galvanic isolation up to 500 V | CAN termination can be activated through a solder jumper | Measurement of bus load including error frames and overload frames on the physical bus | Status not stated | Quote | |
| PCAN-USB PRO FD | PEAK-System | PCAN-USB Pro FD | Adapter for High-speed USB 2.0 (compatible to USB 1.1 and USB 3.0) | CAN bit rates from 25 kbit/s up to 1 Mbit/s | FPGA implementation of the CAN FD controller | NXP TJA1044GT CAN transceiver | Each CAN FD channel is separately opto-decoupled against USB and LIN up to 500 V | Status not stated | Quote | |
| PCAN-PC/104-PLUS QUAD | PEAK-System | PCAN-PC/104-Plus Quad | Form factor PC/104 | Galvanic isolation on the CAN connection up to 500 V, separate for each CAN channel | 5-Volt supply to the CAN connection can be connected through a solder jumper, e.g. for external bus converter | Extended operating temperature range from -40 to +85 °C (-40 to +185 °F) | Optionally available: PC/104-ISA stack-through connector | Status not stated | Quote | |
| PCAN-USB X6 | PEAK-System | PCAN-USB X6 | CAN-FD interface for High-speed USB 2.0 (compatible to USB 1.1 and USB 3.0) | Status LEDs for CAN channels, USB upstream, and power supply | CAN connection via D-Sub, 9-pin or M12 circular connectors, 5-pin (pin assignment of both connectors in accordance with CiA® 106) | Aluminum casing with increased Ingress Protection IP64 (only for IPEH-004063) | High-speed USB 2.0 downstream port (only for IPEH-004062 and IPEH-004064) | Status not stated | Quote | |
| PCAN-PCI EXPRESS | PEAK-System | PCAN-PCI Express | PC plug-in card (PCIe-x1) for PCI Express slots | Extended operating temperature range from -40 to +85 °C (-40 to +185 °F) | – | – | – | Status not stated | Quote | |
| PCAN-MINIPCIE FD | PEAK-System | PCAN-miniPCIe FD | CAN interface for the PCI Express Mini slot (uses PCIe lane) | NXP TJA1044GT CAN transceiver | Galvanic isolation on the CAN connection up to 300 V, separate for each CAN channel | CAN termination can be activated through solder jumpers, separately for each CAN channel | PCIe data transfer via bus master DMA | Status not stated | Quote | |
| PCAN-TJA1054 | PEAK-System | PCAN-TJA1054 | Adapter from High-speed CAN to Low-speed CAN | – | – | – | – | Status not stated | Quote | |
| PCAN-PCI/104-EXPRESS | PEAK-System | PCAN-PCI/104-Express | PCI/104-Express card, 1 lane (x1) | Galvanic isolation on the CAN connection up to 500 V, separate for each CAN channel | Supplied only via the 5 V line | 5-Volt supply to the CAN connection can be connected through a solder jumper, e.g. for external bus converter | Extended operating temperature range from -40 to +85 °C (-40 to +185 °F) | Status not stated | Quote | |
| PCAN-PCI EXPRESS FD | PEAK-System | PCAN-PCI Express FD | PC plug-in card (PCIe x1) for PCI Express slots | Galvanic isolation on the CAN connection up to 500 V, separate for each CAN channel | CAN termination can be activated through solder jumpers, separately for each CAN channel | PCIe data transfer via bus master DMA | DMA memory access operations with 32- and 64-bit addresses | Status not stated | Quote | |
| PCAN-PCI/104-EXPRESS FD | PEAK-System | PCAN-PCI/104-Express FD | PCI/104-Express card, 1 lane (x1) | FPGA implementation of the CAN FD controller | Microchip CAN transceiver MCP2558FD | Galvanic isolation on the CAN connection up to 500 V, separate for each CAN channel | CAN termination can be activated through solder jumpers, separately for each CAN channel | Status not stated | Quote | |
| PCAN-MINIPCIE | PEAK-System | PCAN-miniPCIe | CAN interface for the PCI Express Mini slot (uses PCIe lane) | – | – | – | – | Status not stated | Quote | |
| PCAN-PC/104-PLUS | PEAK-System | PCAN-PC/104-Plus | Form factor PC/104 | 5-Volt supply to the CAN connection can be connected through a solder jumper, e.g. for external bus converter | Galvanic isolation on the CAN connection up to 500 V, separate for each CAN channel (only for IPEH-002096 and IPEH-002097) | Extended operating temperature range from -40 to +85 °C (-40 to +185 °F) | Optionally available: PC/104-ISA stack-through connector | Status not stated | Quote | |
| PCAN-GPS | PEAK-System | PCAN-GPS | NXP LPC4000 series microcontroller (ARM Cortex-M4) | 2 digital inputs (High-active) | 1 digital output (Low-side driver) | LEDs for status signaling | Connection via a 10-pole terminal strip (Phoenix) | Status not stated | Quote | |
| PCAN-LIN | PEAK-System | PCAN-LIN | General-purpose gateway (or router when using Acceptance Code / Acceptance Mask feature) from: RS-232 to LIN (and back) | Processing a user-definable LIN ID list (scheduler with limited number of entries) | Individual LIN frames can be initiated via CAN or RS-232 | Voltage supply from 9 to 30 V | Extended operating temperature range from -40 to +85 °C (-40 to +185 °F) | Status not stated | Quote | |
| PCAN-LWL | PEAK-System | PCAN-LWL | LED display for transceiver status | Supply via D-Sub 9-pin or DC connector (jumper) | Operating temperature range from 0 to 70 °C (32 to 158 °F) | – | – | Status not stated | Quote | |
| PCAN-MIO | PEAK-System | PCAN-MIO | 2 High-speed CAN channels (ISO 11898-2) Comply with CAN specifications 2.0 A/B | Suitable for use in the automotive field | Detailed configuration with the software PPCAN-Editor 2 for Windows® | Module can store up to 15 configurations | CAN gateway between buses | Status not stated | Quote | |
| PLIN-USB | PEAK-System | PLIN-USB | LIN interface for the USB connection (Full-Speed mode, compatible with USB 1.1, USB 2.0, and USB 3.0) | NXP LIN transceiver TJA1028T or TI LIN transceiver TLIN1028D | Galvanic isolation on the LIN connection up to 500 V | Indicator LED for interface status | Voltage supply 5 V DC via USB port | Status not stated | Quote |
Documents
177 documents · 176 manual · 1 datasheet · Browse all in the document center
- PCAN-PC/104-Plus Quad — German PCAN-PC/104-PLUS QUAD
- PCAN-MicroMod FD Analog 1 — English PCAN-MICROMOD FD ANALOG 1
- PCAN-MicroMod FD Analog 1 — English PCAN-MICROMOD FD ANALOG 1
- MU-Thermocouple1 CAN — English MU-THERMOCOUPLE1 CAN
- PCAN-PCI/104-Express FD — German PCAN-PCI/104-EXPRESS FD
- PCAN-Ethernet Gateway DR — German PCAN-ETHERNET GATEWAY DR
- PCAN-USB — German PCAN-USB
- PCAN-PCI Express FD — German PCAN-PCI EXPRESS FD
8 of 177 documents shown. See all
Frequently asked questions about PEAK-System
Which PEAK-System products does Atlas Electronics list?
Products in 4 categories, mainly Industrial Protocol Converters, CAN and LIN Interface Adapters, Mixed Signal I/O Modules.
How do I get a price for a PEAK-System product?
Prices and lead times are given on quotation: use "Request a quote" on a product page, or add several references to your quote request.
Where can I find PEAK-System datasheets?
177 manufacturer documents are linked: in the Documents tab of each product and in the document center.


