| Environmental parameters — Humidity | 5%–95% RH non-condensing |
| Environmental parameters — IP and IK rating | IP55/IK10 |
| Environmental parameters — Lightning protection | Level C |
| Environmental parameters — Operating altitude | ≤2000m |
| Environmental; Parameters — Operating Temperature | –20°C~+50°C |
| Environmental; Parameters — Storage Temperature | –40°C~+75°C |
| Input
parameters — AC Power supply | 1P+N |
| Input
parameters — AC Voltage | 230V(±10%) |
| Input
parameters — DC Voltage | 150-1000VDC |
| Input
parameters — Description — PEVC3302E/U- SPOT-N1 | PEVC3302E/U- SPOT-D2 |
| Input
parameters — Frequency | 50/60Hz |
| Others — Communication | Ethernet/4G |
| Others — Compliance | IEC61851-1,IEC61851-23,IEC61851-21-2 |
| Others — Cooling system | Forced air cooling |
| Others — DC Cable length | 5m |
| Others — Dimensions (D*W*H) | 450x400×1600mm |
| Others — Dimensions (D x W x H) | 1600x850x2000mm |
| Others — Emergency stop | √ |
| Others — Enclosure type | Galvanized sheet steel |
| Others — HMI | 7-inch touchscreen |
| Others — Insulation monitoring | √ |
| Others — Interface protocol | CAN(alternative:RS485) |
| Others — Operational noise level | ≤65dB |
| Others — Over temperature protection | √ |
| Others — Over voltage | √ |
| Others — Power distribution mode | Dynamic flexibility distribution |
| Others — Power meter | Accuracy Class 1.0 energy meter |
| Others — RCD | √ |
| Others — Reverse polarity protection | √ |
| Others — Short circuit | √ |
| Others — Surge protection | √ |
| Others — Under voltage | √ |
| Others — weight | 700kg |
| Others — Weight — 70kg | 85kg |
| Output
parameters — Connector | CCS1/CCS2 |
| Output
parameters — Current accuracy | ≤1% |
| Output
parameters — Maximum current | 500A |
| Output
parameters — Maximum current per channel | 250A |
| Output
parameters — Maximum power | 480kW |
| Output
parameters — Maximum power per channel | 250kW |
| Output
parameters — Number of Output Ports | 8(max) |
| Output
parameters — Output power | 480kW |
| Output
parameters — Voltage | 150-1000VDC |
| Output
parameters — Voltage accuracy | ≤0.5% |
| Parameter type — Description | PEVC3302E/U-SPOT-N1 |
| Parameter type
Input
parameters — AC Power supply | 3P+N+PE |
| Parameter type
Input
parameters — AC Voltage | 400VAC±10% |
| Parameter type
Input
parameters — Description | PEVC3302E/U-RCAB-480KW |
| Parameter type
Input
parameters — Efficiency | ≥95%(load: 50%–100%) |
| Parameter type
Input
parameters — Frequency | 50/60Hz |
| Parameter type
Input
parameters — Power factor | ≥0.99(load: 50%–100%) |
| Parameter type
Input
parameters — THDi | ≤5% |
| Protection
functions — Emergency stop | √ |
| Protection
functions — Insulation monitoring | √ |
| Protection
functions — Over current | √ |
| Protection
functions — Over temperature protection | √ |
| Protection
functions — Over voltage | √ |
| Protection
functions — RCD | √ |
| Protection
functions — Reverse polarity protection | √ |
| Protection
functions — Short circuit | √ |
| Protection
functions — Surge protection | √ |
| Protection
functions — Under voltage | √ |
| Safety
protection — Impulse voltage | ≥2500VDC |
| Safety
protection — Insulation resistance | ≥10MΩ |