ULB16 – NB-IoT Water Level Monitoring Kit with Stainless Steel Sensor 0~5 mH2O

NB-IoT Water Level Monitoring Kit with Stainless Steel Sensor 0~5 mH2O

Environmental Sensor Nodes

  • 0~70℃
  • -30~+100℃
  • 0~5mH2O
  • 6m
Manufacturer part number
C16028
Manufacturer
RAKwireless
Operating Temperature Range
-30~+100℃
Pressure ranges
0~5mH2O

RAKwireless kit measuring liquid level with the ULB16 stainless steel sensor, 0~5 mH2O range, and a Sensor Hub gateway with NB-IoT and LoRa connectivity for monitoring tanks, reservoirs, water or sewage.

Product overview

Overview. The RAKwireless Water Level Monitoring kit combines the RAKwireless Sensor Hub with the ULB16 stainless steel level sensor for liquid level measurement in petrochemical, hydrology, water tank or sewage applications, with a 0~5 mH2O measuring range.

Main characteristics. Accuracy is 0.25%FS as standard or 0.5%FS, with long-term stability below 0.1%FS per year. Overload pressure is 200%FS and the compensated temperature range is 0~70℃. The sensor operates from -30~+100℃.

Interfaces and connectivity. This version communicates over NB-IoT and LoRa in the 863-930MHz band and ships with a US power plug. The kit supports the CAT M1 and CAT NB2 categories. The sensor to ProbeIO cable is 6 m long. A splitter cable connects several probes to one Sensor Hub port, and an extension cable increases the distance between the hub and the probes.

Power. With a Sensor Probe IO and a connected sensor, the Sensor Hub cannot run on batteries and uses the included power supply, here with a US power plug.

Integration. The NB-IoT and LoRa outputs allow level measurements to be transmitted to a remote network or supervision platform.

See all specifications

Highlights

  • Accuracy: 0.25%FS (standard), 0.5%FS
  • Cable Length (Sensor to ProbeIO): 6m
  • Compensated temperature range: 0~70℃
  • Connectivity: NB-IoT
  • Frequency and Power Plug: 863-930MHz with US Power Plug
  • Long-term stability: <0.1%FS/year

Typical applications

Derived from the part category, not a compatibility statement.

Good to know before integrating

  • Thermal: rated operating range -30~+100℃ — check it against the installation environment.