Single-phase two-wire active energy meter in DIN rail format, 86 x 18.5 x 62 mm, for measuring electricity consumption on a 230 V, 50 Hz network.
Temperature rangeOperation: -25 55℃
Voltage Range80%Un 115%Un
Communication interfaceRS485 with screw type(optional)
I/O interface1 Output port(optional)
Current circuit apparent power at Ib<4VA
Maximum current Imax80A/100A
Product overview
Overview. The Reallin 264633200 single-phase two-wire DIN rail meter measures active energy on a single-phase network rated 230 V at 50 Hz. It is a class B DIN rail energy meter compliant with standards EN 50470-1 and EN 50470-3.
Main characteristics. The device shows consumption on a 6-digit LCD display and has an LED pulsating indicator. Its voltage range runs from 80% to 115% of Un, with a rated voltage of 230 V and a rated frequency of 50 Hz. The reference current Ib is 5 A, the maximum current Imax is 80 A/100 A and the minimum current Imin is 0.2 A. The starting current Ist is 0.4% Ib. The meter constant is 1000 imp/kWh.
Interfaces and connectivity. A pulse output is available as an option, as well as an RS485 communication interface with screw terminals (optional).
Power and environment. Power consumption of the voltage circuit is below 2 W and 10 VA at Un, and that of the current circuit below 4 VA at Ib. The operating temperature range is -25 to 55 °C. The protection degree is IP 51 in a protective enclosure, and the insulation class is II.
Dimensions and installation. The meter measures 86.0 x 18.5 x 62.0 mm and weighs about 0.1 kg. It mounts on a DIN rail.
Single-phase two-wire active energy meter in DIN rail format, 86 x 18.5 x 62 mm, for measuring electricity consumption on a 230 V, 50 Hz network.
Temperature rangeOperation: -25 55℃
Voltage Range80%Un 115%Un
Communication interfaceRS485 with screw type(optional)
I/O interface1 Output port(optional)
Current circuit apparent power at Ib<4VA
2. Datasheet extract (recorded values)
Parameter
Value
Accuracy
Class B for Active
Communication interface
RS485 with screw type(optional)
Current circuit apparent power at Ib
<4VA
Dimension(LxWxD)
86.0 x 18.5 x 62.0mm
Environment
1000imp/kWh
I/O interface
1 Output port(optional)
Insulation Class
II
LCD display
6 digits
Maximum current Imax
80A/100A
Minimum Current (Imin)
0.2A
Protection degree
IP 51 in protective enclosure
Pulsating Indicator
LED
Rated Frequency Fn
50Hz
Rated Voltage Un
230V
Reference current Ib
5A
Standards
EN 50470-1, EN 50470-3
Starting Current (Ist)
0.4%Ib
Temperature range
Operation: -25 55℃
Type
Single Phase Two Wire DIN Rail Meter
Voltage circuit active/apparent power at Un
<2W/10VA
Voltage Range
80%Un 115%Un
Weight Of Meter
About 0.1kg
Applications and use cases
Architectures in which 264633200 can play a role, derived from its category. This is not a compatibility statement: check the specifications against your requirements.
Energy bills give one total for the whole site. Submetering places meters and current sensors on each circuit or usage and collects their readings through a gateway, so consumption can be followed per building, floor or machine
To check
Number of circuits and phases to meter, and the current range of each
Wired Modbus bus or wireless LoRaWAN, depending on cabling access in the switchboards
Accuracy class required for internal allocation or for billing
A building’s energy, comfort and occupancy data sit in separate systems. Sensors, meters and gateways feed one model of the building, room by room, to compare scenarios and steer the installations
To check
Data model and building plans available
Software platform hosting the twin
Sensor density needed for a useful model
Associated system blocks
SensorsMetersGateways
Need a complete solution?
Send a request for 264633200 and the other parts of your project.
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
What is recorded about the regulatory status and the life of this part.
Regulatory compliance
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
With your consent, we use Google cookies to measure the site’s audience and our advertising. Your quote basket and comparison stay in your browser either way. Details