Single-phase two-wire active energy meter for DIN rail mounting, designed to measure consumption on a 230 V 50 Hz network in distribution boards.
Temperature rangeOperation: -25 55℃
Voltage Range80%Un 115%Un
Communication interfaceRS485 with screw type(optional)
I/O interface1 Output port(optional)
Current circuit apparent power at Ib<4VA
Maximum current Imax80A/100A
Product overview
The Reallin DIN RAIL KWH Meter Single Phase is a two-wire single-phase active energy meter for DIN rail mounting, compliant with EN 50470-1 and EN 50470-3, intended for energy measurement in distribution boards.
Main characteristics. Class B accuracy for active energy, rated voltage Un of 230 V, rated frequency Fn of 50 Hz, reference current Ib of 5 A and maximum current Imax of 80 A/100 A, minimum current Imin of 0.2 A and starting current of 0.4% Ib. Voltage range from 80% Un to 115% Un.
Display and signalling. 6-digit LCD display and LED pulsating indicator. Meter constant of 1000 imp/kWh.
Interfaces and communication. Optional pulse output and optional RS485 communication with screw-type terminals, for connection to a remote meter reading system or a PLC.
Power and environment. Voltage circuit consumption below 2 W and 10 VA at Un, current circuit apparent power below 4 VA at Ib. Operating temperature from -25 to 55 °C, protection degree IP 51 in protective enclosure, insulation class II. Dimensions 86.0 x 18.5 x 62.0 mm, weight about 0.1 kg.
Typical uses. Energy metering of a single-phase circuit in an electrical cabinet, with local reading or transmission of pulses and data to a supervision system.
Single-phase two-wire active energy meter for DIN rail mounting, designed to measure consumption on a 230 V 50 Hz network in distribution boards.
Temperature rangeOperation: -25 55℃
Voltage Range80%Un 115%Un
Communication interfaceRS485 with screw type(optional)
I/O interface1 Output port(optional)
Current circuit apparent power at Ib<4VA
2. Datasheet extract (recorded values)
Parameter
Value
Accuracy
Class B for Active
Communication interface
RS485 with screw type(optional)
Current circuit apparent power at Ib
<4VA
Dimension(LxWxD)
86.0 x 18.5 x 62.0mm
Environment
1000imp/kWh
I/O interface
1 Output port(optional)
Insulation Class
II
LCD display
6 digits
Maximum current Imax
80A/100A
Minimum Current (Imin)
0.2A
Protection degree
IP 51 in protective enclosure
Pulsating Indicator
LED
Rated Frequency Fn
50Hz
Rated Voltage Un
230V
Reference current Ib
5A
Standards
EN 50470-1, EN 50470-3
Starting Current (Ist)
0.4%Ib
Temperature range
Operation: -25 55℃
Type
Single Phase Two Wire DIN Rail Meter
Voltage circuit active/apparent power at Un
<2W/10VA
Voltage Range
80%Un 115%Un
Weight Of Meter
About 0.1kg
Applications and use cases
Architectures in which 264637103 can play a role, derived from its category. This is not a compatibility statement: check the specifications against your requirements.
Energy bills give one total for the whole site. Submetering places meters and current sensors on each circuit or usage and collects their readings through a gateway, so consumption can be followed per building, floor or machine
To check
Number of circuits and phases to meter, and the current range of each
Wired Modbus bus or wireless LoRaWAN, depending on cabling access in the switchboards
Accuracy class required for internal allocation or for billing
A building’s energy, comfort and occupancy data sit in separate systems. Sensors, meters and gateways feed one model of the building, room by room, to compare scenarios and steer the installations
To check
Data model and building plans available
Software platform hosting the twin
Sensor density needed for a useful model
Associated system blocks
SensorsMetersGateways
Need a complete solution?
Send a request for 264637103 and the other parts of your project.
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
Current productReallin
264637103
Single-phase DIN rail energy meter, pulse output and RS485
What is recorded about the regulatory status and the life of this part.
Regulatory compliance
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
With your consent, we use Google cookies to measure the site’s audience and our advertising. Your quote basket and comparison stay in your browser either way. Details