274491114 – Single-phase smart energy meter with optical port and DLMS

Single-phase smart energy meter with optical port and DLMS

Single-Phase Energy Meters

  • Operation:-25~60℃
  • 80%Un~115%Un
  • 1*Optical port
  • 1*Output
Manufacturer part number
274491114
Manufacturer
Reallin
Temperature range
Operation:-25~60℃
Voltage Range
80%Un~115%Un

Reallin single-phase smart energy meter for remote reading of electricity consumption on a 220 V, 50 Hz network. It includes a disconnect relay and a pulse output.

Product overview

Overview. The Reallin single-phase smart energy meter is a smart meter dedicated to measuring active and reactive energy on a 220 V, 50 Hz single-phase network. It is supplied with a reference voltage of 220 V, a reference current Ib of 5 A and a maximum current Imax of 60, 80 or 100 A depending on the version.

Measurement characteristics. Accuracy is class 1.0 for active energy and class 2.0 for reactive energy. The starting current Ist is 0.4% Ib and the minimum current Imin is 0.25 A. The meter constant is 1000 imp/kWh for active energy and 1000 imp/kvarh for reactive energy. The real-time clock RTC complies with IEC 62054-21.

Display and indication. The 7-digit LCD display has a configurable decimal position and backlight. An LED flashes at the rate of the measurement pulses.

Interfaces and communication. The meter provides one optical communication port and one I/O output. It communicates using the DLMS protocol and complies with IEC 62056-21, -42, -53, -61 and -62.

Load control and safety. A built-in latching relay is provided for load control. Backup power relies on a replaceable battery and an internal super capacitor.

Environment and standards. The housing has insulation class II and protection degree IP54, measures 160.2 × 112.0 × 79.0 mm and weighs about 1.0 kg. The operating temperature range is -25 to 60 °C and the permissible voltage range is 80% to 115% Un. The meter complies with IEC 62052-11 and -31, IEC 62053-21 and -23:2020, IEC 62055-41 and -51 and OIML R46.

Integration. With the DLMS protocol and optical port, the meter can be connected to a remote meter reading system for automatic data collection. Available on quotation from Atlas Electronics.

See all specifications

Highlights

  • Backup Power: Replaceable battery and Internal super capacitor
  • Communication interface: 1*Optical port
  • Communication Protocol: DLMS
  • Current circuit apparent power at Ib: <1VA
  • Dimension(LxWxD): 160.2×112.0×79.0mm
  • I/O interface: 1*Output

Typical applications

Derived from the part category, not a compatibility statement.

See also

Technical questions

Ask a question

No published question about this part yet. Questions are reviewed before publication.

Request a quote