274732154 – Single-phase two-wire smart energy meter

Single-phase two-wire smart energy meter

Single-Phase Energy Meters

  • Operation:-25~60℃
  • 80%Un~115%Un
  • 1*Optical port
  • 1*Output
Manufacturer part number
274732154
Manufacturer
Reallin
Temperature range
Operation:-25~60℃
Voltage Range
80%Un~115%Un

Single-phase two-wire smart energy meter for 220 V, 50 Hz networks, intended for homes and single-phase installations, measuring active and reactive energy with DLMS communication.

Product overview

Overview. The Reallin single-phase two-wire smart meter is an energy meter designed for single-phase supplies, for example in residential areas. It measures active and reactive energy on a 220 V rated voltage network at 50 Hz.

Metering characteristics. The accuracy class is 1.0 for active energy and 2.0 for reactive energy. The reference current Ib is 5 A, the maximum current Imax is 60/80/100 A and the minimum current Imin is 0.25 A, with a starting current Ist of 0.4% Ib. The meter constant is 1000 imp/kWh and 1000 imp/kvarh. The 7-digit LCD display has a configurable number of decimal places and backlight.

Interfaces and communication. The meter provides one optical communication port and one input/output interface. It supports the DLMS protocol and complies with IEC62056-21/42/53/61/62 for communication and remote meter reading. A built-in latching relay enables load control.

Power and environment. The operating voltage range is 80% Un to 115% Un. Consumption is below 2 W and 10 VA on the voltage circuit and below 1 VA on the current circuit. The RTC clock accuracy complies with IEC62054-21. Backup power is provided by a replaceable battery and an internal super capacitor. The operating temperature range is -25 to 60 °C and the protection degree is IP54. The insulation class is II. The weight is about 1.0 kg and the dimensions are 160.2 × 112.0 × 79.0 mm.

Standards. The meter complies with IEC 62052-11/31, IEC 62053-21/23:2020, IEC 62055-41/51 and OIML R46.

Use. This meter suits single-phase two-wire installations where remote consumption monitoring is required, with possible integration into a supervision system through the DLMS protocol.

See all specifications

Highlights

  • Backup Power: Replaceable battery and Internal super capacitor
  • Communication interface: 1*Optical port
  • Communication Protocol: DLMS
  • Current circuit apparent power at Ib: <1VA
  • Dimension(LxWxD): 160.2×112.0×79.0mm
  • I/O interface: 1*Output

Typical applications

Derived from the part category, not a compatibility statement.

See also

Technical questions

Ask a question

No published question about this part yet. Questions are reviewed before publication.

Request a quote