Smart three-phase energy meter rated 3x230/400 V for measuring and recording active and reactive energy consumption, with an RS485 output for remote meter reading.
Temperature rangeoperation:-40-70℃
Voltage Range70%un~140%un
Communication interfaceRS485 port,up to38400 b ps
Current circuit apparent power at Ib<1VA
Maximum current Imax80A
Minimum Current (Imin)0.25A
Product overview
Reallin, smart three-phase energy meter. The Reallin smart three-phase energy meter measures and records energy consumption in a three-phase AC system, with a backlit dot matrix LCD display.
Measurement characteristics. It is designed for a rated voltage of 3x230/400 V and a frequency of 50 Hz, with a voltage range of 70% to 140% of Un. The reference current is 5 A, the maximum current 80 A and the minimum current 0.25 A, with a starting current of 0.4% Ib. Accuracy is class B/1.0 for active energy and class 2.0 for reactive energy. The pulse constant is 1000 imp/kWh and 1000 imp/kvarh, indicated by an LED pulsing indicator.
Interfaces and communication. The meter provides an RS485 port up to 38400 bps for remote meter reading and integration into an existing reading system.
Power and environment. The voltage circuit consumption is 1.5 W / 8 VA or less, and the current circuit apparent power at Ib is less than 1 VA. The operating temperature range is -40 to 70 °C, and the protection degree is IP51 in a protective enclosure. Insulation class is II.
Typical uses and integration. Suited to measuring energy consumption on a three-phase network, it integrates with meter reading systems through its RS485 port. Dimensions 90 x 52.5 x 62 mm, weight about 0.3 kg. Standards: EN 50470-3:2022, IEC 62053-21/23:2020, IEC 62052-31:2015, UL61010-1 and UL61010-2-030. Available on quotation from Atlas Electronics.
Smart three-phase energy meter rated 3x230/400 V for measuring and recording active and reactive energy consumption, with an RS485 output for remote meter reading.
Temperature rangeoperation:-40-70℃
Voltage Range70%un~140%un
Communication interfaceRS485 port,up to38400 b ps
Current circuit apparent power at Ib<1VA
Maximum current Imax80A
2. Datasheet extract (recorded values)
Parameter
Value
Accuracy
class B/1.0 for active; class 2.0 for reactive
Communication interface
RS485 port,up to38400 b ps
Current circuit apparent power at Ib
<1VA
Dimension(LXW XD)
90x52.5x62mm
Insulation Class
II
LCD display
Dot Matrix type,backlight supported
Maximum current Imax
80A
Minimum Current (Imin)
0.25A
port ect ion Degree
IP51 in protective enclosure
Pulsating Indicator
LED
Pulsating(meter constant)
1000 imp/kwh; 1000 imp/kvarh
Rated Frequency Fn
50HZ
Rated Voltage Un
3x230/400v
Reference current Ib
5A
Standards
EN 50470-3:2022,IEC 62053-21/23:2020,IEC 62052-31:2015,UL61010-1,UL61010-2-030
Starting Current (Ist)
0.4%Ib
Temperature range
operation:-40-70℃
voltage circuit active lap parent power atun
≤ 1.5W/8VA
Voltage Range
70%un~140%un
Weight Of Meter
About0.3kg
Applications and use cases
Architectures in which 282180158 can play a role, derived from its category. This is not a compatibility statement: check the specifications against your requirements.
Energy bills give one total for the whole site. Submetering places meters and current sensors on each circuit or usage and collects their readings through a gateway, so consumption can be followed per building, floor or machine
To check
Number of circuits and phases to meter, and the current range of each
Wired Modbus bus or wireless LoRaWAN, depending on cabling access in the switchboards
Accuracy class required for internal allocation or for billing
Solar production, storage and charging points on one site are often managed separately. Inverters, batteries, MPPT controllers, meters and chargers form a local energy system that shares production between users
To check
Regulatory framework for collective self-consumption in the country
Energy management system steering storage and charging
Metering accuracy for sharing between participants
Associated system blocks
ProductionStorageMeteringCharging
Need a complete solution?
Send a request for 282180158 and the other parts of your project.
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
Current productReallin
282180158
Smart three-phase energy meter with RS485, class B
What is recorded about the regulatory status and the life of this part.
Regulatory compliance
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
With your consent, we use Google cookies to measure the site’s audience and our advertising. Your quote basket and comparison stay in your browser either way. Details