ATMOSPHERIC-PRESSURE-SENSOR
Atmospheric pressure sensor 0 to 120 kPa with LCD display

- Operating Temperature
- -40℃~+60℃, 0%RH~95%RH (non-condensing)
- Measure range
- 0~120kPa
- Max. power consumption — 0.5W
- 1.2W
- Accuracy
- ±0.15kPa@25℃ 101kPa
Atmospheric pressure sensor 0 to 120 kPa with LCD display
Wall-mounted Renke atmospheric pressure sensor measuring 0 to 120 kPa, with LCD display and RS485 output, for agricultural, industrial and weather station monitoring.
Renke RS-QY-*-2D-LCD-T. the Renke RS-QY-*-2D-LCD-T atmospheric pressure sensor measures air pressure over a range of 0 to 120 kPa and can therefore be applied at various altitudes.
Main characteristics. the sensor uses an imported high-precision measuring unit with built-in high-precision temperature compensation, an accuracy of ±0.15 kPa at 25 ℃ for 101 kPa, a response time of 2 s or less and a long-term stability of -0.1 kPa per year.
Connectivity and outputs. the RS485 output (485-A and 485-B signals) transmits the data, and an analogue output of 4 to 20 mA, 0 to 5 V or 0 to 10 V is available. Measured data can also be shown directly on the LCD screen or uploaded to a free cloud platform via the RS485 signal.
Power and environment. 10 to 30 V DC power supply, maximum power consumption of 1.2 W, operating temperature of -40 ℃ to +60 ℃ and 0 %RH to 95 %RH (non-condensing).
Typical uses. altimeters, agricultural greenhouses, weather stations and archives, where atmospheric pressure measurement is required.
Integration. the housing has a slide rail mounting plate that supports wall mounting or guide rail mounting. On the RS485 bus, the A and B lines must not be reversed and the device addresses must not conflict. For 0 to 10 V output equipment, only a 24 V power supply can be used.
No published question about this part yet. Questions are reviewed before publication.
Every characteristic recorded for ATMOSPHERIC-PRESSURE-SENSOR, with where it comes from. Use the filters to find one quickly.
| Characteristic | Value |
|---|---|
| Response time | ≤2s |
| Accuracy | ±0.15kPa@25℃ 101kPa |
| Communication — 485A | 485-A |
| Communication — 485B | 485-B |
| Load Capacity | resistance ≤ 250Ω, current ≤ 600Ω |
| Long-term stability | -0.1kPa/year |
| Max. power consumption — 0.5W | 1.2W |
| Measure range | 0~120kPa |
| Model | RS-QY-*-2D-LCD-T |
| Operating Temperature | -40℃~+60℃, 0%RH~95%RH (non-condensing) |
| Output — RH | Atmospheric pressure signal positive |
| Output — RS485 | 4~20mA/0~5V/0~10V |
| Output — TH | Reserved |
| Power supply | 10~30V DC |
| Power supply — GND | Negative power supply |
| Power supply (Vcc) | Positive power supply (10~30V DC) |
No specification matches.
Last verification : 2026-11-02
Official documents and the technical data recorded for ATMOSPHERIC-PRESSURE-SENSOR. For a missing document or a specific revision, our experts send it to you.
Wall-mounted Renke atmospheric pressure sensor measuring 0 to 120 kPa, with LCD display and RS485 output, for agricultural, industrial and weather station monitoring.
| Parameter | Value |
|---|---|
| Response time | ≤2s |
| Accuracy | ±0.15kPa@25℃ 101kPa |
| Communication — 485A | 485-A |
| Communication — 485B | 485-B |
| Load Capacity | resistance ≤ 250Ω, current ≤ 600Ω |
| Long-term stability | -0.1kPa/year |
| Max. power consumption — 0.5W | 1.2W |
| Measure range | 0~120kPa |
| Model | RS-QY-*-2D-LCD-T |
| Operating Temperature | -40℃~+60℃, 0%RH~95%RH (non-condensing) |
| Output — RH | Atmospheric pressure signal positive |
| Output — RS485 | 4~20mA/0~5V/0~10V |
| Output — TH | Reserved |
| Power supply | 10~30V DC |
| Power supply — GND | Negative power supply |
| Power supply (Vcc) | Positive power supply (10~30V DC) |
Points to check before using ATMOSPHERIC-PRESSURE-SENSOR in a design. They are derived from the recorded characteristics, not from the manufacturer's application circuits.
| Max. power consumption — 0.5W | 1.2W |
| Power supply | 10~30V DC |
| Power supply — GND | Negative power supply |
| Power supply (Vcc) | Positive power supply (10~30V DC) |
Check the exact pin assignment and the application circuit in the datasheet, or ask our experts.
Answers to the questions that the recorded characteristics of ATMOSPHERIC-PRESSURE-SENSOR can answer. A question is not asked when nothing is recorded to answer it.
Yes — recorded under "Output — RS485": 4~20mA/0~5V/0~10V.
-40℃~+60℃, 0%RH~95%RH (non-condensing) (source: Operating Temperature).
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
Atmospheric pressure sensor 0 to 120 kPa with LCD display

RS485 Air Temperature, Humidity and BarometricPressure Sensor(S-THP-01A) - Seeed Studio

0.2 Inch Thin Film Resistor type Pressure Sensor - FSR400 A301

Water Pressure Sensor G1/4 1.2MPa

Describe your application and constraints in a request.
What is recorded about the regulatory status and the life of this part.
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
| Current status | Status not stated |
| Key dates | Not recorded |
| Manufacturer part number | ATMOSPHERIC-PRESSURE-SENSOR |
| Manufacturer | Renke |
Pressure Sensor Modules
LoRaWAN pressure sensor, SS316 transducer
Price on request
Pressure Sensor Modules
High pressure sensor with digital I²C output · Ref. : MPM283I
Price on request
Pressure Sensor Modules
Thin film hydraulic pressure sensor 0-5 to 2000 bar · Ref. : HPT906
Price on request
Pressure Sensor Modules
Zigbee temperature, humidity and air pressure sensor · Ref. : 6979033600706
Price on request
With your consent, we use Google cookies to measure the site’s audience and our advertising. Your quote basket and comparison stay in your browser either way. Details