RS-WS-*-SMG-*-T – Digital temperature and humidity sensor with RS485 and analog outputs

Digital temperature and humidity sensor with RS485 and analog outputs

Temperature Sensor Modules

  • -40℃~+80℃, 0%RH-100%RH
  • 1s
  • DC 10-30V
  • 0.1℃, 0.1%RH
Manufacturer part number
DIGITAL-TEMPERATURE-AND-HUMIDITY-SENSOR
Manufacturer
Renke
Measuring Range
-40℃~+80℃, 0%RH-100%RH
Data refresh time
1s

Wall-mounted digital temperature and humidity sensor with LCD display, measuring -40℃ to +80℃ and 0 to 100 %RH, with RS485 and analog outputs.

Product overview

Renke RS-WS-*-SMG-*-T digital temperature and humidity sensor — wired wall-mounted sensor with LCD display, offering RS485, 4-20mA, 0-5V and 0-10V outputs.

Measurement. Measuring range from -40℃ to +80℃ for temperature and 0 %RH to 100 %RH for humidity. Accuracy of ±0.5℃ at 25℃ and ±3 %RH at 60 %RH and 25℃, resolution of 0.1℃ and 0.1 %RH, data refresh time of 1 s.

Stability and response. Long-term stability of 0.1℃ per year or less for temperature and 1 %RH per year or less for humidity. Temperature response time of 25 s or less and humidity response time of 8 s or less, at a wind speed of 1 m/s.

Connectivity. RS485, 4-20mA, 0-5V and 0-10V outputs. Modbus is listed in the manufacturer data, allowing integration into an existing RS485 network.

Power and environment. DC power supply of 10 to 30 V. Working environment from -40℃ to +60℃ and 0 %RH to 95 %RH, non-condensing.

Construction. High-brightness LCD display housing, temperature and humidity probe at the lower end, IP68-rated PG7 cable gland at the cable outlet, conformal-coated circuit board and integrated anti-interference module. The probe can be replaced, for example with a high-temperature probe or a waterproof probe for measuring in liquids.

Typical uses. Monitoring of temperature and humidity indoors or in sheltered outdoor locations, with transmission to a PLC or supervision system via RS485 or analog signals.

See all specifications

Highlights

  • Response time: Temperature≤25s (1m/s wind speed²), Humidity≤8s (1m/s wind speed²)
  • Accuracy: ±0.5℃ (25℃), ±3%RH(60%RH,25℃)
  • Data refresh time: 1s
  • Long-term stability: Temperature≤0.1℃/y, Humidity≤1%RH/y
  • Measuring Range: -40℃~+80℃, 0%RH-100%RH
  • Model: RS-WS-*-SMG-*-T

Typical applications

Derived from the part category, not a compatibility statement.

See also

Technical questions

Ask a question

No published question about this part yet. Questions are reviewed before publication.

Request a quote