RS-MG41-CO2-T – Portable CO2 Meter with NDIR Sensor and Natural Diffusion

Portable CO2 Meter with NDIR Sensor and Natural Diffusion

CO2 Sensors

  • Diffusion type ≤60S
  • 6h – 8h
  • ≥20MΩ
  • ≤2%
Manufacturer part number
HANDHELD-CO2-METER
Manufacturer
Renke
Response time
Diffusion type ≤60S
Alarm functions
Sound, Light, Vibration

Portable CO2 meter with an NDIR sensor and a 0 to 5000 ppm range, designed for air quality checks and verification of carbon dioxide atmospheres.

Product overview

Overview. The Renke RS-MG41-CO2-T is a portable CO2 meter that measures carbon dioxide concentration by natural diffusion using a built-in non-dispersive infrared (NDIR) sensor. The manufacturer describes it as an intrinsically safe gas meter.

Main characteristics. The measurement range is 0 to 5000 ppm, with an effective range of 400 to 5000 ppm and a resolution of 1 ppm. Accuracy is ±(50 ppm + 3 %F·S) at 25 ℃ for 400 to 5000 ppm, repeatability is ≤2 % and stability is ≤2 %FS. Response time in diffusion mode is ≤60 s.

Alarm and display. When the configured threshold is exceeded, the instrument triggers a three-level alarm combining sound, light and vibration. Its high-definition colour display remains readable in dark environments.

Data storage. The instrument stores up to 100,000 records, which can be reviewed in the history and exported via USB as Excel, PDF or TXT files.

Power and environment. It operates at DC 3.7 V from a 3000 mAh lithium battery, with standby time greater than 24 h continuous. Charging takes 6 to 8 h through a Micro-B port supplied at 5 V DC. Operating environment is -10 ℃ to 50 ℃, below 95 % RH, non-condensing. Insulation resistance is ≥20 MΩ.

Typical uses. This portable instrument complements fixed monitoring systems where these do not cover every space, for example checking tanks during brewing and fermentation, verifying clearance after discharge of a CO2 total flooding fire suppression system, testing the atmosphere before entering a wastewater treatment manhole, or pre-entry testing of enclosed spaces.

See all specifications

Highlights

  • Response time: Diffusion type ≤60S
  • Accuracy: ±(50ppm + 3%F·S) @(25℃, 400~5000ppm)
  • Alarm functions: Sound, Light, Vibration
  • Charging Time: 6h – 8h
  • Insulation Resistance: ≥20MΩ
  • Measurement Range: 0~5000ppm (effective range: 400-5000ppm)

Typical applications

Derived from the part category, not a compatibility statement.