Renke relative humidity and temperature sensor for wall or rail mounting, with RS485 or analog output, for measuring and monitoring ambient conditions.
Temperature range-40℃~+80℃
Humidity range0%RH-100%RH
Circuit working environment-20℃~+60℃, 0%RH~95%RH (non-condensing)
Hole size70mm
Long-term stability — Humidity≤1%RH/y
Long-term stability — Temperature≤0.1℃/y
Product overview
Overview. The Renke RS-WS-*-2D-*-T temperature and humidity sensor measures the temperature and relative humidity of air, with an accuracy of ±0.5℃ (25℃) and ±3%RH (60%RH, 25℃) for the built-in probe. It is offered with RS485, 4-20mA, 0-5V or 0-10V output and, optionally, an LCD display.
Main characteristics. Humidity measuring range from 0%RH to 100%RH and temperature range from -40℃ to +80℃. Resolution of 0.1℃ and 0.1%RH. Response time of ≤8s for humidity and ≤25s for temperature (wind speed of 1 m/s). Long-term stability: ≤1%RH/y for humidity and ≤0.1℃/y for temperature. External probe accuracy: ±0.4℃ (25℃) and ±2%RH (60%RH, 25℃).
Interfaces and connectivity. RS485 or analog 4-20mA, 0-5V and 0-10V signal outputs depending on the configuration. Compatible with an optional USB to RS485 converter and a 485 terminal resistance.
Power and environment. DC 10 to 30 V power supply. Circuit working environment from -20℃ to +60℃ and from 0%RH to 95%RH, non-condensing. Fully enclosed IP65 housing protecting the sensor from dust and moisture. Hole size of 70 mm.
Typical uses. Temperature and humidity monitoring in industrial and residential buildings and in public places. The RS485 output allows connection to a supervision system, and the analog outputs to a PLC or a recorder.
Integration. Wall or rail mounting. A free data platform allows remote monitoring by PC or application.
No published question about this part yet. Questions are reviewed before publication.
Complete specifications
Every characteristic recorded for TEMPERATURE-HUMIDITY-SENSOR, with where it comes from. Use the filters to find one quickly.
All specifications (14)
Characteristic
Value
Humidity range
0%RH-100%RH
Circuit working environment
-20℃~+60℃, 0%RH~95%RH (non-condensing)
Hole size
70mm
Long-term stability — Humidity
≤1%RH/y
Long-term stability — Temperature
≤0.1℃/y
Model
RS-WS-*-2D-*-T
Output signal
RS485, 4-20mA, 0-5V, 0-10V
Power supply
DC 10~30V
Precision — Built-in probe
±0.5℃ (25℃), ±3%RH (60%RH,25℃)
Precision — External probe
±0.4℃ (25℃), ±2%RH (60%RH, 25℃)
Resolution
0.1℃, 0.1%RH
Response time — Humidity
≤8s (1m/s wind speed²)
Response time — Temperature
≤25s (1m/s wind speed²)
Temperature range
-40℃~+80℃
No specification matches.
Last verification : 2026-11-02
Technical documentation
Official documents and the technical data recorded for TEMPERATURE-HUMIDITY-SENSOR. For a missing document or a specific revision, our experts send it to you.
Renke relative humidity and temperature sensor for wall or rail mounting, with RS485 or analog output, for measuring and monitoring ambient conditions.
Temperature range-40℃~+80℃
Humidity range0%RH-100%RH
Circuit working environment-20℃~+60℃, 0%RH~95%RH (non-condensing)
Hole size70mm
Long-term stability — Humidity≤1%RH/y
2. Datasheet extract (recorded values)
Parameter
Value
Humidity range
0%RH-100%RH
Circuit working environment
-20℃~+60℃, 0%RH~95%RH (non-condensing)
Hole size
70mm
Long-term stability — Humidity
≤1%RH/y
Long-term stability — Temperature
≤0.1℃/y
Model
RS-WS-*-2D-*-T
Output signal
RS485, 4-20mA, 0-5V, 0-10V
Power supply
DC 10~30V
Precision — Built-in probe
±0.5℃ (25℃), ±3%RH (60%RH,25℃)
Precision — External probe
±0.4℃ (25℃), ±2%RH (60%RH, 25℃)
Resolution
0.1℃, 0.1%RH
Response time — Humidity
≤8s (1m/s wind speed²)
Response time — Temperature
≤25s (1m/s wind speed²)
Temperature range
-40℃~+80℃
Applications and use cases
Architectures in which TEMPERATURE-HUMIDITY-SENSOR can play a role, derived from its category. This is not a compatibility statement: check the specifications against your requirements.
A fridge that drifts at night can ruin a whole stock. Temperature loggers in cold rooms and trucks report through a gateway or a tracker and raise an alert when a threshold is crossed
To check
Temperature range and accuracy required by the product
Record keeping required by the applicable regulations
A building’s energy, comfort and occupancy data sit in separate systems. Sensors, meters and gateways feed one model of the building, room by room, to compare scenarios and steer the installations
To check
Data model and building plans available
Software platform hosting the twin
Sensor density needed for a useful model
Associated system blocks
SensorsMetersGateways
Need a complete solution?
Send a request for TEMPERATURE-HUMIDITY-SENSOR and the other parts of your project.
Answers to the questions that the recorded characteristics of TEMPERATURE-HUMIDITY-SENSOR can answer. A question is not asked when nothing is recorded to answer it.
1Does it support RS-485?
Yes — recorded under "Output signal": RS485, 4-20mA, 0-5V, 0-10V.
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
What is recorded about the regulatory status and the life of this part.
Regulatory compliance
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
No advertising or analytics cookies. A single, strictly necessary cookie is set only if you sign in to your account. Your quote basket and comparison stay in your browser. Details