Single-axis CANopen tilt sensor measuring tilt and pitch angles relative to the horizontal plane for harsh industrial control environments.
Response timePARAMETER: 0.02; UNIT: s
Long-term stabilityPARAMETER: 0.05; UNIT: °
Measure axisPARAMETER: X/Y; UNIT: Axis
Power-on start timePARAMETER: 0.5; UNIT: S
ResolutionPARAMETER: 0.01; UNIT: °
Store temp.MIN: -40; MAX: +85; UNIT: ℃
Product overview
Overview. The Rion SCA116T-CANOPEN is a single-axis tilt sensor with CANopen output for industrial control. It outputs the tilt and pitch angle relative to the horizontal plane.
Main characteristics. Available measuring ranges are ±10°, ±30°, ±60° and ±90°, measured on the X and Y axes. Measurement accuracy at 25 °C is 0.02°, 0.03°, 0.05° or 0.06° depending on the range, resolution is 0.01° and long-term stability is 0.05°. The zero temperature coefficient is ±0.006°/°C between -40 and 85 °C, and response time is 0.02 s. The output rate can be set to 5 Hz, 15 Hz, 35 Hz or 50 Hz.
Interfaces and connectivity. The output is CANopen. The standard one-metre cable is shielded, 4 × 0.4 mm², wear-resistant, oil-proof and suitable for a wide temperature range. The sensor complies with EN61000 and GBT17626 for electromagnetic compatibility.
Power and environment. The supply voltage ranges from 9 to 36 V, with typical values of 12 and 24 V. The typical working current without load is 40 mA. The sensor has an IP67 protection grade, operates between -40 and +85 °C and is stored between -40 and +85 °C. It withstands a 100 g shock of 11 ms along three axes (half sinusoid) and vibrations of 10 grms between 10 and 1000 Hz. Insulation resistance is at least 100 MΩ and MTBF is at least 50,000 hours. Weight is at most 220 g, including the one-metre cable.
Typical uses. Tilt monitoring on railway locomotives, inclination measurement on construction machinery, geological tilt monitoring, oil drilling equipment, ship navigation and attitude measurement, and shield pipe jacking.
Integration. The sensor connects to a CANopen bus. Its power-on start time is 0.5 s. Atlas Electronics offers this model on quotation.
CONDITION: 5Hz、15Hz、35Hz、50Hz can be set; PARAMETER: 5Hz、15Hz、35Hz、50Hz can be set; UNIT: 5Hz、15Hz、35Hz、50Hz can be set
Output signal
CONDITION: CAN OPEN; PARAMETER: CAN OPEN; UNIT: CAN OPEN
Power-on start time
PARAMETER: 0.5; UNIT: S
Power Supply Voltage
CONDITION: Standard; MIN: 9; TYPICAL: 12、24; MAX: 36; UNIT: V
Protection Grade
CONDITION: IP67; PARAMETER: IP67; UNIT: IP67
Resolution
PARAMETER: 0.01; UNIT: °
Sensitivity temp-coefficient
CONDITION: -40~85℃; PARAMETER: ≤100; UNIT: ppm/℃
Store temp.
MIN: -40; MAX: +85; UNIT: ℃
Weight
CONDITION: ≤220g (including 1 meter cable); PARAMETER: ≤220g (including 1 meter cable); UNIT: ≤220g (including 1 meter cable)
Working current
CONDITION: No load; TYPICAL: 40; UNIT: mA
Working Temp
MIN: -40; MAX: +85; UNIT: ℃
Zero temp. coefficient
CONDITION: -40~85℃; PARAMETER: ±0.006; UNIT: °/℃
No specification matches.
Last verification : 2026-11-03
Technical documentation
Official documents and the technical data recorded for CAN_OPEN_OUTPUT_INCLINOMETER. For a missing document or a specific revision, our experts send it to you.
CONDITION: 5Hz、15Hz、35Hz、50Hz can be set; PARAMETER: 5Hz、15Hz、35Hz、50Hz can be set; UNIT: 5Hz、15Hz、35Hz、50Hz can be set
Output signal
CONDITION: CAN OPEN; PARAMETER: CAN OPEN; UNIT: CAN OPEN
Power-on start time
PARAMETER: 0.5; UNIT: S
Power Supply Voltage
CONDITION: Standard; MIN: 9; TYPICAL: 12、24; MAX: 36; UNIT: V
Protection Grade
CONDITION: IP67; PARAMETER: IP67; UNIT: IP67
Resolution
PARAMETER: 0.01; UNIT: °
Sensitivity temp-coefficient
CONDITION: -40~85℃; PARAMETER: ≤100; UNIT: ppm/℃
Store temp.
MIN: -40; MAX: +85; UNIT: ℃
Weight
CONDITION: ≤220g (including 1 meter cable); PARAMETER: ≤220g (including 1 meter cable); UNIT: ≤220g (including 1 meter cable)
Working current
CONDITION: No load; TYPICAL: 40; UNIT: mA
Working Temp
MIN: -40; MAX: +85; UNIT: ℃
Zero temp. coefficient
CONDITION: -40~85℃; PARAMETER: ±0.006; UNIT: °/℃
Applications and use cases
Architectures in which CAN_OPEN_OUTPUT_INCLINOMETER can play a role, derived from its category. This is not a compatibility statement: check the specifications against your requirements.
Free parking spaces, lifted manhole covers and full bins are only seen during rounds. Wireless sensors on the road report occupancy, tilt and level through outdoor gateways
To check
Installation on or in the road surface
Radio range from below a vehicle or a cast-iron cover
Battery life with the expected number of events
Associated system blocks
Road sensorsGateway
Need a complete solution?
Send a request for CAN_OPEN_OUTPUT_INCLINOMETER and the other parts of your project.
Answers to the questions that the recorded characteristics of CAN_OPEN_OUTPUT_INCLINOMETER can answer. A question is not asked when nothing is recorded to answer it.
1Does it support CAN bus?
Yes — recorded under "Output rate": CONDITION: 5Hz、15Hz、35Hz、50Hz can be set; PARAMETER: 5Hz、15Hz、35Hz、50Hz can be set; UNIT: 5Hz、15Hz、35Hz、50Hz can be set.
2What input voltage does it require?
CONDITION: Standard; MIN: 9; TYPICAL: 12、24; MAX: 36; UNIT: V (source: Power Supply Voltage).
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
What is recorded about the regulatory status and the life of this part.
Regulatory compliance
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.