SOLO CO2 5000 (A2) – NDIR CO2 Sensor with Modbus RS485 and SDI-12 Waterproof Connector

NDIR CO2 Sensor with Modbus RS485 and SDI-12 Waterproof Connector

Environmental Sensor Nodes

  • -10 ~ +50 °C
  • 400~5000 ppm
  • RS-485
  • 110 * 50 * 35 mm
Manufacturer part number
101990670
Manufacturer
Seeed Studio
Operating Temperature
-10 ~ +50 °C
Range
400~5000 ppm

The SOLO CO2 5000 (A2) is an NDIR carbon dioxide concentration sensor with Modbus-RTU RS485 and SDI-12 outputs, designed for air quality monitoring indoors and outdoors.

Product overview

Seeed Studio. The SenseCAP SOLO CO2 5000 (A2) is a digital NDIR (nondispersive infrared) CO2 sensor, referenced as model SOLO CO2 5000 (A2). It measures carbon dioxide concentration in air over a range of 400 to 5000 ppm, with a resolution of 1 ppm and an accuracy of ± (50 ppm + 5 % of reading) between 400 and 3000 ppm.

Measurement and performance. Response time is less than or equal to 4 ms, the T90 response time is under 5 minutes for a 90 % step change, and the typical warm-up time is 120 s. The sensor is fully calibrated and includes a built-in calibration function. The poll rate is 1 Hz with a scan interval of 1 s.

Interfaces and communication. The sensor communicates over Modbus-RTU RS485 (default output, slave address 1) and Modbus-ASCII RS485, or over SDI-12 (v1.4) after opening the cover and setting the board buttons. The cable is 2 meters long and the waterproof aviation connector allows immediate connection to the SenseCAP Sensor Hub 4G Data Logger. Data can be uploaded to the SenseCAP Portal or to a user server via MQTT.

Power and environment. The power supply ranges from 5 V to 16 V. Typical active-mode current consumption is 55 mA at 5 V and 20 mA at 16 V, and sleep-mode consumption is 35 µA at 5 V. The sensor operates from -10 to +50 °C at 0 to 85 % humidity, non-condensing. The ingress protection rating is IPx5, the PTFE filter not being waterproof. The enclosure is PC and the device weighs 300 g.

Typical uses and integration. With its RS485 Modbus and SDI-12 outputs, this sensor connects to PLCs, data loggers and acquisition stations, for ventilation and HVAC monitoring in buildings, air quality supervision, or outdoor environmental applications.

See all specifications

Highlights

  • Response time: ≤ 4ms
  • Accuracy: ± (50ppm+5%*MV)(in 400~3000ppm)
  • Cable Length: 2 meters
  • Communication Protocol for Sensor: Modbus-RTU RS485
  • Cosine response: ≤10%(Deviation of sun height of 10° from ideal value on clear day)
  • Data Upload: SenseCAP Portal(default) User's Server (MQTT Server)

Typical applications

Derived from the part category, not a compatibility statement.

Good to know before integrating

  • Thermal: rated operating range -10 ~ +50 °C — check it against the installation environment.