S-pH-01B – Industrial pH sensor, Modbus RTU RS485 and 0-2 V analog output

Industrial pH sensor, Modbus RTU RS485 and 0-2 V analog output

Modular DIN-Rail Remote I/O Modules

  • -40℃ ~ 85℃
  • 0 ~ 14pH
  • RS-485 MODBUS-RTU
  • 35mA@24V DC
Manufacturer part number
314990622
Manufacturer
Seeed Studio
Operating Temperature
-40℃ ~ 85℃
Range
0 ~ 14pH

Seeed Studio S-pH-01B industrial pH sensor measuring 0 to 14 pH, with RS485 Modbus RTU and 0-2 V analog voltage outputs, for solutions and semi-solid substrates.

Product overview

Overview. The Seeed Studio S-pH-01B industrial pH sensor measures 0 to 14 pH with ±0.1 pH accuracy and 0.01 pH resolution. It is fully calibrated at the factory and can be used for a solution or a semi-solid substrate.

Main characteristics. The probe is 70 mm long with a 3 mm diameter, fitted with 3/4" NPT screw threads; the transmitter measures 140 mm × 65 mm × 50 mm. Temperature measurement covers -40 to 80 °C with 0.1 °C resolution and ±0.5 °C accuracy. The pH input is high impedance and isolated.

Interfaces and connectivity. The signal is available as RS-485 Modbus RTU and as 0-2 V analog voltage (output resistance about 0 ohm). The electrode cable is 5 m long and the power and signal cable 2 m, the latter being customizable. Start-up time is under 2 seconds.

Power and environment. The sensor operates from a 3.9 to 30 V DC supply, drawing 35 mA at 24 V DC. The electrode is IP68 and the transmitter IP65. The enclosure is PC, with an operating temperature of -40 to 85 °C and 0 to 100 %RH humidity (non-condensing). A red LED shows the equipment status.

Typical uses. With its RS485 Modbus RTU output, the sensor can be connected to a PLC or a Modbus gateway to monitor pH in water and soil. For calibration integration, the manufacturer's Modbus documentation describes the corresponding commands.

See all specifications

Highlights

  • Accuracy: ± 0.1 pH
  • Communication Protocol for Sensor: Modbus-RTU RS485
  • Cosine response: ≤10%(Deviation of sun height of 10° from ideal value on clear day)
  • Data Upload: SenseCAP Portal(default) User's Server (MQTT Server)
  • Device weight: 1600g
  • Device Weight(NW): 876g

Typical applications

Derived from the part category, not a compatibility statement.

Good to know before integrating

  • Thermal: rated operating range -40℃ ~ 85℃ — check it against the installation environment.

Technical questions

Ask a question

No published question about this part yet. Questions are reviewed before publication.

Request a quote