The Seeed Studio S-PAR-02A is an industrial photosynthetically active radiation (PAR) sensor measuring 400 to 700 nm. It monitors light in environments with natural light sources, with RS485 digital output.
Operating Temperature-30 ~ +75 ℃
Measuring Range0 ~ 2500 μmol/m²·s
InterfaceRS-485
Supply voltage5V ~24V
Accuracy±0.1 ℃
Measurement Accuracy±2%
Product overview
Overview. The Seeed Studio industrial PAR sensor S-PAR-02A is a photosynthetically active radiation (PAR) sensor that measures in real time the radiation from 400 to 700 nm in environments with natural light sources. It generates a voltage signal directly proportional to the PAR under the light source, expressed in μmol/m²·s.
Main characteristics. Measuring range 0 to 2500 μmol/m²·s, resolution 1 μmol/m²·s, measurement accuracy ±2%, linearity with maximum deviation 1%, yearly stability offset and response time 10 μs. Cosine response is 10% or less for a 10° deviation of sun height on a clear day. The probe measures 70 mm in length and 3 mm in diameter, and the PC enclosure is rated IP66.
Interfaces and connectivity. The sensor communicates over the MODBUS-RTU RS485 protocol, with a 2 m cable. A 0-2.5 V analog voltage output can be customised. It connects directly to RS485 data loggers or digital voltmeters, and is compatible with the SenseCAP LoRaWAN® Data Logger for transmission over a LoRaWAN® network.
Power and environment. Supply voltage 5 V to 24 V, sensor power supply 5 V/12 V depending on sensor type. Operating temperature -30 to +75 ℃, operating humidity 0 to 100 %RH non-condensing.
Typical uses. Light monitoring for research and agriculture, to control parameters that affect plant photosynthesis. The sensor can feed custom monitoring systems connected to a PLC or a Modbus data logger.
Technical data and information compiled from the Seeed Studio catalogue; quotations available from Atlas Electronics.
The Seeed Studio S-PAR-02A is an industrial photosynthetically active radiation (PAR) sensor measuring 400 to 700 nm. It monitors light in environments with natural light sources, with RS485 digital output.
Operating Temperature-30 ~ +75 ℃
Measuring Range0 ~ 2500 μmol/m²·s
InterfaceRS-485
Supply voltage5V ~24V
Accuracy±0.1 ℃
2. Datasheet extract (recorded values)
Parameter
Value
IP rating
IP66
Supply voltage
5V ~24V
Response time
10 μs
Accuracy
±0.1 ℃
Cable Length
2m
Communication Protocol for Sensor
Modbus-RTU RS485
Cosine response
≤10%(Deviation of sun height of 10° from ideal value on clear day)
Data Upload
SenseCAP Portal(default) User's Server (MQTT Server)
Device weight
1600g
Device Weight(NW)
876g
ECTDS Sensor
Water Electrical Conductivity, Total Dissolved Solids
Switching power supply Red LED indicates equipment status
Wall Power
DC 12V/2A
Integration
Points to check before using 314990733 in a design. They are derived from the recorded characteristics, not from the manufacturer's application circuits.
1Powerplan for a supply compatible with 5V ~24V.
2Thermalrated operating range -30 ~ +75 ℃ — check it against the installation environment.
Power and communication
Supply voltage
5V ~24V
Power Supply for Sensor
5V/12V (depending on sensor types)
Solar Power (optional)
Maximum power: 12wp size: 340*255mm
Wall Power
DC 12V/2A
Check the exact pin assignment and the application circuit in the datasheet, or ask our experts.
Implementation checklist
Power : plan for a supply compatible with 5V ~24V.
Thermal : rated operating range -30 ~ +75 ℃ — check it against the installation environment.
Applications and use cases
Architectures in which 314990733 can play a role, derived from its category. This is not a compatibility statement: check the specifications against your requirements.
A proprietary PLC locks the project into one vendor’s tools. Industrial controllers built on the Raspberry Pi Compute Module run Linux, Node-RED, Python or CODESYS on DIN rail, with I/O modules, an operator panel and a cellular router for remote access
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
Industrial pH Sensor MODBUS-RTU RS485 & 0-2V Analog Voltage (S-pH-01B), with waterproof aviation connector
A
Yes, the device is fully calibrated prior to shipment from the factory.; About calibration, please refer to the document :; https://raw.githubusercontent.com/Jenkinlu001/SenseCAP/master/PH10-AppNote-PH%20Calibration%20by%20Modbus%20Command.doc
Accuracy
± 0.1 pH
Cable Length
Power and Signal Cable:2 meters (Customizable); Electrode Cable: 5 meters