The Sfere S3I96Y digital power meter measures single-phase or three-phase current in power distribution systems. It directly replaces an analog pointer ammeter.
Operating Temperature-40℃~70℃(LED),-25℃~70℃(LCD)
Safe Power Supply — RangeAC 80~270V 50/60Hz,DC 100~350V
Input VoltageRated value:AC 100V,220V,400V etc
Input CurrentRated value:AC 1A,5A
Safe Power Supply — Consumption≤5VA
Input Frequency45~65Hz
Product overview
Overview. The Sfere S3I96Y is a digital power meter with LED display for measuring single-phase or three-phase current parameters in power distribution systems. Programmable, it offers different mounting dimensions and can directly replace an analog pointer ammeter.
Main characteristics. Accuracy of 0.5% by default, or 0.2% depending on the version. Rated input current AC 1A or 5A, with continuous overload of 2 times the rated value. Rated input voltage AC 100V, 220V, 400V etc., input frequency 45 to 65 Hz. Data update rate 1 s.
Interfaces and connectivity. RS485 communication port, 2-wire, Modbus-RTU protocol, up to 9600 bps. Two dry contact digital inputs, isolated at 2 kVAC, and two relay outputs, contacts rated AC 5A/250V or DC 5A/30V, isolated at 2 kVAC. Analog output dc 4~20mA (load ≤350Ω) or DC 0~5V (load ≥20kΩ).
Power and environment. Safe power supply range AC 80~270V 50/60Hz or DC 100~350V, consumption ≤5VA. Insulation ≥2kVAC. Degree of protection IP64 at the front, IP20 at the rear. Operating temperature -40℃ to 70℃ (LED), -25℃ to 70℃ (LCD). Relative humidity ≤93%RH. Altitude ≤2500m.
Typical uses. Power monitoring in power monitoring and power measuring devices, advanced manufacturing smart equipment and smart buildings. The Modbus-RTU link allows integration into a supervision system or a PLC.
The Sfere S3I96Y digital power meter measures single-phase or three-phase current in power distribution systems. It directly replaces an analog pointer ammeter.
Operating Temperature-40℃~70℃(LED),-25℃~70℃(LCD)
Safe Power Supply — RangeAC 80~270V 50/60Hz,DC 100~350V
Input VoltageRated value:AC 100V,220V,400V etc
Input CurrentRated value:AC 1A,5A
Safe Power Supply — Consumption≤5VA
2. Datasheet extract (recorded values)
Parameter
Value
Accuracy
0.5%(default),0.2%
Altitude
≤2500m
Analog Output
dc 4~20mA,load ≤350Ω DC 0~5V,load≥20kΩ
Communication port
RS485,Modbus-RTU,2-WIRE,up tp 9600bps
Corresponding field:
power monitoring device power measuring device advanced manufacturing smart equipment smart building
Data Update Rate
1s
Degree of protection
Front:IP64,Rear :IP20
Digital Input
2 dry contact inputs,Isolation:2kVAC
Input Current
Rated value:AC 1A,5A
Input Frequency
45~65Hz
Input — Overload
Continuous:2 times of rated value
Input Voltage
Rated value:AC 100V,220V,400V etc
Insulation
≥2kVAC
Operating Temperature
-40℃~70℃(LED),-25℃~70℃(LCD)
Relative humidity
≤93%RH
Relay Output
2 relay outputs,contact rated at AC 5A/250V or DC 5A/30V,Isolation:2kVAC
Safe Power Supply — Consumption
≤5VA
Safe Power Supply — Range
AC 80~270V 50/60Hz,DC 100~350V
Storage Temperature
-45℃~85℃(LED),-30℃~80℃(LCD)
The Product Name:
S3I96Y Digital power meter
The Product Type:
Digital Power Meter
Integration
Points to check before using S3I96Y in a design. They are derived from the recorded characteristics, not from the manufacturer's application circuits.
1Thermalrated operating range -40℃~70℃(LED),-25℃~70℃(LCD) — check it against the installation environment.
Power and communication
Input Current
Rated value:AC 1A,5A
Input Voltage
Rated value:AC 100V,220V,400V etc
Safe Power Supply — Consumption
≤5VA
Safe Power Supply — Range
AC 80~270V 50/60Hz,DC 100~350V
Check the exact pin assignment and the application circuit in the datasheet, or ask our experts.
Implementation checklist
Thermal : rated operating range -40℃~70℃(LED),-25℃~70℃(LCD) — check it against the installation environment.
Applications and use cases
Architectures in which S3I96Y can play a role, derived from its category. This is not a compatibility statement: check the specifications against your requirements.
Energy bills give one total for the whole site. Submetering places meters and current sensors on each circuit or usage and collects their readings through a gateway, so consumption can be followed per building, floor or machine
To check
Number of circuits and phases to meter, and the current range of each
Wired Modbus bus or wireless LoRaWAN, depending on cabling access in the switchboards
Accuracy class required for internal allocation or for billing
A building’s energy, comfort and occupancy data sit in separate systems. Sensors, meters and gateways feed one model of the building, room by room, to compare scenarios and steer the installations
To check
Data model and building plans available
Software platform hosting the twin
Sensor density needed for a useful model
Associated system blocks
SensorsMetersGateways
Need a complete solution?
Send a request for S3I96Y and the other parts of your project.
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
Current productSfere
S3I96Y
Digital power meter for single-phase and three-phase systems
What is recorded about the regulatory status and the life of this part.
Regulatory compliance
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
With your consent, we use Google cookies to measure the site’s audience and our advertising. Your quote basket and comparison stay in your browser either way. Details