SI-3108
Stainless Steel Electromagnetic Flow Meter with 4-20 mA Output

- Accuracy
- ±0.5%
- Communication
- RS485, GPRS, HART
- Diameter
- DN6~DN2200mm
- Explosion-proof
- No
Stainless Steel Electromagnetic Flow Meter with 4-20 mA Output
Sino-Inst SI-3108 electromagnetic flow meter for measuring the volumetric flow of conductive liquids, including corrosive ones, with ±0.5% accuracy.
Overview. The Sino-Inst SI-3108 is an electromagnetic flow meter based on Faraday's induction principle, designed to measure the volumetric flow of conductive liquids, including acids, alkalis, salts and liquid-solid suspensions such as sludges and pulps.
Main characteristics. Accuracy of ±0.5%, diameters from DN6 to DN2200 mm, flow velocity range of 0.3 to 10 m/s, nominal pressure GB 0.6 MPa for DN700 to DN2200. The body is carbon steel as standard, stainless steel as an option, with carbon steel flange as standard or stainless steel flange as an option. It has no obstruction component and therefore no pressure loss. Measurement is unaffected by fluid density and viscosity, with temperature compensation required. Bidirectional flow measurement is supported.
Electrodes and lining. Electrodes are available in Hastelloy B, Hastelloy C, titanium, tantalum and platinum. Available linings are PFA (-40 to 160 °C), PTFE (-20 to 120 °C), FEP (-40 to 160 °C), natural rubber, polyurethane rubber, silicone rubber, and rubber suited to slurries and paper pulp. The choice depends on the fluid and the diameter range.
Connectivity and power. Standard outputs are 4-20 mA and pulse/frequency, with RS485 (Modbus) or HART protocol as options. Power supply is 220 VAC, 24 VDC or lithium battery, the battery version having no signal output. Power consumption below 20 W.
Environment. Protection rating IP65 (compact type), IP67 or IP68 (remote type). Ambient temperature -20 to +60 °C, humidity 5 to 90%. Fluid temperature below 60 °C. The meter is not explosion-proof.
Typical uses. Measurement of corrosive acid, alkali or saline liquids in the chemical industry, as well as tap water, industrial water, seawater and effluents. The RS485 Modbus output allows connection to a PLC or supervision system.
Installation. Observe a minimum straight run of 5 DN upstream and 3 DN downstream.
No published question about this part yet. Questions are reviewed before publication.
Every characteristic recorded for SI-3108, with where it comes from. Use the filters to find one quickly.
| Characteristic | Value |
|---|---|
| Accuracy | ±0.5% |
| Body Material | Carbon steel (standard),Stainless steel(optional) |
| Communication | RS485, GPRS, HART |
| Diameter | DN6~DN2200mm |
| Electrode | HastalloyB(HB),HastalloyC(HC),Titanium(Ti),Tantalum(Ta),Platinum(Pt), |
| Explosion-proof | No |
| Flow rate | 0.3~10m/s |
| Fluoroplastic — PFA — -40~160℃ — Corrosive acid-base salt liquid | DN10~DN300 |
| Fluoroplastic — PTFE(F4) — -20~120℃ — Corrosive acid-base salt liquid | DN10~DN1600 |
| Fluoroplastic — Teflon F46(FEP) — -40~160℃ — Corrosive acid-base salt liquid | DN10~DN200 |
| Hastelloy B (HB) | 1. Salt solution (chloride, sodium salt, potassium salt, ammonium salt, seawater, etc.)2. Alkaline solution (such as concentration less than 50% potassium hydroxide solution) |
| Hastelloy C (HC) | Oxidizing salt solution (Fe+++, Cu++, seawater) |
| Installation Way | Carbon steel flange (standard), Stainless steel flange(optional) |
| Lining material — Linner — Temperature — Suitable medium | Tap water, industrial water,seawater |
| Material | Medium |
| Medium | Acid, alkali, salt and other corrosive medium in chemical industry |
| Medium temperature | <60℃ |
| NOMINAL PRESSURE | GB 0.6MPa (DN700~DN2200) |
| Optional | RS485 (Modbus), HART protocol |
| Platinum (Pt) | Acid, alkali, salt solution |
| Power | <20W |
| Power supply | 220VAC/24VDC/lithium battery |
| Protection proof | IP65(compact type),IP67,IP68(suitable for remote type) |
| Rubber — Natural Rubber(NR) — -20~60℃ — Tap water, industrial water, seawater | DN65~DN1600 |
| Rubber — Polyurethane Rubber(PU) — -20~60℃ — Slurry, paper pulp etc. | DN25~DN500 |
| Rubber — Silicone rubber — -20~180℃ — Water | DN40~DN1600 |
| Rubber — Slurry, paper pulp, etc. — -20~60℃ — Tap water, industrial water, seawater | DN65~DN1600 |
| Signal Output | Pulse and 4~20mA; (if use lithium battery, without signal output) |
| Standard | 4-20mA + Pulse/Frequency |
| Straight pipe required | Upstream ≥5DN,downstream ≥3DN |
| Tantalum(Ta) | 1. Hydrochloric acid, sulfuric acid, oxidizing acid, aqua regia 2. Chlorine dioxide, ferric chloride, hypochlorous acid, sodium cyanide, lead acetate, etc. |
| Titanium (Ti) | 1. Salt solution (chloride, sodium salt, potassium salt, ammonium salt, seawater, etc.); 2. Alkaline solution (such as a concentration less than 50% potassium hydroxide solution) |
| Tungsten carbide (WC) | Handled neutral industrial sewage and domestic sewage. Resistant to solid particle interference |
| Work Environment | Ambient temperature:-20~+60℃,Ambient humidity:5%~90% |
No specification matches.
Last verification : 2026-11-02
Official documents and the technical data recorded for SI-3108. For a missing document or a specific revision, our experts send it to you.
Sino-Inst SI-3108 electromagnetic flow meter for measuring the volumetric flow of conductive liquids, including corrosive ones, with ±0.5% accuracy.
| Parameter | Value |
|---|---|
| Accuracy | ±0.5% |
| Body Material | Carbon steel (standard),Stainless steel(optional) |
| Communication | RS485, GPRS, HART |
| Diameter | DN6~DN2200mm |
| Electrode | HastalloyB(HB),HastalloyC(HC),Titanium(Ti),Tantalum(Ta),Platinum(Pt), |
| Explosion-proof | No |
| Flow rate | 0.3~10m/s |
| Fluoroplastic — PFA — -40~160℃ — Corrosive acid-base salt liquid | DN10~DN300 |
| Fluoroplastic — PTFE(F4) — -20~120℃ — Corrosive acid-base salt liquid | DN10~DN1600 |
| Fluoroplastic — Teflon F46(FEP) — -40~160℃ — Corrosive acid-base salt liquid | DN10~DN200 |
| Hastelloy B (HB) | 1. Salt solution (chloride, sodium salt, potassium salt, ammonium salt, seawater, etc.)2. Alkaline solution (such as concentration less than 50% potassium hydroxide solution) |
| Hastelloy C (HC) | Oxidizing salt solution (Fe+++, Cu++, seawater) |
| Installation Way | Carbon steel flange (standard), Stainless steel flange(optional) |
| Lining material — Linner — Temperature — Suitable medium | Tap water, industrial water,seawater |
| Material | Medium |
| Medium | Acid, alkali, salt and other corrosive medium in chemical industry |
| Medium temperature | <60℃ |
| NOMINAL PRESSURE | GB 0.6MPa (DN700~DN2200) |
| Optional | RS485 (Modbus), HART protocol |
| Platinum (Pt) | Acid, alkali, salt solution |
| Power | <20W |
| Power supply | 220VAC/24VDC/lithium battery |
| Protection proof | IP65(compact type),IP67,IP68(suitable for remote type) |
| Rubber — Natural Rubber(NR) — -20~60℃ — Tap water, industrial water, seawater | DN65~DN1600 |
| Rubber — Polyurethane Rubber(PU) — -20~60℃ — Slurry, paper pulp etc. | DN25~DN500 |
| Rubber — Silicone rubber — -20~180℃ — Water | DN40~DN1600 |
| Rubber — Slurry, paper pulp, etc. — -20~60℃ — Tap water, industrial water, seawater | DN65~DN1600 |
| Signal Output | Pulse and 4~20mA; (if use lithium battery, without signal output) |
| Standard | 4-20mA + Pulse/Frequency |
| Straight pipe required | Upstream ≥5DN,downstream ≥3DN |
| Tantalum(Ta) | 1. Hydrochloric acid, sulfuric acid, oxidizing acid, aqua regia 2. Chlorine dioxide, ferric chloride, hypochlorous acid, sodium cyanide, lead acetate, etc. |
| Titanium (Ti) | 1. Salt solution (chloride, sodium salt, potassium salt, ammonium salt, seawater, etc.); 2. Alkaline solution (such as a concentration less than 50% potassium hydroxide solution) |
| Tungsten carbide (WC) | Handled neutral industrial sewage and domestic sewage. Resistant to solid particle interference |
| Work Environment | Ambient temperature:-20~+60℃,Ambient humidity:5%~90% |
Answers to the questions that the recorded characteristics of SI-3108 can answer. A question is not asked when nothing is recorded to answer it.
Yes — recorded under "Communication": RS485, GPRS, HART.
Yes — recorded under "Optional": RS485 (Modbus), HART protocol.
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
Stainless Steel Electromagnetic Flow Meter with 4-20 mA Output

Large-Size Electromagnetic Flow Meter for Large Pipes

Remote Water Flow Meter

FMC240 Electromagnetic Flowmeter Measuring Tap Water

Describe your application and constraints in a request.
What is recorded about the regulatory status and the life of this part.
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
| Current status | Status not stated |
| Key dates | Not recorded |
| Manufacturer part number | SI-3108 |
| Manufacturer | Sino-Inst |
Electromagnetic Flow Meters
Insertion Electromagnetic Flowmeter
Price on request
Electromagnetic Flow Meters
Intelligent Electromagnetic Flowmeter DN10 to DN2000 · Ref. : AF-EMF89
Price on request
Electromagnetic Flow Meters
DN25 to DN400 Electromagnetic Heat Flowmeter · Ref. : MFE600H
Price on request
Electromagnetic Flow Meters
Electromagnetic flow meter
Price on request
With your consent, we use Google cookies to measure the site’s audience and our advertising. Your quote basket and comparison stay in your browser either way. Details