- Reynolds Number Range
- 2×10⁵ ≤ Re_D ≤ 2×10⁶
- Temp. Range
- -50℃~+600℃
- Accuracy
- ±0.5%-1.5%
- Accuracy Class
- 0.5, 1, 1.5, 2
Venturi Tube Flow Meter for Liquids, Gas and Steam
The SI-3704 is a differential pressure Venturi tube flow meter for measuring the flow of liquids, gas and steam, from DN8 to DN3000, compliant with GB/T 2624-2006 and ASME PTC 19.5-2004.
Sino-Inst SI-3704. The SI-3704 Venturi Tube Flow Meter from Sino-Inst is a Venturi tube flow meter, a standard throttling device for flow measurement in closed pipes. Main characteristics — The principle relies on the Venturi effect: the contraction of the section creates a pressure difference proportional to the flow, calculated from the continuity equation and Bernoulli's equation. Accuracy class is 0.5, 1, 1.5 or 2, with an uncertainty of ±0.5% to ±1.5% and a Reynolds number between 2×10⁵ and 2×10⁶. The throttle diameter ratio β lies between 0.3 and 0.75. Connections and dimensions — Available connections are flange, butt welding and thread. Nominal diameter ranges from DN8 to DN3000, with a machined convergent section for 8 mm ≤ DN ≤ 250 mm, a rough cast convergent section for 100 mm ≤ DN ≤ 1600 mm and a rough welded steel plate convergent section for 100 mm ≤ DN ≤ 3000 mm. Operating conditions — The medium can be gas, water, chemicals, crude, slurry or high-temperature steam. Medium temperature ranges from -50 °C to 600 °C, and working pressure is PN ≤ 42 MPa. Typical uses — This flow meter suits flow measurement on large-diameter pipes and on loaded fluids, particularly in processes requiring low permanent pressure loss. It requires shorter upstream and downstream straight pipe sections than other differential pressure devices and does not need individual calibration under JJG 640-94. Integration — The SI-3704 is supplied with uncertainty column A (zero additional uncertainty) or column B (0.5% additional uncertainty). Available on quotation from Atlas Electronics.
No published question about this part yet. Questions are reviewed before publication.
Every characteristic recorded for SI-3704, with where it comes from. Use the filters to find one quickly.
| Characteristic | Value |
|---|---|
| Accuracy | ±0.5%-1.5% |
| Accuracy Class | 0.5, 1, 1.5, 2 |
| Column A | Zero additional uncertainty values |
| Column B | 0.5% additional uncertainty values |
| Connection | Flange connection, Butt welding, Thread |
| Connection Type | Flange, Welding, Threaded |
| Diameter | DN8~DN3000 |
| — Machined convergent section | 8 mm ≤ DN ≤ 250 mm |
| Medium | Gas, water, Chemical, Crude, Slurry to even high temperature Steam |
| Medium temperature | -50 °C ≤ t ≤ 600 °C |
| Nominal diameter | 8 mm ≤ DN ≤ 3000 mm |
| Pressure | ≤42MPa |
| Reference Standards | GB/T 2624-2006, JJG 640-94, ASME PTC 19.5-2004 |
| Reynolds Number Range | 2×10⁵ ≤ Re_D ≤ 2×10⁶ |
| — Rough cast convergent section | 100 mm ≤ DN ≤ 1600 mm |
| — Rough welded steel plate convergent section | 100 mm ≤ DN ≤ 3000 mm |
| Temp. Range | -50℃~+600℃ |
| Throttle Diameter Ratio (β) | 0.3 ≤ β ≤ 0.75 |
| Working Pressure | PN ≤ 42 MPa |
No specification matches.
Last verification : 2026-11-02
Official documents and the technical data recorded for SI-3704. For a missing document or a specific revision, our experts send it to you.
The SI-3704 is a differential pressure Venturi tube flow meter for measuring the flow of liquids, gas and steam, from DN8 to DN3000, compliant with GB/T 2624-2006 and ASME PTC 19.5-2004.
| Parameter | Value |
|---|---|
| Accuracy | ±0.5%-1.5% |
| Accuracy Class | 0.5, 1, 1.5, 2 |
| Column A | Zero additional uncertainty values |
| Column B | 0.5% additional uncertainty values |
| Connection | Flange connection, Butt welding, Thread |
| Connection Type | Flange, Welding, Threaded |
| Diameter | DN8~DN3000 |
| — Machined convergent section | 8 mm ≤ DN ≤ 250 mm |
| Medium | Gas, water, Chemical, Crude, Slurry to even high temperature Steam |
| Medium temperature | -50 °C ≤ t ≤ 600 °C |
| Nominal diameter | 8 mm ≤ DN ≤ 3000 mm |
| Pressure | ≤42MPa |
| Reference Standards | GB/T 2624-2006, JJG 640-94, ASME PTC 19.5-2004 |
| Reynolds Number Range | 2×10⁵ ≤ Re_D ≤ 2×10⁶ |
| — Rough cast convergent section | 100 mm ≤ DN ≤ 1600 mm |
| — Rough welded steel plate convergent section | 100 mm ≤ DN ≤ 3000 mm |
| Temp. Range | -50℃~+600℃ |
| Throttle Diameter Ratio (β) | 0.3 ≤ β ≤ 0.75 |
| Working Pressure | PN ≤ 42 MPa |
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
Venturi Tube Flow Meter for Liquids, Gas and Steam

3051 Differential Pressure Sensor 12VDC Measuring Liquid Gas Air

Differential Pressure Insert Venturi Flow Meter 2.5MPa DN500 - DN2600

Pipe Type Differential pressure online density meter

Describe your application and constraints in a request.
What is recorded about the regulatory status and the life of this part.
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
| Current status | Status not stated |
| Key dates | Not recorded |
| Manufacturer part number | SI-3704 |
| Manufacturer | Sino-Inst |
Differential Pressure Sensors
Piezoresistive oil-filled differential pressure sensor · Ref. : MDM290
Price on request
Differential Pressure Sensors
Air differential pressure sensor with RS485 Modbus RTU output
Price on request
Differential Pressure Sensors
Differential Pressure Sensor I2C ±500 Pa · Ref. : SEN0343
Price on request
Differential Pressure Sensors
Averaging Pitot Tube Flow Meter, Insertion Type · Ref. : SI-3703
Price on request
With your consent, we use Google cookies to measure the site’s audience and our advertising. Your quote basket and comparison stay in your browser either way. Details