SI-3705 – V-Cone differential pressure flow meter

V-Cone differential pressure flow meter

Differential Pressure Sensors

  • -200 °C ~ 700 °C
  • 8 × 10^3 ~ 5 × 10^6
  • 4 ~ 20mA
  • Class 0.5
Manufacturer part number
SI-3705
Manufacturer
Sino-Inst
Operating Temperature
-200 °C ~ 700 °C
Reynolds Number Range
8 × 10^3 ~ 5 × 10^6

The SI-3705 is a V-Cone differential pressure flow meter measuring liquids, gas and steam, with Class 0.5 accuracy and a 10:1 range ratio.

Product overview

Overview. The Sino-Inst SI-3705 is a V-Cone flow meter based on the differential pressure principle, designed to measure the flow of liquids, gas (including natural gas) and steam. Its center cone prevents a sharp contraction of the fluid in the pipeline, producing a more stable differential pressure signal.

Main characteristics. Accuracy Class 0.5, with available classes of ±0.5%, ±1.5% and ±2.5%. Repeatability of ±0.1% and long-term stability of ±0.1% F.S per year. Range ratio 10:1. Nominal diameters from DN15 to DN2000 (1/2″ to 120″), and Reynolds number range from 8 × 10^3 to 5 × 10^6. Connection types: flange, welded or clamped.

Interfaces and connectivity. Differential pressure transmitter with 4 to 20 mA output, with RS485 or HART communication. Intelligent flow totalizer with 4 to 20 mA output.

Power and environment. Transmitter powered at 24 VDC and totalizer at 220 VDC. Operating pressure up to 42 MPa depending on the version (2.5 to 42 MPa), operating temperature from -200 °C to 700 °C and ambient temperature up to 80 °C. Relative humidity from 5 to 85%.

Typical uses. Flow measurement on dirty or high-viscosity media under harsh conditions. The RS485 connection or HART output allows integration into a supervisory system.

Integration. Short straight pipe requirements: 0 to 3 D upstream and 0 to 1 D downstream. Reduced pressure loss thanks to the cone geometry.

See all specifications

Highlights

  • Accuracy: Class 0.5
  • Accuracy Class: ±0.5%, ±1.5%, ±2.5%
  • Communication mode of DP transmitter:: RS485/ HART
  • Communication mode of the DP transmitter:: 4mA ~ 20mA
  • Current of intelligent flow totalizer:: 4 ~ 20mA
  • Current of the DP transmitter :: 4 ~ 20mA

Good to know before integrating

  • Thermal: rated operating range -200 °C ~ 700 °C — check it against the installation environment.