C2S-CB-24B-C02 – CC-Link IE Field Basic valve terminal for 24 double solenoid valves

CC-Link IE Field Basic valve terminal for 24 double solenoid valves

Pneumatic Valves and Manifolds

  • -5~+50℃
  • M12
  • Supported
  • 30mA
Manufacturer part number
C2S-CB-24B-C02
Manufacturer
Solidot
Operating Temperature
-5~+50℃
Fieldbus Interface
M12

The Solidot C2S-CB-24B-C02 is a CC-Link IE Field Basic valve terminal driving 24 CKD-4GD2 / 4RD2 double solenoid valves, on a fully integrated all-aluminum alloy base.

Product overview

Overview. The Solidot C2S-CB-24B-C02 is a CC-Link IE Field Basic valve terminal for controlling 24 double solenoid valves of the CKD-4GD2 / 4RD2 series. Its customized base plate has a fully integrated all-aluminum alloy design.

Main characteristics. Modular structure that occupies little space, dimensions of 346.5 × 90 × 65 mm, and weight varying by product model. The channels provide open circuit and short circuit diagnostics, as well as short circuit protection.

Interfaces and connectivity. The fieldbus uses two 4-pin D-code female M12 connectors, with support for cascading communication. The protocol is CC-Link IE Field Basic, with a transmission rate of 100 Mb/s and a transmission distance of 100 m or less. The transmission medium is UTP or STP Category 5 or higher cable, with STP recommended. Remote diagnosis reduces troubleshooting difficulties.

Power and environment. Power supply is 18 to 36 VDC through a 5-pin A-coded male M12 connector, with electrical isolation, reverse polarity protection and power interface surge protection. Rated current consumption is 30 mA. The product has an IP20 protection rating, an operating temperature of -5 to +50 ℃, a storage temperature of -20 to +75 ℃ and a relative humidity of 95 % without condensation.

Typical uses and integration. The terminal connects to a CC-Link IE Field Basic network to drive a set of CKD-4GD2 / 4RD2 solenoid valves. Its modular design and M12 connectors simplify wiring, quick installation and maintenance.

See all specifications

Highlights

  • Dimensions: 346.5*90*65mm
  • Bus connection method: 2 x M12, 4-pin, D-code, female connector (socket)
  • Bus Protocol: CC-Link IE Field Basic
  • Channel Open Circuit Diagnostics: Supported
  • Channel short circuit diagnostics: Supported
  • Channel short circuit protection: Supported

Good to know before integrating

  • Thermal: rated operating range -5~+50℃ — check it against the installation environment.

See also

Technical questions

Ask a question

No published question about this part yet. Questions are reviewed before publication.