C2S-CB-24B-C02
CC-Link IE Field Basic valve terminal for 24 double solenoid valves

- Operating Temperature
- -5~+50℃
- Fieldbus Interface
- M12
- Power interface surge protection
- Supported
- Rated current consumption
- 30mA
CC-Link IE Field Basic valve terminal for 24 double solenoid valves
Pneumatic Valves and Manifolds
The Solidot C2S-CB-24B-C02 is a CC-Link IE Field Basic valve terminal driving 24 CKD-4GD2 / 4RD2 double solenoid valves, on a fully integrated all-aluminum alloy base.
Overview. The Solidot C2S-CB-24B-C02 is a CC-Link IE Field Basic valve terminal for controlling 24 double solenoid valves of the CKD-4GD2 / 4RD2 series. Its customized base plate has a fully integrated all-aluminum alloy design.
Main characteristics. Modular structure that occupies little space, dimensions of 346.5 × 90 × 65 mm, and weight varying by product model. The channels provide open circuit and short circuit diagnostics, as well as short circuit protection.
Interfaces and connectivity. The fieldbus uses two 4-pin D-code female M12 connectors, with support for cascading communication. The protocol is CC-Link IE Field Basic, with a transmission rate of 100 Mb/s and a transmission distance of 100 m or less. The transmission medium is UTP or STP Category 5 or higher cable, with STP recommended. Remote diagnosis reduces troubleshooting difficulties.
Power and environment. Power supply is 18 to 36 VDC through a 5-pin A-coded male M12 connector, with electrical isolation, reverse polarity protection and power interface surge protection. Rated current consumption is 30 mA. The product has an IP20 protection rating, an operating temperature of -5 to +50 ℃, a storage temperature of -20 to +75 ℃ and a relative humidity of 95 % without condensation.
Typical uses and integration. The terminal connects to a CC-Link IE Field Basic network to drive a set of CKD-4GD2 / 4RD2 solenoid valves. Its modular design and M12 connectors simplify wiring, quick installation and maintenance.
No published question about this part yet. Questions are reviewed before publication.
Every characteristic recorded for C2S-CB-24B-C02, with where it comes from. Use the filters to find one quickly.
| Characteristic | Value |
|---|---|
| Dimensions | 346.5*90*65mm |
| Bus connection method | 2 x M12, 4-pin, D-code, female connector (socket) |
| Bus Protocol | CC-Link IE Field Basic |
| Channel Open Circuit Diagnostics | Supported |
| Channel short circuit diagnostics | Supported |
| Channel short circuit protection | Supported |
| Data transmission medium | UTP or STP of Category 5 or higher (STP recommended) |
| Electrical isolation | Yes |
| Fieldbus Interface | M12 |
| Operating Temperature | -5~+50℃ |
| Power Connection Method | M12 5-pin A-coded, male connector (pin) |
| Power interface surge protection | Supported |
| Power supply | 18~36 VDC |
| Protection rating | IP20 |
| Rated current consumption | 30mA |
| Relative humidity | 95 %, no condensation |
| Reverse Polarity Protection | Supported |
| Solenoid valve model | CKD-4GD2 / 4RD2 |
| Storage Temperature | -20~+75℃ |
| Transmission Distance | ≤ 100m |
| Transmission Rate | 100Mb/s |
| Weight | Varies by product model |
No specification matches.
Last verification : 2026-11-03
Official documents and the technical data recorded for C2S-CB-24B-C02. For a missing document or a specific revision, our experts send it to you.
The Solidot C2S-CB-24B-C02 is a CC-Link IE Field Basic valve terminal driving 24 CKD-4GD2 / 4RD2 double solenoid valves, on a fully integrated all-aluminum alloy base.
| Parameter | Value |
|---|---|
| Dimensions | 346.5*90*65mm |
| Bus connection method | 2 x M12, 4-pin, D-code, female connector (socket) |
| Bus Protocol | CC-Link IE Field Basic |
| Channel Open Circuit Diagnostics | Supported |
| Channel short circuit diagnostics | Supported |
| Channel short circuit protection | Supported |
| Data transmission medium | UTP or STP of Category 5 or higher (STP recommended) |
| Electrical isolation | Yes |
| Fieldbus Interface | M12 |
| Operating Temperature | -5~+50℃ |
| Power Connection Method | M12 5-pin A-coded, male connector (pin) |
| Power interface surge protection | Supported |
| Power supply | 18~36 VDC |
| Protection rating | IP20 |
| Rated current consumption | 30mA |
| Relative humidity | 95 %, no condensation |
| Reverse Polarity Protection | Supported |
| Solenoid valve model | CKD-4GD2 / 4RD2 |
| Storage Temperature | -20~+75℃ |
| Transmission Distance | ≤ 100m |
| Transmission Rate | 100Mb/s |
| Weight | Varies by product model |
Points to check before using C2S-CB-24B-C02 in a design. They are derived from the recorded characteristics, not from the manufacturer's application circuits.
| Power Connection Method | M12 5-pin A-coded, male connector (pin) |
| Power interface surge protection | Supported |
| Power supply | 18~36 VDC |
| Rated current consumption | 30mA |
Check the exact pin assignment and the application circuit in the datasheet, or ask our experts.
Answers to the questions that the recorded characteristics of C2S-CB-24B-C02 can answer. A question is not asked when nothing is recorded to answer it.
-5~+50℃ (source: Operating Temperature).
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
CC-Link IE Field Basic valve terminal for 24 double solenoid valves




Describe your application and constraints in a request.
What is recorded about the regulatory status and the life of this part.
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
| Current status | Status not stated |
| Key dates | Not recorded |
| Manufacturer part number | C2S-CB-24B-C02 |
| Manufacturer | Solidot |
Pneumatic Valves and Manifolds
CC-Link pneumatic valve terminal with 24 solenoid valves · Ref. : C2S-CL-24B-A01
Price on request
Pneumatic Valves and Manifolds
24 double solenoid valve PROFINET valve terminal · Ref. : C2S-PN-24B-S02
Price on request
Pneumatic Valves and Manifolds
PROFINET valve terminal for 24 double solenoid valves · Ref. : C2S-PN-24B-S03
Price on request
Pneumatic Valves and Manifolds
24-channel EtherNet/IP valve terminal for double solenoid valves · Ref. : C2S-EI-24B-A02
Price on request
No advertising or analytics cookies. A single, strictly necessary cookie is set only if you sign in to your account. Your quote basket and comparison stay in your browser. Details