XB6S-C01SP
Slice-type serial communication module for X-bus

- Operating Temperature
- -20 °C... +60 °C
- Communication interface type
- RS232, RS485, RS422
- Storage Temperature
- -40 °C... +80 °C
- Number of Channels
- 1 channel
Slice-type serial communication module for X-bus
Protocol Gateways, Serial Device Servers & CAN Adapters
The Solidot XB6S-C01SP is a slice-type serial communication module for XB6S series couplers, supporting Modbus master and slave communication and Freeport mode.
Overview. The Solidot XB6S-C01SP is a slice-type serial communication module connected to the X-bus bottom bus and adapted to the manufacturer's XB6S series coupler modules. It provides Modbus master-slave exchanges and Freeport serial communication.
Main characteristics. The module has one channel and supports RS232, RS485 and RS422 interfaces, with baud rates from 1200 bps to 115200 bps, even, odd or no parity, selectable stop bit and 7- or 8-bit word format. Modbus RTU and Modbus ASCII protocols are supported in master and slave modes, along with Freeport modes (request, input, output and input-output). Electrical isolation is included.
Interfaces and connectivity. Connection is made by spring-loaded contacts. Data is transferred over the X-bus backplane at a transmission rate of 6 Mb/s. In slave mode, the Modbus slave station number can be set up to 247. Respond and poll delays are configurable, with a default of 50 ms.
Power and environment. The module is powered at 5 V DC (range 4.5 V to 5.5 V). It operates between -20 °C and +60 °C, can be stored between -40 °C and +80 °C, tolerates 95 % relative humidity non-condensing, and has an IP20 protection rating.
Typical uses. With its RS485 and RS232 interfaces and Modbus support, the module allows serial devices to be connected to a PLC or supervision system in a compact footprint.
Integration. Dimensions are 106.4 x 25.7 x 72.3 mm and weight is 90 g, which simplifies integration into a slice-type assembly.}
No published question about this part yet. Questions are reviewed before publication.
Every characteristic recorded for XB6S-C01SP, with where it comes from. Use the filters to find one quickly.
| Characteristic | Value |
|---|---|
| Dimensions | 106.4 x 25.7 x 72.3 mm |
| Baud rate | 1200 bps... 115200 bps |
| Communication interface type | RS232, RS485, RS422 |
| Communication mode | 0: No selection; 1: Modbus RTU master; 2: Modbus RTU slave; 3: Modbus ASCII master; 4: Modbus ASCII slave; 5: FP_Request (Free port Request mode); 6: FP_Input_Output (Free port input/output mode); 7: FP_Input (Free port input mode); 8: FP_Output (Free port output mode) |
| Communication Protocol | Modbus RTU, Modbus ASCII, Freeport |
| Connection Method | Spring-loaded contact |
| Data transmission medium | X-bus backplane bus |
| Electrical isolation | Yes |
| Modbus slave station number | .. 247 (valid in slave mode) |
| Number of Channels | 1 channel |
| Operating Temperature | -20 °C... +60 °C |
| Parity | 0: No parity; 1: Odd parity; 2: Even parity |
| Poll Delay | 5... 3000 (default 50 ms) |
| Power | 5 V DC (4.5 V... 5.5 V) |
| Protection rating | IP20 |
| Relative humidity | 95 %, non-condensing |
| Respond Timeout | 5... 3000 (default 50 ms) |
| Serial Port Baud Rate | 0: 1200 bps; 1: 2400 bps; 2: 4800 bps; 3: 9600 bps; 4: 19200 bps; 5: 38400 bps; 6: 57600 bps; 7: 115200 bps |
| Slave Respond Delay | 0... 3000 (default 50 ms) |
| Stop Bit | 0: 1 bit; 1: 2 bits |
| Storage Temperature | -40 °C... +80 °C |
| Transmission Rate | 6 Mb/s |
| Weight | 90 g |
| Word Format | 0: 8 bits; 1: 7 bits |
No specification matches.
Last verification : 2026-11-03
Official documents and the technical data recorded for XB6S-C01SP. For a missing document or a specific revision, our experts send it to you.
The Solidot XB6S-C01SP is a slice-type serial communication module for XB6S series couplers, supporting Modbus master and slave communication and Freeport mode.
| Parameter | Value |
|---|---|
| Dimensions | 106.4 x 25.7 x 72.3 mm |
| Baud rate | 1200 bps... 115200 bps |
| Communication interface type | RS232, RS485, RS422 |
| Communication mode | 0: No selection; 1: Modbus RTU master; 2: Modbus RTU slave; 3: Modbus ASCII master; 4: Modbus ASCII slave; 5: FP_Request (Free port Request mode); 6: FP_Input_Output (Free port input/output mode); 7: FP_Input (Free port input mode); 8: FP_Output (Free port output mode) |
| Communication Protocol | Modbus RTU, Modbus ASCII, Freeport |
| Connection Method | Spring-loaded contact |
| Data transmission medium | X-bus backplane bus |
| Electrical isolation | Yes |
| Modbus slave station number | .. 247 (valid in slave mode) |
| Number of Channels | 1 channel |
| Operating Temperature | -20 °C... +60 °C |
| Parity | 0: No parity; 1: Odd parity; 2: Even parity |
| Poll Delay | 5... 3000 (default 50 ms) |
| Power | 5 V DC (4.5 V... 5.5 V) |
| Protection rating | IP20 |
| Relative humidity | 95 %, non-condensing |
| Respond Timeout | 5... 3000 (default 50 ms) |
| Serial Port Baud Rate | 0: 1200 bps; 1: 2400 bps; 2: 4800 bps; 3: 9600 bps; 4: 19200 bps; 5: 38400 bps; 6: 57600 bps; 7: 115200 bps |
| Slave Respond Delay | 0... 3000 (default 50 ms) |
| Stop Bit | 0: 1 bit; 1: 2 bits |
| Storage Temperature | -40 °C... +80 °C |
| Transmission Rate | 6 Mb/s |
| Weight | 90 g |
| Word Format | 0: 8 bits; 1: 7 bits |
Points to check before using XB6S-C01SP in a design. They are derived from the recorded characteristics, not from the manufacturer's application circuits.
| Power | 5 V DC (4.5 V... 5.5 V) |
Check the exact pin assignment and the application circuit in the datasheet, or ask our experts.
Answers to the questions that the recorded characteristics of XB6S-C01SP can answer. A question is not asked when nothing is recorded to answer it.
Yes — recorded under "Communication interface type": RS232, RS485, RS422.
Yes — recorded under "Communication interface type": RS232, RS485, RS422.
Yes — recorded under "Communication mode": 0: No selection; 1: Modbus RTU master; 2: Modbus RTU slave; 3: Modbus ASCII master; 4: Modbus ASCII slave; 5: FP_Request (Free port Request mode); 6: FP_Input_Output (Free port input/output mode); 7: FP_Input (Free port input mode); 8: FP_Output (Free port output mode).
-20 °C... +60 °C (source: Operating Temperature).
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
Slice-type serial communication module for X-bus


1 port RS485 Modbus gateway xprop

Modbus MQTT Gateway

Describe your application and constraints in a request.
What is recorded about the regulatory status and the life of this part.
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
| Current status | Status not stated |
| Key dates | Not recorded |
| Manufacturer part number | XB6S-C01SP |
| Manufacturer | Solidot |
Protocol Gateways, Serial Device Servers & CAN Adapters
Wireless LAN Modbus gateway, IEEE 802.11b/g · Ref. : SMG-5400
Price on request
Protocol Gateways, Serial Device Servers & CAN Adapters
Integrated M2M Gateway with OPC UA, 4G LTE and CNC · Ref. : CPS-MG341G5-ADSC1-931
Price on request
Protocol Gateways, Serial Device Servers & CAN Adapters
USB/RS-232 to CAN-bus protocol converter · Ref. : PRO_VIEW-99
Price on request
Protocol Gateways, Serial Device Servers & CAN Adapters
Profinet to Modbus RTU gateway with DIN-rail mounting · Ref. : PN1-D11PM
Price on request
No advertising or analytics cookies. A single, strictly necessary cookie is set only if you sign in to your account. Your quote basket and comparison stay in your browser. Details