The Star Charge Nereus is a liquid-cooled rectifier and power cabinet, the core equipment for high-power DC fast charging stations, with 720 kW output.
AC Input Current1100A
Output Current2400A
Dimensions(WxHxD)2000*2100*950 mmm
IP ratingIP55
Output voltage150-1000V DC
EVSE CoolingLiquid-cooling (ethylene glycol)
Product overview
Star Charge Nereus 720 kW. DC power cabinet for fast charging — The Star Charge Nereus is a liquid-cooled rectifier and power cabinet, the core equipment of high-power DC fast charging stations. It delivers 720 kW output power, with an output voltage of 150 to 1000 V DC and an output current of 2400 A.
Main characteristics. Compact cabinet measuring 2000 × 2100 × 950 mm, designed for long service life and maintenance-free operation. Liquid cooling with ethylene glycol provides uniform thermal distribution, and the conversion module reaches an efficiency of ≥ 97%, for a system efficiency of ≥ 96%.
Power supply and environment. Three-phase 400 Vac ±15% input, 50/60 Hz, with an AC input current of 1100 A. IP55 protection overall, IP65 for the component bay, and IK10 impact rating.
Typical uses. Power cabinet for fast charging stations. It is compatible with both liquid-cooled and air-cooled charging terminals, and the 720 kW model supports up to 18 user-unit ports per power cabinet.
Integration. The EC centrifugal fan with stepless speed regulation and the recirculating liquid cooling loop keep noise low, with a noise level as low as 55 dB. Available on quotation from Atlas Electronics.
The Star Charge Nereus is a liquid-cooled rectifier and power cabinet, the core equipment for high-power DC fast charging stations, with 720 kW output.
AC Input Current1100A
Output Current2400A
Dimensions(WxHxD)2000*2100*950 mmm
IP ratingIP55
Output voltage150-1000V DC
2. Datasheet extract (recorded values)
Parameter
Value
IP rating
IP55
Output voltage
150-1000V DC
AC Input Current
1100A
AC input voltage
400Vac±15%, three-phase, 50/60Hz, 2 x (L1+L2+L3+N+PE)
Dimensions(WxHxD)
2000*2100*950 mmm
EVSE Cooling
Liquid-cooling (ethylene glycol)
IK Rating
IK10
Output Current
2400A
Output power
720kW
Applications and use cases
Architectures in which NEREUS can play a role, derived from its category. This is not a compatibility statement: check the specifications against your requirements.
Solar production, storage and charging points on one site are often managed separately. Inverters, batteries, MPPT controllers, meters and chargers form a local energy system that shares production between users
To check
Regulatory framework for collective self-consumption in the country
Energy management system steering storage and charging
Metering accuracy for sharing between participants
Associated system blocks
ProductionStorageMeteringCharging
Need a complete solution?