STH-3~8KTL-LS – Single-phase low-voltage hybrid inverter 3 to 8 kW

Single-phase low-voltage hybrid inverter 3 to 8 kW

Grid-Tied Solar Inverters

  • 3–8 kW
  • 40–60 V Low Voltage
  • Single-phase
  • Up to 2 MPPTs
Manufacturer part number
HYBRID-INVERTERS
Manufacturer
Sunways
Power range
3–8 kW
Battery System
40–60 V Low Voltage

Sunways single-phase hybrid inverter rated 3 to 8 kW for residential solar systems with low-voltage battery storage and backup power during grid outages.

Product overview

Overview. The Sunways STH-3~8KTL-LS is a single-phase hybrid inverter from the STH-3~8KTL-LS series, designed for residential solar-plus-storage and small commercial installations. It integrates photovoltaic generation, battery storage, the grid and backup loads into a single energy system.

Main characteristics. Power range of 3 to 8 kW, single-phase grid type, 40 to 60 V low-voltage battery system and up to 2 MPPTs to minimise string mismatch and shading losses on roofs with complex orientations.

Energy management. Storage of surplus solar energy for use at night, time-of-use scheduling that charges during off-peak hours and discharges during peak hours, and export limitation to meet anti-backflow or export-power requirements.

Backup and inductive load start-up. Backup output provides power for critical loads during power cuts, with surge capacity that supports the start-up of inductive loads such as air conditioners and water pumps.

Monitoring and expansion. Cloud monitoring supports remote monitoring and fault diagnosis, and parallel operation increases system power for future capacity expansion.

Typical uses. Solar self-consumption with storage and backup for homes and small commercial sites using a low-voltage battery. Available on quotation from Atlas Electronics.

See all specifications

Highlights

  • Battery System: 40–60 V Low Voltage
  • Complex roof orientation — Multiple MPPTs: Minimises string mismatch and shading losses.
  • Export to the grid is not permitted — Export Limitation: Meets anti-backflow or export-power limitation requirements.
  • Frequent power cuts — Backup Output: Provides backup power for critical loads.
  • Grid type: Single-phase
  • High inrush current from air conditioners and water pumps — Surge Capacity: Enhances the system’s ability to handle inductive load start-up.

Typical applications

Derived from the part category, not a compatibility statement.

See also

Technical questions

Ask a question

No published question about this part yet. Questions are reviewed before publication.

Request a quote