FMX300 – Compact electromagnetic flowmeter with temperature and pressure

Compact electromagnetic flowmeter with temperature and pressure

Electromagnetic Flow Meters

  • M12-4 pin connector
  • <5W
  • (-40~ 80) ℃
  • ±0.5%
Manufacturer part number
02290
Manufacturer
Supmea
Electrical Interface
M12-4 pin connector
Power consumption
<5W

The Supmea FMX300 is a compact electromagnetic flowmeter that measures flow, temperature and, optionally, pressure of a conductive liquid. It suits data center cooling loops.

Product overview

Overview. The Supmea FMX300 is a compact electromagnetic flowmeter (magmeter) designed to measure the flow of conductive liquids. It combines flow, temperature and optional pressure measurement in one device and suits data center cooling loops, CDU systems and chiller circuits.

Main characteristics. Flow accuracy of ±0.5%, repeatability of ±0.16%, temperature accuracy of ±0.5 ℃ and pressure accuracy of ±8 kPa. Nominal diameters from DN6 to DN65. Electrical conductivity of at least 2 μS/cm. The measuring tube has no moving or obstructive parts, with zero pressure loss.

Interfaces and connectivity. 4-20 mA output (load resistance ≤ 500 Ω), pulse output with adjustable pulse equivalent and pulse width from 1 ms to 1000 ms, RS485 interface with MODBUS-RTU protocol and IO-Link. Electrical connection through an M12-4 pin connector.

Power and environment. Power supply of 18 to 36 VDC, power consumption below 5 W. Protection level IP67. Ambient temperature of -25 to 75 ℃, storage temperature of -40 to 80 ℃, relative humidity of 5% to 90%. Medium temperature of -40 to 90 ℃ in the standard type and -40 to 125 ℃ in the high temperature type. Process pressure of -0.1 to 4.0 MPa without pressure sensor, and 0 to 1.6 MPa with pressure sensor.

Typical uses and integration. With its RS485 output in Modbus-RTU and IO-Link, the FMX300 can be connected to a PLC or supervision system to monitor flow and temperature continuously. Three internal totalizers (forward flow, reverse flow and net total flow) help track volumes.

See all specifications

Highlights

  • Ambient temperature: (-25 ~ 75) ℃
  • Communication: 4–20 mA, pulse, RS485 Modbus-RTU and IO-Link
  • Electrical conductivity: ≥2 μS / cm
  • Electrical Interface: M12-4 pin connector
  • Flow accuracy: ±0.5%
  • Integrated Measurement: Flow, temperature and optional pressure

See also

Technical questions

Ask a question

No published question about this part yet. Questions are reviewed before publication.