02298
Pressure-resistant turbidity sensor for water

- Operating Temperature
- -5 to 45 °C (no freezing)
- Power consumption
- ≤ 5W
- Communication output
- RS485 output, Modbus-RTU
- detection limit
- 0.005 NTU
Pressure-resistant turbidity sensor for water
90° laser scattering turbidity sensor for online monitoring of water quality. It suits turbidity monitoring of drinking water and process water.
Overview. The Supmea ADU3500 is a pressure-resistant turbidity sensor designed for online measurement of water turbidity. It operates on 90° laser light scattering with a 660 nm laser source and converts the intensity of light scattered by suspended particles into a turbidity value using a pre-calibrated reference table.
Main characteristics. The sensor offers four measurement ranges: 0 to 1 NTU, 0 to 20 NTU, 0 to 100 NTU and 0 to 2000 NTU. The detection limit is 0.005 NTU and the accuracy is 2% or ±0.02 NTU (whichever is greater) on the low and intermediate ranges, and 10% or ±0.5 NTU on the 0 to 2000 NTU range. Repeatability is 1%, zero drift and display stability are both at most 1.5%, and the response time T90 is at most 120 seconds. The recommended inlet flow rate is 500 mL/min, within a range of 100 to 1000 mL/min.
Interfaces and connectivity. The ADU3500 provides an RS485 output using the Modbus-RTU protocol, as well as a 4 to 20 mA transmitter output that can be set to the measurement range of the corresponding parameter.
Power and environment. The sensor runs on 9 to 28 VDC with a power consumption of at most 5 W. It withstands a pressure of up to 0.6 MPa and operates between -5 and 45 °C, without freezing.
Construction. The pressure-resistant flow path limits bubble formation, the sealed structure facilitates water sample recovery, and the self-cleaning optical window extends maintenance intervals. Its compact size eases system integration.
Typical uses. The sensor is intended for online turbidity monitoring of drinking water, tap water, membrane filtered water, swimming pools and surface water.
No published question about this part yet. Questions are reviewed before publication.
Every characteristic recorded for 02298, with where it comes from. Use the filters to find one quickly.
| Characteristic | Value |
|---|---|
| Accuracy | (0~ 1) NTU /(0~20)NTU/(0~100)NTU: 2% or ±0.02NTU (whichever is greater) (0~2000)NTU: 10% or ±0.5NTU (whichever is greater) (Based on formazine primary standard solution at 25°C) |
| Communication output | RS485 output, Modbus-RTU |
| detection limit | 0.005 NTU |
| Detection method | 90°Light Scattering (laser light source) |
| Display Stability | ≤ 1.5% |
| Inlet Flow Rate | 100 - 1000 mL/min (recommended 500 mL/min) |
| Light source | 660nm laser |
| Operating Temperature | -5 to 45 °C (no freezing) |
| Power consumption | ≤ 5W |
| Power supply | (9~28)VDC |
| Range | 0 - 1NTU / 0 - 20 NTU / 0-100 NTU / 0-2000 NTU |
| Repeatability | 1%(Based on Formazin standard solution at 25°C) |
| Response Time (T90) | ≤ 120 seconds |
| Transmitter output | (4 ~ 20) mA can be set to the corresponding parameter measurement range |
| Withstand Pressure | ≤ 0.6 MPa |
| Zero Drift | ≤ 1.5% |
No specification matches.
Last verification : 2026-11-02
Official documents and the technical data recorded for 02298. For a missing document or a specific revision, our experts send it to you.
90° laser scattering turbidity sensor for online monitoring of water quality. It suits turbidity monitoring of drinking water and process water.
| Parameter | Value |
|---|---|
| Accuracy | (0~ 1) NTU /(0~20)NTU/(0~100)NTU: 2% or ±0.02NTU (whichever is greater) (0~2000)NTU: 10% or ±0.5NTU (whichever is greater) (Based on formazine primary standard solution at 25°C) |
| Communication output | RS485 output, Modbus-RTU |
| detection limit | 0.005 NTU |
| Detection method | 90°Light Scattering (laser light source) |
| Display Stability | ≤ 1.5% |
| Inlet Flow Rate | 100 - 1000 mL/min (recommended 500 mL/min) |
| Light source | 660nm laser |
| Operating Temperature | -5 to 45 °C (no freezing) |
| Power consumption | ≤ 5W |
| Power supply | (9~28)VDC |
| Range | 0 - 1NTU / 0 - 20 NTU / 0-100 NTU / 0-2000 NTU |
| Repeatability | 1%(Based on Formazin standard solution at 25°C) |
| Response Time (T90) | ≤ 120 seconds |
| Transmitter output | (4 ~ 20) mA can be set to the corresponding parameter measurement range |
| Withstand Pressure | ≤ 0.6 MPa |
| Zero Drift | ≤ 1.5% |
Points to check before using 02298 in a design. They are derived from the recorded characteristics, not from the manufacturer's application circuits.
| Power consumption | ≤ 5W |
| Power supply | (9~28)VDC |
Check the exact pin assignment and the application circuit in the datasheet, or ask our experts.
Answers to the questions that the recorded characteristics of 02298 can answer. A question is not asked when nothing is recorded to answer it.
Yes — recorded under "Communication output": RS485 output, Modbus-RTU.
Yes — recorded under "Transmitter output": (4 ~ 20) mA can be set to the corresponding parameter measurement range.
Yes — recorded under "Communication output": RS485 output, Modbus-RTU.
-5 to 45 °C (no freezing) (source: Operating Temperature).
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
Pressure-resistant turbidity sensor for water

SUP-PTU300 Turbidity meter

ADU1310 Turbidity sensor for data center

Raw Water 0~10NTU Laser Optical Turbidity Sensor with Display

Describe your application and constraints in a request.
What is recorded about the regulatory status and the life of this part.
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
| Current status | Status not stated |
| Key dates | Not recorded |
| Manufacturer part number | 02298 |
| Manufacturer | Supmea |
Turbidity Sensors
Online turbidity sensor with RS485 and 90-degree optical measurement · Ref. : WQ-TS-4A
Price on request
Turbidity Sensors
Water Turbidity Sensor, RS485 Output, IP68 · Ref. : RK500-07
Price on request
Turbidity Sensors
IoT digital turbidity sensor with infrared scattered light
Price on request
Turbidity Sensors
Flow-through laser turbidimeter for freshwater low turbidity · Ref. : 5NTU
Price on request
No advertising or analytics cookies. A single, strictly necessary cookie is set only if you sign in to your account. Your quote basket and comparison stay in your browser. Details