ADT3100
Suspended Solids / TSS / MLSS Meter, Infrared

- Storage Temperature
- -20~70℃
- Model
- ADT3100
- Operation Temperature
- -15~60℃
- Power supply
- AC:85-500V, 50/60HZ, 5W DC:9-36V
Suspended Solids / TSS / MLSS Meter, Infrared
The Supmea ADT3100 suspended solids meter continuously measures TSS and MLSS concentration by infrared scattered light, with analog outputs, relays and RS485 Modbus communication.
Overview. The Supmea ADT3100 is a suspended solids meter (TSS, MLSS) that measures concentration by the infrared absorption scattered light method, combined with the application of ISO7027. According to the manufacturer, the infrared double scattering light technology is not affected by chroma. A self-cleaning function can be fitted depending on the usage environment.
Main characteristics. The 128 x 64 dot matrix LCD display has LED backlighting. The lower casing is aluminum with powder coating. The unit weighs 1.35 kg and measures 145 x 125 x 162 mm (L x W x H). Its waterproof rating is IP65.
Interfaces and connectivity. The meter provides a three-way analog output of 4-20 mA whose response parameters and corresponding scope are programmable, with a maximum load of 500 ohms. Three relays can be set up, with programmable response parameters and response values. Digital communication uses MODBUS RS485, which transmits real-time measurements.
Power and environment. The power supply accepts AC 85-500 V, 50/60 Hz, 5 W, or DC 9-36 V. The operating temperature range is -15 to 60 °C and the storage temperature range is -20 to 70 °C.
Typical uses. With its RS485 Modbus output, the ADT3100 can be connected to a PLC or a supervision system to monitor sludge and suspended solids.
No published question about this part yet. Questions are reviewed before publication.
Every characteristic recorded for ADT3100, with where it comes from. Use the filters to find one quickly.
| Characteristic | Value |
|---|---|
| Digital Communication | MODBUS RS485 communication function, which can transmit real-time measurements |
| Display | 128 * 64 dot matrix LCD with LED backlight |
| Main Materials | lower casing: Aluminum with powder covering |
| Model | ADT3100 |
| Operation Temperature | -15~60℃ |
| Output | three-way analog output 4-20mA, response parameters and corresponding scope can be programmed Note: the maximum load is 500 ohms |
| Power supply | AC:85-500V, 50/60HZ, 5W DC:9-36V |
| Relay | three-way relay can be set up, and response parameters and response values can be programmed |
| Size | 145*125*162mm L*W*H |
| Storage Temperature | -20~70℃ |
| Waterproof Rate | IP65 |
| Weight | 1.35 KG |
No specification matches.
Last verification : 2026-11-02
Official documents and the technical data recorded for ADT3100. For a missing document or a specific revision, our experts send it to you.
The Supmea ADT3100 suspended solids meter continuously measures TSS and MLSS concentration by infrared scattered light, with analog outputs, relays and RS485 Modbus communication.
| Parameter | Value |
|---|---|
| Digital Communication | MODBUS RS485 communication function, which can transmit real-time measurements |
| Display | 128 * 64 dot matrix LCD with LED backlight |
| Main Materials | lower casing: Aluminum with powder covering |
| Model | ADT3100 |
| Operation Temperature | -15~60℃ |
| Output | three-way analog output 4-20mA, response parameters and corresponding scope can be programmed Note: the maximum load is 500 ohms |
| Power supply | AC:85-500V, 50/60HZ, 5W DC:9-36V |
| Relay | three-way relay can be set up, and response parameters and response values can be programmed |
| Size | 145*125*162mm L*W*H |
| Storage Temperature | -20~70℃ |
| Waterproof Rate | IP65 |
| Weight | 1.35 KG |
Answers to the questions that the recorded characteristics of ADT3100 can answer. A question is not asked when nothing is recorded to answer it.
Yes — recorded under "Digital Communication": MODBUS RS485 communication function, which can transmit real-time measurements.
Yes — recorded under "Digital Communication": MODBUS RS485 communication function, which can transmit real-time measurements.
Yes — recorded under "Digital Communication": MODBUS RS485 communication function, which can transmit real-time measurements.
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
Suspended Solids / TSS / MLSS Meter, Infrared

Turbidity meter

SUP-PTU300 Turbidity meter

ADU1310 Turbidity sensor for data center

Describe your application and constraints in a request.
What is recorded about the regulatory status and the life of this part.
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
| Current status | Status not stated |
| Key dates | Not recorded |
| Manufacturer part number | ADT3100 |
| Manufacturer | Supmea |
Turbidity Sensors
Online turbidity sensor with RS485 and 90-degree optical measurement · Ref. : WQ-TS-4A
Price on request
Turbidity Sensors
Water Turbidity Sensor, RS485 Output, IP68 · Ref. : RK500-07
Price on request
Turbidity Sensors
IoT digital turbidity sensor with infrared scattered light
Price on request
Turbidity Sensors
Flow-through laser turbidimeter for freshwater low turbidity · Ref. : 5NTU
Price on request