TOBD5-63
Residual current circuit breaker with overcurrent protection RCBO 1P+N

- Rated residual operating current |△(mA):
- 10, 30, 100
- Rated Frequency
- 50/60Hz
- Ambient Air Temperature for Storage
- -40°C to +85°C
- Mounting Support
- DIN rail 35mm
Residual current circuit breaker with overcurrent protection RCBO 1P+N
Residual current circuit breaker with overcurrent protection RCBO single-pole plus neutral 1P+N for final circuit protection in distribution, sensitivity of 10, 30 or 100 mA.
Overview. The Tongou TOBD5-63 is a residual current circuit breaker with overcurrent protection RCBO 1P+N for electrical distribution. It provides complete protection of final circuits, with a leakage protection function intended to prevent electric shock accidents.
Main characteristics. Curve code B or C, 6 kA breaking capacity, rated residual operating current of 10, 30 or 100 mA, AC type A network type, Toggie control with local ON/OFF signalling. The overcurrent protection value is fixed and cannot be adjusted.
Power and environment. Rated operational voltage of 110 V, 196 V/253 V, 230 V/240 V or 380 V/400 V AC, rated frequency 50/60 Hz. Ambient operating temperature from -5 °C to +60 °C, storage temperature from -40 °C to +85 °C, operating altitude up to 2000 m. Electro-mechanical endurance of 20,000 cycles or more.
Typical uses. Protection of circuits in household, commercial and similar installations, with a 30 mA sensitivity that can serve as a supplementary protection device against electric shock. The product is designed for home installation and non-professional operation, with no maintenance required.
Integration. DIN rail mounting 35 mm. Compliant with IEC 61009-1, EN61009 and AS/NZS 61009-1. Installing surge protectors or lightning arresters upstream is recommended.
No published question about this part yet. Questions are reviewed before publication.
Every characteristic recorded for TOBD5-63, with where it comes from. Use the filters to find one quickly.
| Characteristic | Value |
|---|---|
| Ambient Air Temperature for Operation | -5°C to +60°C |
| Ambient Air Temperature for Storage | -40°C to +85°C |
| Breaking Capacity | 6kA |
| Color | Grey |
| Control type | Toggie |
| Curve Code | B, C |
| Device Application | Distribution |
| Electro-mechanical endurance | ≥20,000 cycles |
| Local signaling | ON/OFF indication |
| Mounting Support | DIN rail 35mm |
| Network type | AC Type A |
| Operating Altitude | 2000m |
| Poles Description | 1P+N |
| Rated Frequency | 50/60Hz |
| Rated Operational Voltage | 110V, 196V/253V, 230V/240V, 380V/400V AC |
| Rated residual operating current |△(mA): | 10, 30, 100 |
| Standards | IEC 61009-1, EN61009, AS/NZS 61009-1 |
No specification matches.
Last verification : 2026-11-02
Official documents and the technical data recorded for TOBD5-63. For a missing document or a specific revision, our experts send it to you.
Residual current circuit breaker with overcurrent protection RCBO single-pole plus neutral 1P+N for final circuit protection in distribution, sensitivity of 10, 30 or 100 mA.
| Parameter | Value |
|---|---|
| Ambient Air Temperature for Operation | -5°C to +60°C |
| Ambient Air Temperature for Storage | -40°C to +85°C |
| Breaking Capacity | 6kA |
| Color | Grey |
| Control type | Toggie |
| Curve Code | B, C |
| Device Application | Distribution |
| Electro-mechanical endurance | ≥20,000 cycles |
| Local signaling | ON/OFF indication |
| Mounting Support | DIN rail 35mm |
| Network type | AC Type A |
| Operating Altitude | 2000m |
| Poles Description | 1P+N |
| Rated Frequency | 50/60Hz |
| Rated Operational Voltage | 110V, 196V/253V, 230V/240V, 380V/400V AC |
| Rated residual operating current |△(mA): | 10, 30, 100 |
| Standards | IEC 61009-1, EN61009, AS/NZS 61009-1 |
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
Residual current circuit breaker with overcurrent protection RCBO 1P+N

Residual Current Circuit Breaker with Over-Current RCBO

AC MCB Mini Circuit Breaker C Curve Convenient 4P

DC Mini Circuit Breaker 1200V 63A IEC&AS

Describe your application and constraints in a request.
What is recorded about the regulatory status and the life of this part.
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
| Current status | Status not stated |
| Key dates | Not recorded |
| Manufacturer part number | TOBD5-63 |
| Manufacturer | Tongou |
Miniature Circuit Breakers
UL 489 3-pole miniature circuit breaker, type C curve · Ref. : HCB1U-60/3-1
Price on request
Miniature Circuit Breakers
Fixed metal-enclosed medium voltage switchgear · Ref. : XGN66-12
Price on request
Miniature Circuit Breakers
Modular miniature circuit breaker 1P/2P/3P rated 5 to 60 A · Ref. : UEB1-70
Price on request
Miniature Circuit Breakers
Indoor high-voltage vacuum circuit breaker 40.5 kV · Ref. : WEV-40.5
Price on request
With your consent, we use Google cookies to measure the site’s audience and our advertising. Your quote basket and comparison stay in your browser either way. Details