The Ubiquiti UA-READER LITE is a PoE-powered 13.56 MHz NFC access control reader designed for wall or gang box mounting.
Ambient Operating Temperature-20 to 40° C (-4 to 104° F)
NFC Read Range< 30 mm (1.18'')
Supported Voltage Range44–57V DC
Networking Interface(1) 10/100 MbE port
Max Power Consumption6W
NFC Frequency13.56 MHz
Product overview
Overview. The Ubiquiti UA-READER LITE is an NFC and HF access control reader designed to unlock doors with a card or a handwave.
Main characteristics. It reads ISO 14443A, ISO 14443B and ISO 15693 NFC technologies, NFC Tag 1 to 5 tags and MIFARE Classic, MIFARE Plus, MIFARE Ultralight and MIFARE DESFire families at 13.56 MHz, with a read range below 30 mm. Its polycarbonate enclosure weighs 67 g and measures 94.9 x 40 x 31.1 mm.
Interfaces and connectivity. It provides one 10/100 Ethernet port, Bluetooth 4.1 (BLE 4.1) connectivity, a CAN bus interface and a factory reset button.
Power and environment. It is powered over PoE, with a supply range of 44 to 57 V DC and a maximum power consumption of 6 W. It is rated IP54, operates from -20 to 40 °C and from 5 to 90 % humidity, non-condensing. It can be installed indoors or under a roof eave outdoors.
Typical uses. It integrates with a UniFi Access solution to manage door opening in buildings.
Compliance. It is certified CE, FCC, IC, Anatel, SRRC, UL 294 and CAN/ULC-60839-11-1, grade I.
ISO 14443A, 14443B, 15693 NFC Tag 1, 2, 3, 4, 5 MIFARE Classic MIFARE Plus MIFARE Ultralight MIFARE DESFire
PoE Cabling Requirements
Cat 5e cabling is the minimum performance category recommended. The performance category utilized should match the transmission speed required at the installation site. The minimal conductor gauge permitted to connect between the PSE or power injector and the PD shall be 26 AWG (0.13 mm² ) for patch cords; 24 AWG (0.21 mm² ) for horizontal or riser cable.
Power Method
PoE UL 294 Power-limited Class 2 PSU UL 60950-1/62368-1 LPS/PS2 PSU
Software information
The software version can be checked at <a href="https://unifi.ui.com/" target="_blank" rel="noopener noreferrer">https://unifi.ui.com</a>
Supported Voltage Range
44–57V DC
UL 294 Level
Destructive attack: Level I Line security: Level I Endurance: Level I Standby power: Level I
UL 294 Statement
Compliance with IEEE 802.3 specifications was not verified as part of UL 294. The equipment is intended to comply with the section of the National Electrical Code, ANSI/NFPA 70, Article 725.121, Power Sources for Class 2 and Class 3 Circuits.
UniFi Application Suite
Access
Weatherproofing
IP54
Weight
67 g (2.4 oz)
No specification matches.
Last verification : 2026-11-05
Technical documentation
Official documents and the technical data recorded for UA-READER LITE. For a missing document or a specific revision, our experts send it to you.
ISO 14443A, 14443B, 15693 NFC Tag 1, 2, 3, 4, 5 MIFARE Classic MIFARE Plus MIFARE Ultralight MIFARE DESFire
PoE Cabling Requirements
Cat 5e cabling is the minimum performance category recommended. The performance category utilized should match the transmission speed required at the installation site. The minimal conductor gauge permitted to connect between the PSE or power injector and the PD shall be 26 AWG (0.13 mm² ) for patch cords; 24 AWG (0.21 mm² ) for horizontal or riser cable.
Power Method
PoE UL 294 Power-limited Class 2 PSU UL 60950-1/62368-1 LPS/PS2 PSU
Software information
The software version can be checked at <a href="https://unifi.ui.com/" target="_blank" rel="noopener noreferrer">https://unifi.ui.com</a>
Supported Voltage Range
44–57V DC
UL 294 Level
Destructive attack: Level I Line security: Level I Endurance: Level I Standby power: Level I
UL 294 Statement
Compliance with IEEE 802.3 specifications was not verified as part of UL 294. The equipment is intended to comply with the section of the National Electrical Code, ANSI/NFPA 70, Article 725.121, Power Sources for Class 2 and Class 3 Circuits.
UniFi Application Suite
Access
Weatherproofing
IP54
Weight
67 g (2.4 oz)
Integration
Points to check before using UA-READER LITE in a design. They are derived from the recorded characteristics, not from the manufacturer's application circuits.
1Thermalrated operating range -20 to 40° C (-4 to 104° F) — check it against the installation environment.
Power and communication
Max Power Consumption
6W
Power Method
PoE UL 294 Power-limited Class 2 PSU UL 60950-1/62368-1 LPS/PS2 PSU
Supported Voltage Range
44–57V DC
Check the exact pin assignment and the application circuit in the datasheet, or ask our experts.
Implementation checklist
Thermal : rated operating range -20 to 40° C (-4 to 104° F) — check it against the installation environment.
Applications and use cases
Architectures in which UA-READER LITE can play a role, derived from its category. This is not a compatibility statement: check the specifications against your requirements.
Answers to the questions that the recorded characteristics of UA-READER LITE can answer. A question is not asked when nothing is recorded to answer it.
1Does it support CAN bus?
Yes — recorded under "CAN/ULC-60839-11-1 Grade": Grade assignment: I.
2Does it include Bluetooth?
Yes — recorded under "Connectivity": BLE 4.1 Ethernet.
3Does it have an Ethernet port?
Yes — recorded under "Connectivity": BLE 4.1 Ethernet.
4What is the operating temperature range?
-20 to 40° C (-4 to 104° F) (source: Ambient Operating Temperature).
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
Device: -30 to 45° C (-22 to 113° F) Display: -10 to 45° C (14 to 113° F) (The display will turn off when the ambient temperature is above/below the display operation temperature, but other functions will remain functional. (Effective after firmware v1.3.28))
Device: -30 to 45° C (-22 to 113° F) Display: -10 to 45° C (14 to 113° F) (The display will turn off when the ambient temperature is above/below the display operation temperature, but other functions will remain functional.)
What is recorded about the regulatory status and the life of this part.
Regulatory compliance
CE, FCC, IC, Anatel, SRRC, UL 294, CAN/ULC-60839-11-1Certifications
Destructive attack: Level I Line security: Level I Endurance: Level I Standby power: Level IUL 294 Level
Compliance with IEEE 802.3 specifications was not verified as part of UL 294. The equipment is intended to comply with the section of the National Electrical Code, ANSI/NFPA 70, Article 725.121, Power Sources for Class 2 and Class 3 Circuits.UL 294 Statement
No advertising or analytics cookies. A single, strictly necessary cookie is set only if you sign in to your account. Your quote basket and comparison stay in your browser. Details