UT278B – Clamp earth resistance tester with 2.4-inch colour LCD

Clamp earth resistance tester with 2.4-inch colour LCD

Installation and Earth Testers

  • 0.000A–60A
  • 1uA
  • 750mA MAX
  • 500 set
Manufacturer part number
UT278B
Manufacturer
UNI-T
Operating Temperature
-10℃ — 50℃; below 80%RH
Current Resolution
1uA

UNI-T UT278B clamp earth resistance tester with a 2.4-inch colour LCD, for checking the grounding of electrical, telecom and industrial installations.

Product overview

Overview. The UNI-T UT278B clamp earth resistance tester is an instrument for measuring ground resistance, designed to check the grounding of electrical installations. It belongs to the UT278B/C/D series, and the UT278B model is the base version.

Measurement functions. The instrument measures ground resistance from 0.00 Ω to 1500 Ω, leakage current and load current up to 40 A, and ground voltage up to 600 V. Clamp measurement allows testing without disconnecting the earth electrode, with a 68 mm jaw. Measurement is performed once per second.

Display and data. A 2.4-inch colour LCD shows the results, with backlight and overload indication "OL". It stores up to 500 measurements, which can be uploaded over USB to be saved or printed, and an alarm function signals threshold exceedance.

Power and environment. The instrument runs on a rechargeable 3.7 V DC lithium battery, with real-time charge display, and switches off automatically after about 15 minutes. It operates between -10 ℃ and 50 ℃ and weighs 975 g including battery.

Safety. It complies with IEC 61010-1, IEC 61010-031 and IEC 61557-1 standards, with CAT III 300 V and CAT IV 150 V ratings, for pollution degree 2. Its withstand voltage is 3700 V RMS between circuit and case.

Applications. It is suitable for measuring grounding resistance in telecommunications, electricity, meteorology, computer rooms, oil fields, power distribution and transmission lines, gas stations, factory grounding grids and lightning rods.

See all specifications

Highlights

  • Accuracy Guaranteed; Temperature Humidity: 23℃±5℃,below 75%rh
  • Alarm Function: √
  • Auto Power Off: Around 15 minutes
  • Backlight: √
  • Current (AC) — 0.000A–40A — 0.000A–50A: 0.000A–60A
  • Current Resolution: 1uA

Good to know before integrating

  • Thermal: rated operating range -10℃ — 50℃; below 80%RH — check it against the installation environment.