VT-SNS-LORA – LoRaWAN wireless temperature and humidity sensor

LoRaWAN wireless temperature and humidity sensor

Temperature Sensor Modules

  • 915MHz, 490MHz;
  • -40℃~+85℃
  • -40℃~+80℃;
  • 0.01℃;
Manufacturer part number
3258-VTSNSLORALORAWANWIRELESSTEMPERATUREANDHUMIDITYSENSOR
Manufacturer
Vantron
Frequency
915MHz, 490MHz;
Storage
-40℃~+85℃

The Vantron VT-SNS-LORA is a LoRa wireless sensor that measures temperature, humidity, light and motion and transmits the data over a LoRaWAN network.

Product overview

Vantron VT-SNS-LORA. LoRaWAN wireless temperature and humidity sensor. This wireless sensor uses LoRa spread spectrum modulation to measure and transmit environmental data over a LoRaWAN v1.0.3 Class A network.

Measurements. The temperature range is -40 °C to 80 °C with an accuracy of ±0.2 °C between 0 and 65 °C and a resolution of 0.01 °C. Relative humidity is measured from 0% to 100% RH with an accuracy of ±2% between 10% and 90% RH. The sensor also integrates a 3-axis accelerometer (+2g/+4g/+8g/+16g) and an ambient and infrared light sensor.

LoRa radio. Frequencies 915 MHz and 490 MHz, TX power up to 22 dBm in high mode and 15 dBm in low mode, RX sensitivity of -148 dBm at 10.4 kHz and SF 12, spreading factor from 5 to 12, bit rate from 0.013 to 17.4 kbit/s.

Location and power. GNSS receiver compatible with BDS, GPS, GLONASS and Galileo, with an accuracy of 2.5 m. The sensor includes a real-time clock, a USB Type-C port for configuration, debugging and charging, and a rechargeable battery.

Environment. Operating temperature from -40 °C to +80 °C and storage temperature from -40 °C to +85 °C.

Typical uses. Monitoring in smart agriculture, warehousing, food services and cold chain management, where a few sensors can cover large areas thanks to the range and low power consumption of LoRaWAN.

Integration. Raw data is received by Vantron LoRaWAN gateways, then uploaded to the cloud for analysis and control.

See all specifications

Highlights

  • Accuracy: ±0.2°C (0~65°C), max.±0.6°C(outside 0~65°C)
  • RX Sensitivity: -148dBm (at 10.4 kHz, SF 12)
  • Storage: -40℃~+85℃

Typical applications

Derived from the part category, not a compatibility statement.

See also

Technical questions

Ask a question

No published question about this part yet. Questions are reviewed before publication.

Request a quote