Winsen MC101B catalytic sensor for detecting combustible gases such as natural gas, LPG, coal gas, CH4 and C3H8, over a range of 0 to 100%LEL.
Detection range0-100%LEL
Working current(mA)110±10
Storage Environment-20~+70℃ <95%RH
Detection Principlecatalytic combustion
Life span5 years
Linearity≤ 5%
Product overview
Overview. The Winsen MC101B is a catalytic combustion flammable gas sensor measuring from 0 to 100%LEL. It belongs to the environmental and gas sensor range.
Detection principle. A test element and a compensation element form two arms of a bridge. The resistance of the test element rises in the presence of combustible gas, and the bridge output voltage changes in proportion to the concentration. The compensation element corrects for temperature and humidity.
Main characteristics. Sensitivity of 20 to 45 mV, linearity ≤ 5%, response time (90%) ≤ 10 s and recovery time ≤ 30 s. The sensor offers a fast response, good repeatability and good selectivity. Life span of 5 years.
Targets. Combustible gases such as non-industrial natural gas, LPG, coal gas, CH4 and C3H8.
Power and environment. Working voltage of 3.0 ± 0.1 V with a working current of 110 ± 10 mA. Operating range -40 to +70 °C at less than 95%RH; storage range -20 to +70 °C at less than 95%RH.
Package. Standard plastic encapsulation, φ12.2 × 8.5.
Winsen MC101B catalytic sensor for detecting combustible gases such as natural gas, LPG, coal gas, CH4 and C3H8, over a range of 0 to 100%LEL.
Detection range0-100%LEL
Working current(mA)110±10
Storage Environment-20~+70℃ <95%RH
Detection Principlecatalytic combustion
Life span5 years
2. Datasheet extract (recorded values)
Parameter
Value
Characteristics
Bridge output voltage in linear, fast response, good repeatability and selectivity
Detection Principle
catalytic combustion
Detection range
0-100%LEL
Life span
5 years
Linearity
≤ 5%
Measuring range(%LEL)
0~100
Model
MC101B
Recovery Time (90%)
≤ 30s
Response time (90%)
≤ 10s
Sensitivity (mV)
20~45
Sensor Type
Catalytic type
Size
φ12.2×8.5
Standard Encapsulation
Plastic
Storage Environment
-20~+70℃ <95%RH
Target
Combustible gases such as non-industrial natural gas,LPG,coal gas,CH4,C3H8 and so on
Working Conditions
Working voltage:3±0.1V; Working current:110±10mA
Working current(mA)
110±10
Working Environment
-40~+70℃ <95%RH
Working Voltage (V)
3.0±0.1
Applications and use cases
Architectures in which MC101B can play a role, derived from its category. This is not a compatibility statement: check the specifications against your requirements.
Offices and classrooms get stuffy without anyone measuring why. Indoor air quality monitoring places CO2, VOC and particle sensors in the rooms and reports their values through a gateway, so ventilation can be adjusted to real occupancy
To check
Parameters to measure (CO2 alone or CO2, VOC and particles)
Battery-powered sensors or mains-powered sensors with display
Integration with the ventilation control or building management system
Associated system blocks
Air sensorsGateway
Need a complete solution?
Send a request for MC101B and the other parts of your project.
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
What is recorded about the regulatory status and the life of this part.
Regulatory compliance
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
No advertising or analytics cookies. A single, strictly necessary cookie is set only if you sign in to your account. Your quote basket and comparison stay in your browser. Details